Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutPW FY 2018-19 Fleet Vehicle PurchasesAgenda Item No.: 4.g
Meeting Date: January 22, 2019
SAN RAFAEL CITY COUNCIL AGENDA REPORT
Department: Public Works
Prepared by: Bill Guerin
Director of Public Works
City Manager Approval:_________
File No.: 01.14.16
TOPIC: FY 2018-19 FLEET VEHICLE PURCHASES: TWO FIRE ENGINES
SUBJECT: RESOLUTION AUTHORIZING THE CITY MANAGER TO PURCHASE ONE TYPE
1 AND ONE TYPE 6 ENGINE, INCLUDING BUILD-UP AND OUTFITTING, FOR
THE FIRE DEPARTMENT FOR A NOT TO EXCEED AMOUNT OF $900,000.
RECOMMENDATION: Adopt a resolution authorizing the City Manager to purchase one Type 1
and one Type 6 engine, including build-up and outfitting, for the Fire Department, for a not-to-
exceed amount of $900,000.
BACKGROUND: The City of San Rafael’s vehicle fleet consists of 185 vehicles. This includes
passenger cars and trucks, as well as the City’s specialty vehicles supporting the Fire
Department, Police Department, Public Works, and others. In addition to the street-legal
vehicles maintained in the City fleet, the Public Works Vehicle Maintenance and Replacement
Program maintains 66 heavy equipment vehicles, including a backhoe, paint striper, tractors,
and street sweepers. Most City vehicles are utilized by public safety (Police and Fire), followed
by Public Works.
The Department of Public Works annually proposes a list of vehicles that are recommended for
replacement during that fiscal year. The City’s Fleet Management Policy and Procedures
(Attachment 5) outlines the role of the Fleet Manager and various policies around replacement
and repairs (including a commitment to purchase “green” (e.g. hybrid or electric vehicles)
whenever possible). In addition, the Policy and Procedures document suggests a useable life
for fleet vehicles by type. Although the usable life schedule outlined in the Fleet Policy and
Procedures serves as a guide for estimating when replacement should occur, vehicles are not
necessarily replaced in the number of years dictated by this schedule. The decision to replace a
vehicle or other piece of equipment is based on its safety, mechanical condition, repair history
and cost, the department’s operational needs, and available finances. This results in some
vehicle replacements made well after a vehicle’s original anticipated replacement date, and at
times vehicles may also be recommended for replacement before their scheduled replacement
date.
The annual budget for vehicle replacement is set in the Vehicle Replacement Fund (Fund no.
600). On average, $1.2 million in revenue from the City’s General Fund are deposited into
the
____________________________________________________________________________________
FOR CITY CLERK ONLY
File Number: 4-3-800
Council Meeting: 01/22/2019
Disposition: Resolution 14622
SAN RAFAEL CITY COUNCIL AGENDA REPORT / Page: 2
Vehicle Equipment Replacement Fund annually for the purpose of the purchase of new vehicles
and equipment. Since Fiscal Year 2015-16, the following fleet purchases have been approved
by the City Council:
Council Meeting Date Vehicles/Equipment Purchased
March 7, 2016 2 Fire pumper Engines
October 3, 2016 6 Police Patrol Units
7 Public Works vehicles and equipment
1 Parking Services van
June 5, 2017 3 Fire Command Vehicles
3 Public Works Equipment Vehicles (Backhoe, Sweeper, Vacuum
Truck)
1 Parking Enforcement vehicle
October 2, 2017 2 Fire Ambulances
December 18, 2017 3 Public Works Commercial Work Trucks
1 Public Works Utility Truck
1 Police Department Utility Truck
1 Parking Services Utility Truck
1 Fire Department Ambulance
September 17, 2018 3 Police Patrol Units
1 Police Investigation Vehicle
1 Fire Utility Truck
January 22, 2019
(proposed)
2 Fire pumper engines (One Type 1 Engine, One Type 6 Engine)
ANALYSIS: At this time the Public Works and Fire Department are recommending going
forward with the purchase of two fire engines: one Type 1 engine (replacing type 1 engine #97-
03)and one Type 6 engine (replacing type 1 engine #104-02), both of which have passed their
15-year life as recommended on the replacement schedule in the Fleet Management Policy and
Procedures. The current San Rafael Fire engine fleet consists of 6 front line engines and 3
reserve engines.
Front line engines
•Station 51: #108-13 KME Fire Engine (2013)
•Station 52: #111-13 KME Fire Engine (2013)
•Station 54: #104-02 KME Fire Engine (2002) - to be replaced
•Station 55: #97-03 KME Fire Engine (2003) - to be replaced
•Station 56: #35-17 Pierce Engine (2017)
•Station 57: #23-17 Pierce Engine (2017)
Reserve engines:
•Station 51: #OES358 HME Type 1 Engine (2003)
•Station 52: #26-02 KME Fire Engine (2002)
•Station 54: #114-15 Pierce Ladder Truck (2015)
•Station 57: #56-03 KME Fire Engine (2003)
•Station 57: #113-01 KME/Smeal Ladder Truck (2001)
SAN RAFAEL CITY COUNCIL AGENDA REPORT / Page: 3
Summary of Proposed Vehicle/Equipment Purchases
Dept Vehicle to be
replaced
Last
year
replaced
Replace with
(Make/Model)
Price Build up +
outfitting
Purchase
Strategy
Fire Type 1 Engine
(#97-03)
2003 Pierce Type 1 Engine $633,973 $76,027 HGAC
Fire Type 1 Engine
(#104-02)
2001 Dodge Type 6 Engine $138,512 $51,488 State Contract
Total $772,485 $127,515
Grand Total $900,000
With the due purchase of a Fire apparatus, the Fire Department takes the opportunity to re-
evaluate the deployment and engine types utilized in the current fleet and whether the current
fleet is meeting the department’s and community’s fire prevention and safety needs. In this
case, with two Type 1 engines due for replacement, the Fire Department has determined that
one of the replacements should be with a full Type 1 engine, but one of the Type 1 engines
should be replaced with a more compact and nimbly designed, as well as less expensive, Type
6 engine.
A Type 6 engine is a commercial chassis four-wheel drive pick-up truck outfitted as a firefighting
apparatus, with a 300-gallon water tank, fire pump, and necessary equipment. Type 6 engines
are designed for quick attack wildland fires, and can be utilized for emergency response on
narrow, steep roads in hard to reach areas such as Southern Heights, Upper Fremont, and
Sunny Oaks. These vehicles have been very effective in recent fires throughout California that
require quick and responsive access. There are also significant cost savings associated with the
purchase of a Type 6 engine in place of a Type 1 engine.
A Type 1 engine is a traditional full-size firefighting apparatus engine. Pierce Manufacturing has
been the Marin County standard for fire engines since the 1990’s and the Department has opted
for Pierce engines in the last few rounds of engine purchases, including most recently in 2016,
when the Department purchased two Pierce Manufacturing Type 1 engines. Consistency in the
fleet is important to build familiarity with the equipment, and Pierce equipment is preferred for its
quality, durability and reliability.
The Type 1 Engine will be purchased through a cooperative purchasing agreement through the
Houston-Galveston Area Council (HGAC). The lead contracting agency who executed the
competitive bidding process relating to this cooperative purchasing agreement is the Public
Procurement Authority. The Golden State Fire Apparatus is the vendor that the engine will be
purchased directly from. The Type 6 engine will be purchased through the State Contract,
negotiated and administered by the State of California General Services Agency. The State
Contract is a cooperative purchasing program that local governments (and other government
agencies) are able to “piggyback” on with their own purchases. The prices for vehicles and
equipment in the statewide contract are awarded to the dealership which bids the lowest price
for that make/model. The City’s Purchasing Policy allows for the utilization of cooperative
purchasing programs:
Cooperative purchasing programs. Purchases of supplies, material, equipment or
services and sales of surplus property made under a cooperative purchasing
program, such as by utilizing purchasing agreements maintained by the United
States government or any agency or division thereof, the State of California,
SAN RAFAEL CITY COUNCIL AGENDA REPORT / Page: 4
County of Marin, or other public agencies, are exempt from the competitive
bidding requirements of this chapter. To the extent possible, cooperative
purchases joined will be competitively awarded, and documentation as to the
advantage of the cooperative purchase will be retained.
(SRMC 2.55.100(e)). After this purchase, the fire department fire apparatus and engine fleet will
be in good condition, with four Type 1 engines in reserve with at least 10 years of life left.
FISCAL IMPACT: There are sufficient funds available in the Vehicle Replacement Fund (fund
no. 600) for the purchases totaling $900,000. The following tables summarize the costs
associated with each engine:
Type 1 Engine (1)
Pierce Enforcer Type 1 Engine Golden State Fire Apparatus $633,973
Equipment and Outfitting Various $64,988
Contingency $11,039
TOTAL $710,000
Type 6 Engine (1)
Dodge 5500 XLT Cab and Chassis Dodge $72,125
Build up and pump apparatus Cascade Fire Equipment $66,386
Equipment and Outfitting Various $41,405
Contingency $10,083
TOTAL $190,000
All City departments pay into the Vehicle Replacement Fund each year as an internal service
charge. The amount they pay is based on the number and dollar value of vehicles/equipment
the Department utilizes and is amortized over the anticipated useful life.
Per the City’s Purchasing Policy, all retired City vehicles will be competitively bid and sold at
auction or to other agencies. Any income received from the sale of the vehicles will be
deposited back into the Vehicle Replacement Fund towards for future vehicle purchases.
OPTIONS:
1.Approve the resolution authorizing the City Manager to purchase one Type 1 engine
and one Type 6 engine for a not-to-exceed amount of $900,000.
2.Direct the Department of Public Works to modify the proposed purchases.
3.Direct the Department of Public Works to withhold the proposed purchases. This option
may have additional costs associated with vehicle/equipment rentals if the current
vehicles or equipment experience mechanical failure.
RECOMMENDED ACTION: Adopt a resolution authorizing the City Manager to purchase one
Type 1 and one Type 6 engine, including build-up and outfitting, for the Fire Department, for a
not-to-exceed amount of $900,000.
ATTACHMENTS:
1.Resolution
2.HGAC quote – Pierce Enforcer Type 1 Engine
3.State contract quote – Type 6 Engine
SAN RAFAEL CITY COUNCIL AGENDA REPORT / Page: 5
4.Cascade Fire Equipment Company Quote – Type 6 Engine Build up and pump body
5.City Fleet Management Policy and Procedures
1
RESOLUTION NO. 14622
RESOLUTION OF THE SAN RAFAEL CITY COUNCIL AUTHORIZING THE CITY
MANAGER TO PURCHASE ONE TYPE 1 AND ONE TYPE 6 ENGINE, INCLUDING BUILD-
UP AND OUTFITTING, FOR THE FIRE DEPARTMENT FOR A NOT-TO-EXCEED AMOUNT
OF $900,000.
WHEREAS, San Rafael’s various departments operate a fleet of 185 vehicles; and
WHEREAS, the management and replacement of the City’s fleet of vehicles and equipment is
governed by the guidelines set forth in San Rafael’s Fleet Management Policies and Procedures
document issued September 6, 2012; and
WHEREAS, two existing Type 1 fire engines have reached the end of their useful life and their
term set forth on the replacement schedule in the City’s Fleet Management Policies and Procedures, and
several are notably costing the City more to repair and maintain than to replace; and
WHEREAS, the said engines serve vital fire prevention functions to City services; and
WHEREAS, the Fire Department and the Department of Public Works is recommending the
purchase of two fire engines, one Type 1 Engine and one Type 6 Engine, for the Fire Department; and
WHEREAS, the City Vehicle Maintenance program also purchases, installs, and maintains
equipment on City fleet vehicles; and
WHEREAS, there is sufficient fund balance in the City’s Vehicle Replacement Fund (#600);
and;
NOW, THEREFORE BE IT RESOLVED that the City Council of the City of San Rafael
authorizes the City Manager to execute the purchase of two fire engines for the Fire Departments, as
described in the Staff Report submitted to the City Council and incorporated herein, in accordance with
the guidelines set forth in San Rafael’s Fleet Management Policies and Procedures, issued on September
6, 2012. Funds shall be appropriated to the Vehicle Replacement budget accordingly in order to support
these purchases totaling $900,000.
I, LINDSAY LARA, Clerk of the City of San Rafael, hereby certify that the foregoing Resolution was
duly and regularly introduced and adopted at a regular meeting of the City Council of said City held on
Tuesday, the 22nd day of January 2019 by the following vote, to wit:
AYES:
NOES:
ABSENT:
COUNCILMEMBERS: Bushey, Colin, Gamblin & Mayor Phillips
COUNCILMEMBERS: None
COUNCILMEMBERS: McCullough
______________________________
LINDSAY LARA, City Clerk
PROPOSAL PREPARED FOR
San Rafael Fire Department
Pierce Manufacturing, Inc.
Enforcer 1500 GPM Pumper
December 17.2018
—� — OW
SALES CONSULTANT
Daron Wright
Golden State Fire Apparatus, Inc.
7400 Reese Road
Sacramento, CA 95828
916.330.1638 Office
209.993.6972 Cell
daronPgoldenstatefire.com
PARTS, SERVICE & SUPPORT
Golden State Emergency Vehicle Service, Inc.
7400 Reese Road
Sacramento, CA 95828
916.330.1638 Office
Parts(&goldenstatefire.com
PROPOSAL PREPARED FOR -
San Rafel Fire Department
1039 C Street
San Rafael, CA 94901
We hereby propose and agree to furnish, after your acceptance of this proposal and the proper execution by the SAN RAFAEL
FIRE DEPARTMENT, hereinafter called "Customer" and an officer of Golden State Fire Apparatus, Inc., hereinafter called
"GSFA", the following fire apparatus and equipment, hereinafter called "Product":
A One (1) Pierce Manufacturing, Enforcer 1500 GPM Pumper 603,066.65
B Discount For 100% Pre -Payment at Time of Order (21,449.78)
SUBTOTAL ` 581,616.87
9.00% State Sales Tax 52,345.52
�• California Tire Fee 10.50
PROPOSAL SUMMARY
This proposal includes the following items in accordance with the specifications hereto attached:
■ Fire apparatus and equipment
• 100% performance bond
• Factory final inspection trip
• Pre -delivery inspection/services by GSFA
PRODUCT COMPLETION
■ Delivery to GSFA service center in Sacramento
■ Final delivery from service center to Customer
• Demonstration and familiarization of the Product
• California Tire Fee
Product shall be built in accordance with the specifications hereto attached, delays due to acts of God, strikes, war, or
intentional conflict, failures to obtain chassis, materials, unusual weather conditions or other causes beyond GSFA's control not
preventing, within approximately 285 to 315 CALENDAR DAYS after receipt of this order and the acceptance thereof at our
Sacramento, California office. Within thirty (30) calendar days after receipt of this order and acceptance thereof, GSFA shall'
submit to Customer a production schedule including tentative pre -construction conference, final inspection and final delivery
dates.
DELIVERY LOCATION
Product shall be shipped in accordance with the specifications hereto attached and be delivered to you at SAN RAFAEL
CALIFORNIA. Proof of insurance must be demonstrated by the Customer to GSFA prior to transferring of the Product(s).
Page 2 of 3
ACCEPTING THIS PROPOSAL
In the event Customer wishes to purchase the Product described in this Proposal and the attached specifications, then, prior to the expiration
date listed on page 2 of this Proposal, Customer shall sign and return this Proposal. Thereafter, GSFA and Customer will endeavor to enter into
a purchase agreement incorporating this Proposal and including additional terms (a "Purchase Agreement"). If Customer returns a signed copy
of this Proposal alone, GSFA will send Customer its form of Purchase Agreement for Customer's review and signature. If Customer desires to
use its standard form of purchase order as the Purchase Agreement, then Customer should return a signed copy of this Proposal along with a copy
of such purchase order. All purchase orders shall be made out to GSFA. GSFA will review such purchase order and contact the Customer
regarding any required revisions. Only upon a full execution of a Purchase Agreement shall GSFA and Customer be obligated to purchase and
sell the Product set forth in this Proposal.
TERMS AND CONDITIONS
The following Terms and Conditions are hereby made part of this Proposal:
1. Payment Terms, 100% Pre -Payment at Time of Order -
Customer shall pay the amount listed on page one of this
Proposal, which includes: (i) the total price for the Product (the
"Purchase Price"), (ii) the estimated state sales tax on the Product,
and (iii) the California tire fee (together with the Purchase Price
and estimated state sales tax, the "Grand Total") within fifteen
(15) calendar days from the date on which the Purchase
Agreement is fully executed. The proposed delivery timeframe for
the Product, which is outlined on page one of this Proposal, shall
not begin until full payment of the Grand Total is received. In the
event Customer does not pay GSFA the Grand Total in the
timeframe set forth in this Section 1, GSFA may, in its sole
discretion, cancel the Purchase Agreement entered into between
the parties.
2. Multiple Unit Purchase - If the Purchase Price includes pricing
for multiple units, the price stated on this Proposal shall only be
valid if the quantity of Products being proposed are purchased at
the same time, pursuant to the same Purchase Agreement.
3. Stock/ Demo Units - If applicable, any stock/demo units,
including those identified by this Proposal, are available for sale
on an as -is, first-come and first served -basis. Regardless of this
Proposal, the first Customer to enter into a Purchase Agreement
identifying any such stock/demo unites shall obtain said units.
4. Order Changes - The Customer may request that GSFA
incorporate a change to the Product or the Specifications for the
Product by delivering a written change order to GSFA, which shall
include a description of the proposed change sufficient to permit
GSFA to evaluate the feasibility of such change (a "Change
Order'). GSFA will provide Customer a written response (a
"Response") stating (i) whether GSFA will accommodate such
Change Order (which GSFA may decide in its sole and absolute
discretion) and (ii) the terms of the modification to the order,
including any increase or decrease in the Purchase Price resulting
from such Change Order, and any effect on production scheduling
or Delivery resulting from such Change Order. Customer shall
have seven (7) days after receipt of the Response to notify GSFA
as to whether Customer desires to make the changes GSFA has
approved in the Response. In the event Customer counter -signs
GSFA's Response, Customer shall pay the increase (or be
refunded the decrease) in the Purchase Price prior to final
delivery to Customer location.
5. Force Majeure - GSFA shall not be responsible nor deemed to
be in default on account of delays in performance due to causes
which are beyond GSFA's and manufacturer's control and which
make GSFA's performance impracticable, including but not limited
to wars, insurrections, strikes, riots, fires, storms, floods, other
acts of nature, explosions, earthquakes, accidents, any act of
government, delays in transportation, inability to obtain
necessary labor supplies or manufacturing facilities, allocation
regulations or orders affecting materials, equipment, facilities or
completed products, failure to obtain any required license or
certificates, acts of God or the public enemy or terrorism, failure
of transportation, epidemics, quarantine restrictions, failure of
vendors (due to causes similar to those within the scope of this
clause) to perform their contracts or labor troubles causing
cessation, slowdown, or interruption of work.
6. Cancellation/ Termination - In the event Customer and GSFA
enter into a Purchase Agreement and Customer thereafter
cancels or terminates the Purchase Agreement, GSFA will charge
a cancellation fee as follows: (a) 10% of the Purchase Price after
order is accepted and entered by GSFA; (b) 20% of the Purchase
Price after completion of the pre -construction phase of the order
process; and (c) 50% of the Purchase Price after the requisition of
any materials or commencement of any manufacturing or
assembly of the Product by either GSFA or the manufacturer of
the Product. The tier of cancellation fee applicable to any
cancellation shall be in the sole and absolute discretion of GSFA.
7. State Sales Tax - Customer shall be responsible for the cost of
state sales tax associated with, or attributable to the Product. The
taxes owed by Customer for the Product is subject to adjustment
for the applicable state sales tax rate in effect when the Product is
delivered to the Customer. Therefore, the sales tax will be
increased or decreased at the time of delivery if a change in the
sales tax rate has occurred, in which case Customer shall pay
GSFA (or be refunded by GSFA) the applicable change in sales tax.
8. Proposal Expiration - After the Expiration Date shown on page
one of this Proposal, Customer shall require GSFA's written
consent to accept this Proposal.
9. Governing Law - This Proposal is to be governed by and under
the laws of the state of California.
Thank you for providing Golden State Fire Apparatus, Inc. with the opportunity to provide this proposal. If you have any questions regarding
the options presented or need additional options, please contact me.
Sincerely, 1. Jim SC hu tZ authorized representative of
SAN RAFAEL FIRE DEPARTMENT agrees to purchase the proposed Product(s) and agree to
the terms and co 'tions of this pas I and the s ications hereto attached.
Daron Wrightr SIGNATURE:
Golden State Fire Apparatus, Inc.
TITLE: Cit Mana er_, Cit f DATE:
San Rafael
7400 Reese Road, Sacramento, CA 95828 1 Office 916.330.1638 1 Fax 916.330.1649 Page 3 of 3
CONTRACT ROUTING FORM
INSTRUCTIONS: Use this cover sheet to circulate all contracts for review and approval in the order shown below
TO BE COMPLETED BY INITIATING DEPARTMENT PROJECT MANAGER
Contracting Department: DPW
Project Manager: TS
Extension: 3354
Project Name: Fire engine purchase
Contractor's Contact: Kyle Hamilton - SRFD
Contact's Email: kyle.hamilton@citvofsanrafael.ore
COMPLETED DATE I REVIEWER (Initials)
1/15/2018
1/15/2018
1 222018
TS
TS
TS
RESPONSIBLE
Piro Council upprorul required for 1'rn/ceciunal Sen icrs : t,{reernrnle and
tep
DEPARTMENT
DESCRIPTION
5
Project Manager
a. Email PINS Introductory Notice to Contractor
b. Email Contract (in Word) +£ attachments to City Attorney c/o
PRIN I
I
Project Manager
Laraine.Gittens@cityot'sanrafael.org
cityofsanrafael.org
6
Project Manager
a. Review, revise and comment on draft agreement and return to Project
7
City Attorney
Manager
b. Confirm insurance requirements. create Job on PINS. send PINS
Review and approve insurance in PINS, and bonds (for public works
2
City Attorney
insurance notice to contractor.
City
Approval of final agreement form to send to contractor. (Provide Dept.
3
Department Director
Director Financial Sunaaan' ii'/Agreement)
Forward three (3) originals of final agreement to contractor for their
4
Project Manager
signature.
When necessary, contractor -signed agreement agendized for Council
COMPLETED DATE I REVIEWER (Initials)
1/15/2018
1/15/2018
1 222018
TS
TS
TS
Piro Council upprorul required for 1'rn/ceciunal Sen icrs : t,{reernrnle and
pru•chuses o/',Roods and sc•rrices drat exceed 875.000 and /in• Public Works
5
Project Manager
t_onn•ucts that exceed S175,000(1aner dote of Council Meeting)
CONTIN.L.111 ROUTING PROCESS WITH HARD COPY
PRIN I
Forward signed original agreement to City Attorney with printed copy of
6
Project Manager
this routine form
7
City Attorney
Review and approve hard copy of signed agreement
Review and approve insurance in PINS, and bonds (for public works
8
City Attorney
contracts)
City
9
Manager/Mayor
Agreement executed by Council authorized official
Attest signatures, retains original agreement and forwards copies to project
JI
City Clerk
manager
Project Manager
Forward Final Copy to Contractor
COMPLETED DATE I REVIEWER (Initials)
1/15/2018
1/15/2018
1 222018
TS
TS
TS
PROPOSAL PREPARED FOR
San Rafael Fire Department
Pierce Manufacturing, Inc.
Enforcer 1500 GPM Pumper
December 17, 2018
SALES CONSULTANT
Daron Wright
Golden State Fire Apparatus, Inc.
7400 Reese Road
Sacramento, CA 95828
916.330.1638 Office
209.993.6972 Cell
daron@goldenstatefire.com
PARTS, SERVICE & SUPPORT
Golden State Emergency Vehicle Service, Inc.
7400 Reese Road
Sacramento, CA 95828
916.330.1638 Office
parts@goldenstatefire.com
Page 2 of 3
www.goldenstatefire.com
7400 Reese Road
Sacramento, CA 95828
Office 916.330.1638
Fax 916.330.1649
PROPOSAL PREPARED FOR:
San Rafel Fire Department
1039 C Street
San Rafael, CA 94901
We hereby propose and agree to furnish, after your acceptance of this proposal and the proper execution by the SAN RAFAEL
FIRE DEPARTMENT, hereinafter called “Customer” and an officer of Golden State Fire Apparatus, Inc., hereinafter called
“GSFA”, the following fire apparatus and equipment, hereinafter called “Product”:
PROPOSAL SUMMARY
This proposal includes the following items in accordance with the specifications hereto attached:
Fire apparatus and equipment
100% performance bond
Factory final inspection trip
Pre-delivery inspection/services by GSFA
Delivery to GSFA service center in Sacramento
Final delivery from service center to Customer
Demonstration and familiarization of the Product
California Tire Fee
PRODUCT COMPLETION
Product shall be built in accordance with the specifications hereto attached, delays due to acts of God, strikes, war, or
intentional conflict, failures to obtain chassis, materials, unusual weather conditions or other causes beyond GSFA’s control not
preventing, within approximately 285 to 315 CALENDAR DAYS after receipt of this order and the acceptance thereof at our
Sacramento, California office. Within thirty (30) calendar days after receipt of this order and acceptance thereof, GSFA shall
submit to Customer a production schedule including tentative pre-construction conference, final inspection and final delivery
dates.
DELIVERY LOCATION
Product shall be shipped in accordance with the specifications hereto attached and be delivered to you at SAN RAFAEL,
CALIFORNIA. Proof of insurance must be demonstrated by the Customer to GSFA prior to transferring of the Product(s).
Submitted Date: December 17, 2018
Proposal Number: 81217-18
Expiration Date: January 31, 2019
Sales Consultant: Daron Wright
# Description Unit Price
A One (1) Pierce Manufacturing, Enforcer 1500 GPM Pumper 603,066.65
B Discount For 100% Pre-Payment at Time of Order (21,449.78)
SUBTOTAL 581,616.87
9.00% State Sales Tax 52,345.52
California Tire Fee 10.50
GRAND TOTAL 633,972.89
7400 Reese Road, Sacramento, CA 95828 | Office 916.330.1638 | Fax 916.330.1649 Page 3 of 3
ACCEPTING THIS PROPOSAL
In the event Customer wishes to purchase the Product described in this Proposal and the attached specifications, then, prior to the expiration
date listed on page 2 of this Proposal, Customer shall sign and return this Proposal. Thereafter, GSFA and Customer will endeavor to enter into
a purchase agreement incorporating this Proposal and including additional terms (a “Purchase Agreement”). If Customer returns a signed copy
of this Proposal alone, GSFA will send Customer its form of Purchase Agreement for Customer’s review and signature. If Customer desires to
use its standard form of purchase order as the Purchase Agreement, then Customer should return a signed copy of this Proposal along with a copy
of such purchase order. All purchase orders shall be made out to GSFA. GSFA will review such purchase order and contact the Customer
regarding any required revisions. Only upon a full execution of a Purchase Agreement shall GSFA and Customer be obligated to purchase and
sell the Product set forth in this Proposal.
TERMS AND CONDITIONS
The following Terms and Conditions are hereby made part of this Proposal:
1. Payment Terms, 100% Pre-Payment at Time of Order –
Customer shall pay the amount listed on page one of this
Proposal, which includes: (i) the total price for the Product (the
“Purchase Price”), (ii) the estimated state sales tax on the Product,
and (iii) the California tire fee (together with the Purchase Price
and estimated state sales tax, the “Grand Total”) within fifteen
(15) calendar days from the date on which the Purchase
Agreement is fully executed. The proposed delivery timeframe for
the Product, which is outlined on page one of this Proposal, shall
not begin until full payment of the Grand Total is received. In the
event Customer does not pay GSFA the Grand Total in the
timeframe set forth in this Section 1, GSFA may, in its sole
discretion, cancel the Purchase Agreement entered into between
the parties.
2. Multiple Unit Purchase – If the Purchase Price includes pricing
for multiple units, the price stated on this Proposal shall only be
valid if the quantity of Products being proposed are purchased at
the same time, pursuant to the same Purchase Agreement.
3. Stock / Demo Units – If applicable, any stock/demo units,
including those identified by this Proposal, are available for sale
on an as-is, first-come and first served-basis. Regardless of this
Proposal, the first Customer to enter into a Purchase Agreement
identifying any such stock/demo unites shall obtain said units.
4. Order Changes – The Customer may request that GSFA
incorporate a change to the Product or the Specifications for the
Product by delivering a written change order to GSFA, which shall
include a description of the proposed change sufficient to permit
GSFA to evaluate the feasibility of such change (a “Change
Order”). GSFA will provide Customer a written response (a
“Response”) stating (i) whether GSFA will accommodate such
Change Order (which GSFA may decide in its sole and absolute
discretion) and (ii) the terms of the modification to the order,
including any increase or decrease in the Purchase Price resulting
from such Change Order, and any effect on production scheduling
or Delivery resulting from such Change Order. Customer shall
have seven (7) days after receipt of the Response to notify GSFA
as to whether Customer desires to make the changes GSFA has
approved in the Response. In the event Customer counter-signs
GSFA’s Response, Customer shall pay the increase (or be
refunded the decrease) in the Purchase Price prior to final
delivery to Customer location.
5. Force Majeure – GSFA shall not be responsible nor deemed to
be in default on account of delays in performance due to causes
which are beyond GSFA’s and manufacturer’s control and which
make GSFA’s performance impracticable, including but not limited
to wars, insurrections, strikes, riots, fires, storms, floods, other
acts of nature, explosions, earthquakes, accidents, any act of
government, delays in transportation, inability to obtain
necessary labor supplies or manufacturing facilities, allocation
regulations or orders affecting materials, equipment, facilities or
completed products, failure to obtain any required license or
certificates, acts of God or the public enemy or terrorism, failure
of transportation, epidemics, quarantine restrictions, failure of
vendors (due to causes similar to those within the scope of this
clause) to perform their contracts or labor troubles causing
cessation, slowdown, or interruption of work.
6. Cancellation/Termination – In the event Customer and GSFA
enter into a Purchase Agreement and Customer thereafter
cancels or terminates the Purchase Agreement, GSFA will charge
a cancellation fee as follows: (a) 10% of the Purchase Price after
order is accepted and entered by GSFA; (b) 20% of the Purchase
Price after completion of the pre-construction phase of the order
process; and (c) 50% of the Purchase Price after the requisition of
any materials or commencement of any manufacturing or
assembly of the Product by either GSFA or the manufacturer of
the Product. The tier of cancellation fee applicable to any
cancellation shall be in the sole and absolute discretion of GSFA.
7. State Sales Tax – Customer shall be responsible for the cost of
state sales tax associated with, or attributable to the Product. The
taxes owed by Customer for the Product is subject to adjustment
for the applicable state sales tax rate in effect when the Product is
delivered to the Customer. Therefore, the sales tax will be
increased or decreased at the time of delivery if a change in the
sales tax rate has occurred, in which case Customer shall pay
GSFA (or be refunded by GSFA) the applicable change in sales tax.
8. Proposal Expiration – After the Expiration Date shown on page
one of this Proposal, Customer shall require GSFA’s written
consent to accept this Proposal.
9. Governing Law – This Proposal is to be governed by and under
the laws of the state of California.
Thank you for providing Golden State Fire Apparatus, Inc. with the opportunity to provide this proposal. If you have any questions regarding
the options presented or need additional options, please contact me.
Sincerely, I, _______________________________________________________________authorized representative of
SAN RAFAEL FIRE DEPARTMENT agrees to purchase the proposed Product(s) and agree to
the terms and conditions of this proposal and the specifications hereto attached.
Daron Wright SIGNATURE: _________________________________________________________________________________
Golden State Fire Apparatus, Inc.
TITLE: _________________________________________________ DATE: ______________________________
PROPOSAL NO. 81217-18Proposal Details Report
OptionCode Type Option ProposalText
0766611 Boiler Plates, Pumper
Golden State Fire Apparatus, Inc. is pleased to submit a proposal to San Rafael Fire Department
for a Pierce® triple combination pumper per your request for quotation. The following
paragraphs will describe in detail the apparatus, construction methods, and equipment proposed.
This proposal will indicate size, type, model and make of components parts and equipment,
providing proof of compliance with each and every item (except where noted) in the departments
advertised specifications.
PIERCE MANUFACTURING was founded in 1913. Since then we have been building bodies with
one philosophy, "BUILD THE FINEST". Our skilled craftsmen take pride in their work, which is
reflected, in the final product. We have been building fire apparatus since the early "forties" giving
Pierce Manufacturing over 75 years of experience in the fire apparatus market. Pierce
Manufacturing has built and put into service more than 62,500 apparatus, including more than
33,900 on Pierce custom chassis designed and built specifically for fire and emergency
applications. Our Appleton, Wisconsin facility has over 870,000 total square feet of floor space
situated on approximately 105 acres of land. Our Bradenton, Florida facility has 300,000 square
feet of floor space situated on approximately 38 acres of land.
Our beliefs in high ethical standards are carried through in all of our commitments and to
everyone with whom we do business. Honesty, Integrity, Accountability and Citizenship are global
tenets by which we all live and work. Consequently, we neither engage in, nor have we ever been
convicted of price fixing, bid rigging, or collusion in any domestic or international fire apparatus
market.
Pierce has only one brand of fire apparatus "Pierce", ensuring you are receiving top of the line
product that meets your specification.
In accordance with the current edition of NFPA 1901 standards, this proposal will specify whether
the fire department, manufacturer, or apparatus dealership will provide required loose equipment.
Images and illustrative material in this proposal are as accurate as known at the time of
publication, but are subject to change without notice. Images and illustrative material is for
reference only, and may include optional equipment and accessories and may not include all
standard equipment.
GENERAL DESIGN AND CONSTRUCTION
To control quality, ensure compatibility, and provide a single source for service and warranty, the
custom cab, chassis, pump module and body will be entirely designed, assembled/welded and
painted in Pierce owned manufacturing facilities. This includes, but not limited to the cab
weldment, the pumphouse module assembly, the chassis assembly, the body and the electrical
system.
QUALITY AND WORKMANSHIP
Pierce has set the pace for quality and workmanship in the fire apparatus field. Our tradition of
building the highest quality units with craftsmen second to none has been the rule right from the
beginning and we demonstrate that ongoing commitment by: Ensuring all steel welding follows
American Welding Society D1.1-2004 recommendations for structural steel welding. All aluminum
welding follows American Welding society and ANSI D1.2-2003 requirements for structural
welding of aluminum. All sheet metal welding follows American welding Society B2.1-2000
requirements for structural welding of sheet metal. Our flux core arc welding uses alloy rods, type
7000 and is performed to American Welding Society standards A5.20-E70T1. Furthermore, all
employees classified as welders are tested and certified to meet the American welding Society
codes upon hire and every three (3) years thereafter. Pierce also employs and American Welding
Society certified welding inspector in plant during working hours to monitor weld quality.
Pierce Manufacturing operates a Quality Management System under the requirements of ISO
9001. These standards sponsored by the International Organization for Standardization (ISO)
specify the quality systems that are established by the manufacturer for design, manufacture,
installation and service. A copy of the certificate of compliance is included with this proposal.
In addition to the Quality Management system, we also employ a Quality Achievement Supplier
program to insure the vendors and suppliers that we utilize meet the high standards we demand.
That is just part of our overall "Quality at the Source" program at Pierce.
To demonstrate the quality of our products and services, a list of at least fire
departments/municipalities that have purchased vehicles for a second time is provided.
DELIVERY
The apparatus will be delivered under its own power to insure proper break-in of all components
while the apparatus is still under warranty.
MANUAL AND SERVICE INFORMATION
At time of delivery, complete operation and maintenance manuals covering the apparatus will be
provided. A permanent plate will be mounted in the driver's compartment specifying the quantity
and type of fluids required including engine oil, engine coolant, transmission, pump transmission
lubrication, pump primer and drive axle.
SAFETY VIDEO
At the time of delivery Pierce will also provide one (1) 39-minute, professionally produced
apparatus safety video, in DVD format. This video will address key safety considerations for
personnel to follow when they are driving, operating, and maintaining the apparatus, including the
following: vehicle pre-trip inspection, chassis operation, pump operation, aerial operation, and
safety during maintenance.
PERFORMANCE TESTS
A road test will be conducted with the apparatus fully loaded and a continuous run of no less than
ten (10) miles. During that time the apparatus will show no loss of power nor will it overheat. The
transmission drive shaft or shafts and the axles will run quietly and be free of abnormal vibration
or noise. The apparatus when fully loaded will not have less than 25 percent nor more than 50
12/17/2018
Customer:San Rafael FD Bid Number: 377
Representative Wright, Daron Job Number:
Requirements Manager:Organization:Golden State Fire Apparatus, Inc
Description: 1500 GPM Pumper (Ref. Previo
Chassis:Enforcer Chassis
Body: Pumper, Short, Galvanneal, 2nd Gen
1377Bid #:
PROPOSAL NO. 81217-18percent on the front axle, and not less than 50 percent nor more than 75 percent on the rear axle.
The apparatus will meet NFPA 1901 acceleration and braking requirements.
SERVICE AND WARRANTY SUPPORT
Pierce dealership support will be provided by Golden State Emergency Service, Inc. by operating
a Pierce authorized service center. The service center will have factory-trained mechanics on
staff versed in Pierce fire apparatus. The service facility will be located within of the fire
department.
In addition to the dealership, Pierce has service facilities located in both, Weyauwega, Wisconsin
and Bradenton, Florida. Pierce also maintains a dedicated parts facility of over 100,000 square
feet in Appleton, Wisconsin. The parts facility stocks in excess of $5,000,000 in parts dedicated to
service and replacement parts. The parts facility employs a staff dedicated solely for the
distribution and shipment of service and replacement parts.
Service parts for the apparatus being proposed can be found via Pierceparts.com which, is an
interactive online tool that delivers information regarding your specific apparatus as well as the
opportunity to register for training classes.
As a Pierce customer you have the ability to view the complete bill of materials for your specific
apparatus, including assembly drawings, piece part drawings, and beneficial parts notations. You
will also have the ability to search the complete Pierce item master through a parts search
function which offers all Pierce SKU's and descriptions offered on all Pierce apparatus. Published
component catalogs, which include proprietary systems along with an extensive operators
manual library is available for easy reference.
Pierce Manufacturing maintains a dedicated service and warranty staff of over 35 personnel,
dedicated to customer support, which also maintains a 24 hour 7 day a week toll free hot line,
four (4) on staff EVTs, and offers hands-on repair and maintenance training classes multiple
times a year.
LIABILITY
The successful bidder will defend any and all suits and assume all liability for the
use of any patented process including any device or article forming a part of the
apparatus or any appliance furnished under the contract.
INSURANCE PROVIDED BY BIDDER
COMMERCIAL GENERAL LIABILITY INSURANCE
The successful bidder will, during the performance of the contract and for three (3)
years following acceptance of the product, keep in force at least the following
minimum limits of commercial general liability insurance:
Each Occurrence $1,000,000
Products/Completed Operations Aggregate $1,000,000
Personal and Advertising Injury $1,000,000
General Aggregate $2,000,000
Coverage will be written on a Commercial General Liability form. The policy will be
written on an occurrence form and will include Contractual Liability coverage for
bodily injury and property damage subject to the terms and conditions of the policy.
The policy will include Owner as an additional insured when required by written
contract.
COMMERCIAL AUTOMOBILE LIABILITY INSURANCE
The successful bidder will, during the performance of the contract, keep in force at
least the following minimum limits of commercial automobile liability insurance and
coverage will be written on a Commercial Automobile liability form:
Each Accident Combined Single Limit: $1,000,000
UMBRELLA/EXCESS LIABILITY INSURANCE
The successful bidder will, during the performance of the contract and for three (3)
years following acceptance of the product, keep in force at least the following
minimum limits of umbrella liability insurance:
Aggregate: $3,000,000
Each Occurrence: $3,000,000
The umbrella policy will be written on an occurrence basis and at a minimum provide
excess to the bidder's General Liability and Automobile Liability policies.
The required limits can be provided by one (1) or more policies provided all other
insurance requirements are met.
Coverage will be provided by a carrier(s) rated A- or better by A.M. Best.
All policies will provide a 30-day notice of cancellation to the named insured. The
Certificate of Insurance will provide the following cancellation clause: Should any of
the above described polices be cancelled before the expiration date thereof, notice
will be delivered in accordance with the policy provisions.
Bidder agrees to furnish owner with a current Certificate of Insurance with the
coverages listed above along with the bid. The certificate will show the purchaser as
certificate holder.
INSURANCE PROVIDED BY MANUFACTURER
PRODUCT LIABILITY INSURANCE
The manufacturer will, during the performance of the contract and for three (3) years
following acceptance of the product, keep in force at least the following minimum
limits of Product Liability insurance:
Each Occurrence $1,000,000
Products/Completed Operations Aggregate $1,000,000
Coverage will be written on a Commercial General Liability form. The policy will be
written on an occurrence form. The manufacturer's policy will include the owner as
additional insured when required by written contract between the Owner and a
Pierce authorized dealer.
UMBRELLA/EXCESS LIABILITY INSURANCE
The manufacturer will, during the performance of the contract and for three (3) years
following acceptance of the product, keep in force at least the following minimum
limits of umbrella liability insurance:
Each Occurrence: $25,000,000
Aggregate: $25,000,000
2377Bid #:
PROPOSAL NO. 81217-18The umbrella policy will be written on an occurrence basis and provide excess to the
manufacturer's General Liability/Products policies.
The required limits can be provided by one (1) or more policies provided all other
insurance requirements are met.
Coverage will be provided by a carrier(s) rated A- or better by A.M. Best.
All policies will provide a 30-day notice of cancellation to the named insured. The
Certificate of Insurance will provide the following cancellation clause: Should any of
the above described polices be cancelled before the expiration date thereof, notice
will be delivered in accordance with the policy provisions.
Manufacturer agrees to furnish owner with a current Certificate of Insurance with the
coverages listed above along with the bid. The certificate will show the purchaser as
the certificate holder.
0661794 Single Source Compliance
SINGLE SOURCE MANUFACTURER
Pierce Manufacturing, Inc. provides an integrated approach to the design and manufacture of our
products that delivers superior apparatus and a dedicated support team. From our facilities, the
chassis, cab weldment, cab, pumphouse (including the sheet metal enclosure, valve controls,
piping and operators panel) and body will be entirely designed, tested, and hand assembled to
the customer's exact specifications. The electrical system either hardwired or multiplexed, will be
both designed and integrated by Pierce Manufacturing. The warranties relative to these major
components (excluding component warranties such as engine, transmission, axles, pump, etc.)
will be provided by Pierce as a single source manufacturer. Pierce's single source solution adds
value by providing a fully engineered product that offers durability, reliability, maintainability,
performance, and a high level of quality.
0584456 Manufacture Location, Appleton,
Wisconsin
Your apparatus will be manufactured in Appleton, Wisconsin.
0584452 RFP Location: Appleton, Wisconsin
0588609 Vehicle Destination, US
0520877 Comparison Report Required
COMPARISON REPORT
A report will be provided to allow the Sales Representative to compare the options to a previous
job. The report will be provided for job 30272 (01-02).
0610784 Comply NFPA 1901 Changes
Effective Jan 1, 2016, With
Exceptions
NFPA 2016 STANDARDS
This unit will comply with the NFPA standards effective January 1, 2016, except for fire
department directed exceptions. These exceptions will be set forth in the Statement of
Exceptions.
Certification of slip resistance of all stepping, standing and walking surfaces will be supplied with
delivery of the apparatus.
All horizontal surfaces designated as a standing or walking surface that are greater than 48.00"
above the ground must be defined by a 1.00" wide line along its outside perimeter. Perimeter
markings and designated access paths to destination points will be identified on the customer
approval print and are shown as approximate. Actual location(s) will be determined based on
materials used and actual conditions at final build. Access paths may pass through hose storage
areas and opening or removal of covers or restraints may be required. Access paths may require
the operation of devices and equipment such as the aerial device or ladder rack.
A plate that is highly visible to the driver while seated will be provided. This plate will show the
overall height, length, and gross vehicle weight rating.
The manufacturer will have programs in place for training, proficiency testing and performance for
any staff involved with certifications.
An official of the company will designate, in writing, who is qualified to witness and certify test
results.
0533347 Pumper/Pumper with Aerial Device
Fire Apparatus
0588611 Vehicle Certification, Pumper
3377Bid #:
PROPOSAL NO. 81217-180661778 Agency, Apparatus Certification,
Pumper/Tanker, U.L.
NFPA COMPLIANCY
Apparatus proposed by the bidder will meet the applicable requirements of the National Fire
Protection Association (NFPA) as stated in current edition at time of contract execution. Fire
department's specifications that differ from NFPA specifications will be indicated in the proposal
as "non-NFPA".
VEHICLE INSPECTION PROGRAM CERTIFICATION
To assure the vehicle is built to current NFPA standards, the apparatus, in its entirety, will be
third-party, audit-certified through Underwriters Laboratory (UL) that it is built and complies to all
applicable standards in the current edition of NFPA 1901. The certification will include: all design,
production, operational, and performance testing of not only the apparatus, but those
components that are installed on the apparatus.
A placard will be affixed in the driver's side area stating the third party agency, the date, the
standard and the certificate number of the whole vehicle audit.
PUMP TEST
Underwriters Laboratory (UL) will test, approved, and certify the pump. The test results and the
pump manufacturer's certification of hydrostatic test; the engine manufacturer's certified brake
horsepower curve; and the pump manufacturer's record of pump construction details will be
forwarded to the Fire Department.
GENERATOR TEST
If the unit has a generator, Underwriters Laboratory (UL) will test, approved, and certify the
generator. The test results will be provided to the Fire Department at the time of delivery.
BREATHING AIR TEST
If the unit has breathing air, Pierce Manufacturing will draw an air sample from the air system and
have the sample certified that the air quality meets the requirements of NFPA 1989, Standard on
Breathing Air Quality for Fire and Emergency Services Respiratory Protection.
0000000 STF GSFA, Final Insp, ATW Factory,
Major Airport, 3 Days and 2 nights
FINAL INSPECTION FACTORY TRIP
A final inspection trip to the manufacturing facility will be provided for two (2) Customer
representative(s). The intent of this trip is to ensure that the apparatus is built to specification and
to detect any deficiencies that require correction. The final inspection trip will have a duration of
three (3) days and two (2) nights and be scheduled at times mutually agreed upon between
Golden State Fire Apparatus Ltd (GSFA). and the Customer. Costs for airfare, lodging, meals and
ground transportation while at the manufacturers location will be the responsibility of GSFA. Air
travel will be from one of the following airports: Sacramento, San Francisco or San Jose.
Costs such as Customer ground transportation in California, Customer airport parking, Customer
luggage fees and Customer incidentals while traveling to the factory will be the responsibility of
the Customer. Flight reservations are non-refundable and in the event of a cancellation after
booking, the Customer will be responsible for all costs associated with this cancellation, which
may include not only the original ticket cost but also any change or cancellation fees imposed by
the airline and/ or travel agency. Flight reservations are also non-transferable.
0620362 Consortium, HGAC
0537375 Unit of Measure, US Gallons
0030006 Bid Bond Not Requested
BID BOND NOT REQUESTED
A bid bond will not be included. If requested, the following will apply:
All bidders will provide a bid bond as security for the bid in the form of a 5% bid bond to
accompany their bid. This bid bond will be issued by a Surety Company who is listed on the U.S.
Treasury Departments list of acceptable sureties as published in Department Circular 570. The
bid bond will be issued by an authorized representative of the Surety Company and will be
accompanied by a certified power of attorney dated on or before the date of bid. The bid bond will
include language, which assures that the bidder/principal will give a bond or bonds as may be
specified in the bidding or contract documents, with good and sufficient surety for the faithful
performance of the contract, including the Basic One (1) Year Limited Warranty, and for the
prompt payment of labor and material furnished in the prosecution of the contract.
Notwithstanding any document or assertion to the contrary, any surety bond related to the sale of
a vehicle will apply only to the Basic One (1) Year Limited Warranty for such vehicle. Any surety
bond related to the sale of a vehicle will not apply to any other warranties that are included within
this bid (OEM or otherwise) or to the warranties (if any) of any third party of any part, component,
attachment or accessory that is incorporated into or attached to the vehicle. In the event of any
contradiction or inconsistency between this provision and any other document or assertion, this
provision will prevail.
4377Bid #:
PROPOSAL NO. 81217-180582697 Performance Bond, 100 Percent
w/Warranty Bond, 1 Yr, and Payment
Bond
PERFORMANCE BOND, 1 YEAR
The successful bidder will furnish a Performance and Payment bond (Bond) equal to 100 percent
of the total contract amount within 30 days of the notice of award. Such Bond will be in a form
acceptable to the Owner and issued by a surety company included within the Department of
Treasury's Listing of Approved Sureties (Department Circular 570) with a minimum A.M. Best
Financial Strength Rating of A and Size Category of XV. In the event of a bond issued by a
surety of a lesser Size Category, a minimum Financial Strength rating of A+ is required.
Bidder and Bidder's surety agree that the Bond issued hereunder, whether expressly stated or
not, also includes the surety's guarantee of the vehicle manufacturer's Basic One (1) Year Limited
Warranty period included within this proposal. Owner agrees that the penal amount of this bond
will be simultaneously amended to 100% percent of the total contract amount upon satisfactory
acceptance and delivery of the vehicle(s) included herein. Notwithstanding anything contained
within this contract to the contrary, the surety's liability for any warranties of any type will
not exceed one (1) year from the date of such satisfactory acceptance and delivery, or the actual
Basic One (1) Year Limited Warranty period, whichever is shorter.
0000007 Approval Drawing APPROVAL DRAWING
A drawing of the proposed apparatus will be prepared and provided to the purchaser for approval
before construction begins. The Pierce sales representative will also be provided with a copy of
the same drawing. The finalized and approved drawing will become part of the contract
documents. This drawing will indicate the chassis make and model, location of the lights, siren,
horns, compartments, major components, etc.
A "revised" approval drawing of the apparatus will be prepared and submitted by Pierce to the
purchaser showing any changes made to the approval drawing.
0082910 Drawing, Compartment Layout,
Standard Pumper Body
DRAWING, COMPARTMENT LAYOUT
A basic drawing will be provided for the interior body compartments. This drawing will be provided
for graphic representation only and will include such things as shelves, trays, reels, dividers, air
control panels, air bottle storage bins, poly boxes & etc.
0672031 Drawing, Cab, Top View, Seating and
EMS Cabinets, Reference Only
DRAWING, CAB TOP VIEW
On the sales drawing a top view of the cab seating and EMS cabinets will be provided. The top
view will be a reference only of the seating and EMS cabinets in the order.
0002928 Electrical Diagrams
ELECTRICAL WIRING DIAGRAMS
Two (2) electrical wiring diagrams, prepared for the model of chassis and body, will be provided.
0649754 Enforcer Chassis
ENFORCER CHASSIS
The Pierce Enforcer™ is the custom chassis developed exclusively for the fire service. Chassis
provided will be a new, tilt-type custom fire apparatus. The chassis will be manufactured in the
apparatus body builder's facility eliminating any split responsibility. The chassis will be designed
and manufactured for heavy-duty service, with adequate strength, capacity for the intended load
to be sustained, and the type of service required. The chassis will be the manufacturer's first line
tilt cab.
0523786 Angle of Approach ANGLE OF APPROACH
The angle of approach will be as much as possible (please show exact on AD) degrees. This will
be effective with the truck in a loaded state.
0523787 Angle of Departure ANGLE OF DEPARTURE
The angle of departure will be as much as possible (please show exact on AD) degrees. This will
be effective with the truck in a loaded state.
0000110 Wheelbase WHEELBASE
The wheelbase of the vehicle will be 174.50".
0000070 GVW Rating GVW RATING
The gross vehicle weight rating will be 42,000#.
0649713 Frame Rails, 10.25" x 3.50" x .375",
Saber FR/Enf
FRAME
The chassis frame will be built with two (2) steel channels bolted to five (5) cross members or
more, depending on other options of the apparatus. The side rails will be heat-treated steel
measuring 10.25" x 3.50" x .375".
Each rail will have a section modulus of 16.00 cubic inches, yield strength of 120,000 psi, and a
resisting bending moment (rbm) of 1,921,069 inch-pounds.
5377Bid #:
PROPOSAL NO. 81217-180648354 Frame Liner, Internal "C", 9.38" x
3.13" x .25", Saber FR/Enf, 26" Qval
FRAME REINFORCEMENT
A full-length mainframe "C" liner will be provided.
The liner will be an internal "C" design, heat-treated steel measuring 9.38" x 3.13" x 0.25". Each
reinforcement member will have a section modulus of 3.90 cubic inches, yield strength of 120,000
psi and resisting bending moment (rbm) of 938,762 in-lb.
0633906 Axle, Front, Oshkosh TAK-4, Non
Drive, 18,000 lb, Enforcer
FRONT NON DRIVE AXLE
The Oshkosh TAK-4® front axle will be of the independent suspension design with a ground
rating of 18,000 lb.
Upper and lower control arms will be used on each side of the axle. Upper control arm castings
will be made of 100,000-psi yield strength 8630 steel and the lower control arm casting will be
made of 55,000-psi yield ductile iron.
The center cross members and side plates will be constructed out of 80,000-psi yield strength
steel.
Each control arm will be mounted to the center section using elastomer bushings. These rubber
bushings will rotate on low friction plain bearings and be lubricated for life. Each bushing will also
have a flange end to absorb longitudinal impact loads, reducing noise and vibrations.
There will be nine (9) grease fittings supplied, one (1) on each control arm pivot and one (1) on
the steering gear extension.
The upper control arm will be shorter than the lower arm so that wheel end geometry provides
positive camber when deflected below rated load and negative camber above rated load.
Camber at load will be zero degrees for optimum tire life.
The ball joint bearing will be of low friction design and be maintenance free.
Toe links that are adjustable for alignment of the wheel to the center of the chassis will be
provided.
The wheel ends must have little to no bump steer when the chassis encounters a hole or
obstacle.
The steering linkage will provide proper steering angles for the inside and outside wheel, based
on the vehicle wheelbase.
The axle will have a third party certified turning angle of 45 degrees. Front discharge, front
suction, or aluminum wheels will not infringe on this cramp angle.
0612512 SP Suspension, Front TAK-4, 18,000 lb,
5" Jounce, Enforcer
FRONT SUSPENSION
Front Oshkosh TAK-4™ independent suspension will be provided with a minimum ground rating
of 18,000 lb.
The independent suspension system will be designed to provide maximum ride comfort. The
design will allow the vehicle to travel at highway speeds over improved road surfaces and
moderate speeds over rough terrain with minimal transfer of road shock and vibration to the
vehicle's crew compartment.
Each wheel will have a torsion bar type spring. In addition, each front wheel end will have energy
absorbing jounce bumpers to prevent bottoming of the suspension.
The suspension design will have at least 10.00" of total wheel travel and a minimum of 5.00"
before suspension bottoms.
The torsion bar anchor lock system allows for simple lean adjustments without the use of shims.
One can adjust for a lean within fifteen minutes per side. Anchor adjustment design is such that it
allows for ride height adjustment on each side.
The independent suspension completed durability testing that simulated 140,000 miles of inner
city driving.
0087572 Shock Absorbers, KONI, TAK-4,
Qtm/AXT/Imp/Vel/DCF/Enf
FRONT SHOCK ABSORBERS
KONI heavy-duty telescoping shock absorbers will be provided on the front suspension.
6377Bid #:
PROPOSAL NO. 81217-180000322 Oil Seals, Front Axle FRONT OIL SEALS
Oil seals with viewing window will be provided on the front axle.
0582936 Tires, Front, Goodyear, G289 WHA,
315/80R22.50, 20 ply
FRONT TIRES
Front tires will be Goodyear® 315/80R22.50 radials, 20 ply G289 WHA tread, rated for 20,400 lb
maximum axle load and 68 mph maximum speed.
0019575 Wheels, Front, Alcoa, 22.50" x 9.00",
Aluminum, Hub Pilot
The tires will be mounted on Alcoa 22.50" x 9.00" polished aluminum disc wheels with a ten (10)
stud, 11.25" bolt circle.
0530457 Axle, Rear, Meritor RS23-186, 24,000
lb Saber/Enforcer
REAR AXLE
The rear axle will be a Meritor™, Model RS-23-186, with a capacity of 24,000 lb.
0544253 Top Speed of Vehicle, 68 MPH
TOP SPEED OF VEHICLE
A rear axle ratio will be furnished to allow the vehicle to reach a top speed of 68 mph.
0565379 Suspen, Rear, Single Slipper Spring,
24,000 lb, Saber/Enforcer
REAR SUSPENSION
The rear suspension will be Standens, semi-elliptical, 3.00" wide x 53.00" long, 12-leaf pack with
a ground rating of 24,000 lb. The spring hangers will be castings.
The two (2) top leaves will wrap the forward spring hanger pin, and the rear of the spring will be a
slipper style end that will ride in a rear slipper hanger. To reduce bending stress due to
acceleration and braking, the front eye will be a berlin eye that will place the front spring pin in the
horizontal plane within the main leaf.
A steel encased rubber bushing will be used in the spring eye. The steel encased rubber bushing
will be maintenance free and require no lubrication.
0000485 Oil Seals, Rear Axle
REAR OIL SEALS
Oil seals will be provided on the rear axle(s).
0587216 Tires, Rear, Goodyear, G622 RSD,
12R22.50, 16 ply, Single
REAR TIRES
Rear tires will be four (4) Goodyear® 12R22.50 radials, 16 ply all season G622 RSD tread, rated
for 27,120 lb maximum axle load and 75 mph maximum speed.
0019625 Wheels, Rear, Alcoa, 22.50" x 8.25",
Aluminum, Hub Pilot, Single
The tires will be mounted on Alcoa 22.50" x 8.25" polished aluminum disc wheels with a ten (10)
stud 11.25" bolt circle.
0568081 Tire Balancing, Counteract Beads
TIRE BALANCE
All tires will be balanced with Counteract balancing beads. The beads will be inserted into the tire
and eliminate the need for wheel weights.
0620570 Tire Pressure Monitoring,
RealWheels, AirSecure, Valve Cap,
Single Axle
TIRE PRESSURE MANAGEMENT
There will be a RealWheels LED AirSecure™ tire alert pressure management system provided,
that will monitor each tire's pressure. A sensor will be provided on the valve stem of each tire for
a total of six (6) tires.
The sensor will calibrate to the tire pressure when installed on the valve stem for pressures
between 10 and 200 psi. The sensor will activate an integral battery operated LED when the
pressure of that tire drops 5 to 8 psi.
Removing the cap from the sensor will indicate the functionality of the sensor and battery. If the
sensor and battery are in working condition, the LED will immediately start to flash.
0057936 Covers, Lug Nut, Chrome
CHROME LUG NUT COVERS
Chrome lug nut covers will be supplied on front and rear wheels.
0002045 Mud Flaps, w/logo front & rear
MUD FLAPS
Mud flaps with a Pierce logo will be installed behind the front and rear wheels.
0544802 Chocks, Wheel, SAC-44-E, Folding
WHEEL CHOCKS
There will be one (1) pair of folding Ziamatic, Model SAC-44-E, aluminum alloy, Quick-Choc
wheel blocks, with easy-grip handle provided.
7377Bid #:
PROPOSAL NO. 81217-180544806 Mounting Brackets, Chocks, SAC-44-
E, Folding, Horizontal
WHEEL CHOCK BRACKETS
There will be one (1) pair of Zico, Model SQCH-44-H, horizontal mounting wheel chock brackets
provided for the Ziamatic, Model SAC-44-E, folding wheel chocks. The brackets will be made of
aluminum and consist of a quick release spring loaded rod to hold the wheel chocks in place. The
brackets will be mounted one (1) forward and one (1) rearward of the left side rear tire.
0010670 ABS Wabco Brake System, Single
rear axle
ANTI-LOCK BRAKE SYSTEM
The vehicle will be equipped with a Meritor WABCO 4S4M, anti-lock braking system. The ABS
will provide a 4-channel anti-lock braking control on both the front and rear wheels. A digitally
controlled system that utilizes microprocessor technology will control the anti-lock braking system.
Each wheel will be monitored by the system. When any particular wheel begins to lockup, a
signal will be sent to the control unit. This control unit then will reduce the braking of that wheel
for a fraction of a second and then reapply the brake. This anti-lock brake system will eliminate
the lockup of any wheel thus helping to prevent the apparatus from skidding out of control.
0030185 Brakes, Knorr/Bendix 17", Disc,
Front, TAK-4
BRAKES
The service brake system will be full air type.
The front brakes will be Knorr/Bendix disc type with a 17.00" ventilated rotor for improved
stopping distance.
The brake system will be certified, third party inspected, for improved stopping distance.
0000730 Brakes, Meritor, Cam, Rear, 16.50 x
7.00"
The rear brakes will be Meritor™ 16.50" x 7.00" cam operated with automatic slack adjusters.
Dust shields will be provided.
0020784 Air Compressor, Brake,
Cummins/Wabco 18.7 CFM
BRAKE SYSTEM AIR COMPRESSOR
The air compressor will be a Cummins/WABCO with 18.7 cubic feet per minute output.
0644232 Brake Reservoirs, 4,272 Cubic Inch
Minimum Capacity, Saber
FR/Enforcer
BRAKE SYSTEM
The brake system will include:
Brake treadle valve
Heated automatic moisture ejector on air dryer
Total air system minimum capacity of 4,272 cubic inches
Two (2) air pressure gauges with a red warning light and an audible alarm, that activates when air
pressure falls below 60 psi
Spring set parking brake system
Parking brake operated by a push-pull style control valve
A parking "brake on" indicator light on instrument panel
Park brake relay/inversion and anti-compounding valve, in conjunction with a double check valve
system, with an automatic spring brake application at 40 psi
A pressure protection valve to prevent all air operated accessories from drawing air from the air
system when the system pressure drops below 80 psi (550 kPa)
1/4 turn drain valves on each air tank
The air tank will be primed and painted to meet a minimum 750 hour salt spray test.
To reduce the effects of corrosion, the air tank will be mounted with stainless steel brackets.
0644228 Air Dryer, Wabco System Saver 1200
IWT, Heated, Saber FR/Enforcer
BRAKE SYSTEM AIR DRYER
The air dryer will be a WABCO System Saver 1200 IWT, with internal wet tank, spin-on
coalescing filter cartridge and 100 watt heater.
0000790 Brake Lines, Nylon BRAKE LINES
Color-coded nylon brake lines will be provided. The lines will be wrapped in a heat protective
loom in the chassis areas that are subject to excessive heat.
0544415 Inlet/Outlet, Air, w/Disconnect Fitting,
Location
AIR INLET/OUTLET
One (1) air inlet/outlet will be installed with the female coupling located DS step well (match
previous customer unit, job #28388) Picture in job E folder.. This system will tie into the "wet" tank
of the brake system and include a check valve in the inlet line and an 85 psi pressure protection
valve in the outlet line. The air outlet will be controlled by a needle valve.
A mating male fitting will be provided with the loose equipment.
The air inlet will allow a shoreline air hose to be connected to the vehicle. This will allow station
air to be supplied to the brake system of the vehicle to insure constant air pressure.
0000860 Outlet, Air, with shut off valve
AIR OUTLET
One (1) air outlet will be installed with a female coupling and shut off valve, located on the
passenger side pump panel. This system will tie into the "wet" tank of the brake system and
include an 85-psi pressure protection valve in the outlet line to prevent the brake system from
losing all air.
Female coupling and male fitting will be .25" thread.
A mating male fitting will be provided with the loose equipment.
8377Bid #:
PROPOSAL NO. 81217-180000810 All Wheel Lock-up
ALL WHEEL LOCK-UP
An all wheel lock-up system will be installed which will apply air to the front brakes and use the
spring brake at the rear. A control switch will be provided for the driver on the instrument panel.
The all wheel lock-up system will be operational only when the parking brake is applied, the truck
transmission is in neutral and engine is running.
0795472 Engine, Cummins L9, 450 hp, 1250
lb-ft, W/OBD, EPA 2017, Saber
FR/Enforcer
ENGINE
The chassis will be powered by an electronically controlled engine as described below:
Make:
Cummins
Model:
L9
Power:
450 hp at 2100 rpm
Torque:
1250 lb-ft at 1400 rpm
Governed Speed:
2200 rpm
Emissions Level:
EPA 2017
Fuel:
Diesel
Cylinders:
Six (6)
Displacement:
543 cubic inches (8.9L)
Starter:
Delco 39MT™
Fuel Filters:
Spin-on style primary filter with water separator and water-in-fuel sensor. Secondary spin-on style
filter.
The engine will include On-board diagnostics (OBD), which provides self diagnostic and
reporting. The system will give the owner or repair technician access to state of health
information for various vehicle sub systems. The system will monitor vehicle systems, engine and
after treatment. The system will illuminate a malfunction indicator light on the dash console if a
problem is detected.
0001244 High Idle w/Electronic Engine,
Custom
HIGH IDLE
A high idle switch will be provided, inside the cab, on the instrument panel, that will automatically
maintain a preset engine rpm. A switch will be installed, at the cab instrument panel, for
activation/deactivation.
The high idle will be operational only when the parking brake is on and the truck transmission is
in neutral. A green indicator light will be provided, adjacent to the switch. The light will illuminate
when the above conditions are met. The light will be labeled "OK to Engage High Idle."
0678027 Engine Brake, Jacobs Compression
Brake, Cummins Engine, with Allison
Retarder
ENGINE BRAKE
A Jacobs engine brake is to be installed with the controls located on the instrument panel within
easy reach of the driver.
The driver will be able to turn the engine brake system on/off and have high, medium and low
setting.
The high setting of the brake application will activate and work simultaneously with the variable
geometry turbo (VGT) provided on the engine.
The engine brake will be installed in such a manner that when the engine brake is slowing the
vehicle the brake lights are activated.
The ABS system will automatically disengage the auxiliary braking device, when required.
0644227 Clutch, Fan, Air Actuated, Saber
FR/Enforcer
CLUTCH FAN
A fan clutch will be provided. The fan clutch will be automatic when the pump transmission is in
"Road" position, and constantly engaged when in "Pump" position.
0644573 Air Intake, Water & Ember Screen,
Saber FR/Enforcer
ENGINE AIR INTAKE
The engine air intake will be located above the engine cooling package. It will draw fresh air from
the front of the apparatus through the radiator grille.
The ember separator is designed to prevent road dirt and recirculating hot air from entering the
engine.
The ember separator will be easily accessible by tilting the cab.
0794761 Exhaust System, 4", 2017 L9 Engine,
Horizontal, Right Side
EXHAUST SYSTEM
The exhaust system will be stainless steel from the turbo to the engine's aftertreatment device,
and will be 4.00" in diameter. The exhaust system will include a single module aftertreatment
device to meet current EPA standards. An insulation wrap will be provided on all exhaust pipes
between the turbo and aftertreatment device to minimize the heat loss to the aftertreatment
device . The exhaust will terminate horizontally ahead of the right side rear wheels. A tailpipe
diffuser will be provided to reduce the temperature of the exhaust as it exits. Heat deflector
shields will be provided to isolate chassis and body components from the heat of the tailpipe
diffuser.
9377Bid #:
PROPOSAL NO. 81217-180636399 Diffuser, Exhaust, Modified For
Extraction, 4"x6"x4", Flush With Rub
Rail,Chrome
EXHAUST MODIFICATION
The exhaust pipe will be 90 degrees to the body.
The diffuser will be reduced to 4.00" in the center to accommodate the fire department's air
recovery system. The 4.00" extension pipe coming out of the end of the diffuser will be flush with
the body rub rail. There will be a minimum of 4.00" clearance between the top of the 4.00"
extension and the bottom of the body.
There will be a minimum of 2.50" from the exhaust pipe to the under side of the body heat shield.
The last 7.00" of the exhaust will be free of hangers and/or clamps.
The diffuser and extension pipe will be chrome.
0788765 Radiator, Saber FR/Enforcer
RADIATOR
The radiator and the complete cooling system will meet or exceed NFPA and engine
manufacturer cooling system standards.
For maximum corrosion resistance and cooling performance, the entire radiator core will be
constructed using long life aluminum alloy. The radiator core will consist of aluminum fins, having
a serpentine design, brazed to aluminum tubes.
The radiator core will have a minimum front area of 1060 square inches.
Supply tank will be made of heavy duty glass-reinforced nylon and the return tank will be mode of
aluminum. Both tanks will be crimped onto the core assembly using header tabs and a
compression gasket to complete the radiator core assembly. There will be a full steel frame
around the inserts to enhance cooling system durability and reliability.
The radiator will be compatible with commercial antifreeze solutions.
The radiator assembly will be isolated from the chassis frame rails with rubber isolators to prevent
the development of leaks caused by twisting or straining when the apparatus operates over
uneven terrain.
The radiator will include a de-aeration/expansion tank. For visual coolant level inspection, the
radiator will have a built-in sight glass. The radiator will be equipped with a 15 psi pressure relief
cap.
A drain port will be located at the lowest point of the cooling system and/or the bottom of the
radiator to permit complete flushing of the coolant from the system.
Shields or baffles will be provided to prevent recirculation of hot air to the inlet side of the radiator.
0001090 Cooling Hoses, Rubber
COOLANT LINES
Gates, or Goodyear, rubber hose will be used for all engine coolant lines installed by Pierce
Manufacturing.
Hose clamps will be stainless steel constant torque type to prevent coolant leakage. They will
expand and contract according to coolant system temperature thereby keeping a constant
clamping pressure on the hose.
0011126 Fuel Tank, 65 Gallon, Right Side Fill
FUEL TANK
A 65 gallon fuel tank will be provided and mounted at the rear of the chassis. The tank will be
constructed of 12 gauge, hot rolled steel. It is equipped with swash partitions and a vent. To
eliminate the effects of corrosion, the fuel tank will be mounted with stainless steel straps.
A .75" drain plug will be provided in a low point of the tank for draining.
A fill inlet will be located on the right hand side of the body and be covered with a hinged, spring
loaded, stainless steel door that is marked "Ultra Low Sulfur - Diesel Fuel Only."
A .50" diameter vent will be installed from tank top to just below fuel fill inlet.
The fuel tank will meet all FHWA 393.67 requirements, including a fill capacity of 95 percent of
tank volume.
0001129 Lines, Fuel All fuel lines will be provided as recommended by the engine manufacturer.
0618791 DEF Tank, 4.5 Gallon, DS Fill,
Forward of Axle, Common Air Bottle
Door
DIESEL EXHAUST FLUID TANK
A 4.5 gallon diesel exhaust fluid (DEF) tank will be provided and mounted in the driver's side
body forward of the rear axle.
A 0.50" drain plug will be provided in a low point of the tank for drainage.
A fill inlet will be provided and marked "Diesel Exhaust Fluid Only". The fill inlet will be located
below the air bottle storage behind a common door on the driver side of the vehicle.
The tank will meet the engine manufacturers requirement for 10 percent expansion space in the
event of tank freezing.
The tank will include an integrated heater unit that utilizes engine coolant to thaw the DEF in the
event of freezing.
0552777 Fuel Pump for Repriming AUXILIARY FUEL PUMP
An auxiliary electric fuel pump will be added to the fuel line for priming the engine. A switch
located on the cab instrument panel will be provided to operate the pump.
0552567 Shutoff Valve, Fuel Line @ Fuel Tank
FUEL SHUTOFF
A shutoff valve will be installed in the fuel line, at the fuel tank.
0699437 Cooler, Chassis Fuel, Not Req'd.
10377Bid #:
PROPOSAL NO. 81217-180642577 Trans, Allison 5th Gen, 3000 EVS
PR, w/Prognostics, Imp/Vel/Dash
CF/SFR/Enf
TRANSMISSION
An Allison 5th generation, model EVS 3000PR, electronic torque converting automatic
transmission with retarder will be provided.
The transmission will be equipped with prognostics to monitor oil life, filter life, and transmission
health. A wrench icon on the shift selector's digital display will indicate when service is due.
Two (2) PTO openings will be located on both sides of converter housing (positions 4 o'clock and
8 o'clock) as viewed from the rear.
A transmission temperature gauge with red light and audible alarm will be installed on the cab
instrument panel.
The transmission retarder control will be activated 33 percent by release of the accelerator pedal
or 66 percent by slight application of the brake pedal, or 100 percent by heavy application of
brake pedal. A second on/off switch is provided to activate and deactivate the auto apply portion.
The transmission will have the 1300 ft. lb. torque (medium) spring setting for retardation force.
The transmission retarder will have a master "on/off" switch on the instrument panel. Also, a red
indicator light will be provided to warn that transmission is being overworked.
The retarder will be wired to the brake lights so they are energized when the retarder is slowing
the vehicle down.
The ABS system will automatically disengage the auxiliary braking device when required.
0625329 Transmission, Shifter, 5-Spd, Push
Button, 3000 EVS
TRANSMISSION SHIFTER
A five (5)-speed push button shift module will be mounted to right of driver on console. Shift
position indicator will be indirectly lit for after dark operation.
The transmission ratio will be:
1st
3.49 to 1.00
2nd
1.86 to 1.00
3rd
1.41 to 1.00
4th
1.00 to 1.00
5th
0.75 to 1.00
R
5.03 to 1.00
0797408 Transmission Oil Cooler, Modine,
External, w/Modine External Sump
TRANSMISSION COOLER
An externally mounted Modine bar plate transmission oil cooler will be provided using engine
coolant to control the transmission oil temperature. The internal bar plates will be constructed of
stainless steel. The cooler's housing will be constructed of 1020 steel, coated to protect from
corrosion. The cooler will be tagged with information including OEM part number, vendor serial
number and date / lot code.
An externally mounted Modine bar plate transmission oil cooler will be provided using engine
coolant to control the transmission retarder oil temperature. The internal bar plates will be
constructed of stainless steel. The cooler's housing will be constructed of 1020 steel, coated to
protect from corrosion. The cooler will be tagged with information including OEM part number,
vendor serial number and date / lot code.
0090176 Mode, Downshift, Aggressive
downshift to 3rd, w/engine brake, 5
speed
DOWNSHIFT MODE (w/engine brake)
The transmission will be provided with an aggressive downshift mode.
This will provide earlier transmission downshifts to 3rd gear, resulting in improved engine braking
performance.
0604900 SP Program, Transmission, Not To Shift
To Neutral, With Parking Brake
TRANSMISSION PROGRAM
The transmission will not shift to neutral when parking brake is set.
0027843 Fluid, 3000 Series Trans, Allison
Approved TES-295 Synthetic, IPOS,
Custom
TRANSMISSION FLUID
The transmission will be provided with TranSynd, or other Allison approved TES-295 heavy duty
synthetic transmission fluid.
0001370 Driveline, Spicer 1710 DRIVELINE
Drivelines will be a heavy-duty metal tube and be equipped with Spicer® 1710 universal joints.
The shafts will be dynamically balanced before installation.
A splined slip joint will be provided in each driveshaft where the driveline design requires it. The
slip joint will be coated with Glidecoat® or equivalent.
0669988 Steering, Sheppard M110 w/Tilt,
TAK-4, Eaton Pump, w/Cooler
STEERING
Dual Sheppard, Model M110, steering gears, with integral heavy-duty power steering, will be
provided. For reduced system temperatures, the power steering will incorporate an air to oil
cooler and an Eaton, Model VN20, hydraulic pump with integral pressure and flow control. All
power steering lines will have wire braded lines with crimped fittings.
A tilt and telescopic steering column will be provided to improve fit for a broader range of driver
configurations.
11377Bid #:
PROPOSAL NO. 81217-180605356 Steering Wheel, 4 Spoke without
Controls, Saber FR/Enforcer
STEERING WHEEL
The steering wheel will be 18.00" in diameter, have tilting and telescoping capabilities, and a 4-
spoke design.
0559647 Pierce Logo on Horn Button
0606186 Bumper, Non-Extended, Saber
FR/Enforcer
BUMPER
A one (1) piece, ten (10) gauge 304-2B polished stainless steel bumper, minimum of 10.00" high,
will be attached to the front of the chassis frame.
A 9.00" formed steel channel will be mounted directly behind bumper for additional strength.
GRAVEL PAN
A gravel pan, constructed of bright aluminum treadplate, will be furnished between the bumper
and cab face.
0614646 No Lift & Tow Package, Imp/Vel,
AXT, SFR/Enf
0061058 Tow Eyes, Below Deck, S/S
TOW EYES
Two (2) .75" thick stainless steel tow eyes will be installed under the bumper and attached to the
front frame members. The tow eyes will be designed and positioned to allow up to a 6,000 lb
straight horizontal pull in line with the centerline of the vehicle. The tow eyes will not be used for
lifting of the apparatus.
The tow eyes will not be painted.
12377Bid #:
PROPOSAL NO. 81217-180625652 Cab, Enforcer, 6000
CAB
The Enforcer cab will be designed specifically for the fire service and manufactured by the
chassis builder.
The cab will be built by the apparatus manufacturer in a facility located on the manufacturer's
premises.
For reasons of structural integrity and enhanced occupant protection, the cab will be a heavy duty
design, constructed to the following minimal standards.
The cab will have 12 main vertical structural members located in the A-pillar (front cab corner
posts), B-pillar (side center posts), C-pillar (rear corner posts), and rear wall areas. The A-pillar
will be constructed of solid A356-T5 aluminum castings. The B-pillar and C-pillar will be
constructed from 0.13" wall extrusions. The rear wall will be constructed of two (2) 2.00" x 2.00"
outer aluminum extrusions and two (2) 2.00" x 1.00" inner aluminum extrusions. All main vertical
structural members will run from the floor to 4.625" x 3.864" x 0.090" thick roof extrusions to
provide a cage-like structure with the A-pillar and roof extrusions being welded into a 0.25" thick
corner casting at each of the front corners of the roof assembly.
The front of the cab will be constructed of a 0.13" firewall plate, covered with a 0.090" front skin
(for a total thickness of 0.22"), and reinforced with a full width x 0.50" thick cross-cab support
located just below the windshield and fully welded to the engine tunnel. The cross-cab support
will run the full width of the cab and weld to each A-pillar, the 0.13" firewall plate, and the front
skin.
The cab floors will be constructed of 0.125" thick aluminum plate and reinforced at the firewall
with an additional 0.25" thick cross-floor support providing a total thickness of 0.375" of structural
material at the front floor area. The front floor area will also be supported with two (2) triangular
0.30" wall extrusions that also provides the mounting point for the cab lift. This tubing will run from
the floor wireway of the cab to the engine tunnel side plates, creating the structure to support the
forces created when lifting the cab.
The cab will be 96.00" wide (outside door skin to outside door skin) to maintain maximum
maneuverability.
The cab will have an overall height (from the cab roof to the ground) of approximately 99.00". The
overall height listed will be calculated based on a truck configuration with the lowest suspension
weight rating, the smallest diameter tires for the suspension, no water weight, no loose
equipment weight, and no personnel weight. Larger tires, wheels, and suspension will increase
the overall height listed.
The floor to ceiling height inside the crew cab will be 54.50" in the center and outboard positions.
The crew cab floor will measure 36.00" from the rear wall to the front of the rear facing seat risers.
The medium block engine tunnel, at the rearward highest point (knee level), will measure 51.50"
to the rear wall. The big block engine tunnel will measure 41.50" to the rear wall.
The crew cab will be a totally enclosed design with the interior area completely open to improve
visibility and verbal communication between the occupants.
The cab will be a full tilt cab style.
A 3-point cab mount system with rubber isolators will improve ride quality by isolating chassis
vibrations from the cab.
CAB ROOF DRIP RAIL
For enhanced protection from inclement weather, a drip rail will be furnished on the sides of the
cab. The drip rail will be painted to match the cab roof, and bonded to the sides of the cab. The
drip rail will extend the full length of the cab roof.
INTERIOR CAB INSULATION
The cab will include 1.00" insulation in the ceiling, 1.50" insulation in the side walls, and 2.00"
insulation in the rear wall to maximize acoustic absorption and thermal insulation.
FENDER LINERS
Full circular inner fender liners in the wheel wells will be provided.
PANORAMIC WINDSHIELD
A one (1)-piece safety glass windshield will be provided with over 2,775 square inches of clear
viewing area. The windshield will be full width and will provide the occupants with a panoramic
view. The windshield will consist of three (3) layers: outer light, middle safety laminate, and inner
light. The outer light layer will provide superior chip resistance. The middle safety laminate layer
will prevent the windshield glass pieces from detaching in the event of breakage. The inner light
will provide yet another chip resistant layer. The cab windshield will be bonded to the aluminum
windshield frame using a urethane adhesive. A custom frit pattern will be applied on the outside
perimeter of the windshield for a finished automotive appearance.
WINDSHIELD WIPERS
Three (3) electric windshield wipers with washer will be provided that meet FMVSS and SAE
requirements.
The washer reservoir will be able to be filled without raising the cab.
Washer Reservoir Location
13377Bid #:
PROPOSAL NO. 81217-180647919 Engine Tunnel, ISL, Saber
FR/Enforcer
ENGINE TUNNEL
Engine hood side walls will be constructed of 0.375" aluminum. The top will be constructed of
0.125" aluminum and will be tapered at the top to allow for more driver and passenger elbow
room.
The engine hood will be insulated for protection from heat and sound. The noise insulation keeps
the dBA level within the limits stated in the current NFPA 1901 standards.
The engine tunnel will be no higher than 17.00" off the crew cab floor.
0633594 Rear Wall, Interior, Adjustable
Seating
INTERIOR CREW CAB REAR WALL ADJUSTABLE SEATING (PATENT PENDING)
The interior rear wall of the crew cab will have mounting holes every 2.75" to allow for
adjustability of the forward facing crew cab seating along the rear wall. Seats will be adjustable
with use of simple hand tools allowing departments flexibility of their seating arrangement should
their department needs change.
0632103 Rear Wall, Exterior, Cab, Saber
FR/Enforcer
CAB REAR WALL EXTERIOR COVERING
The exterior surface of the rear wall of the cab will be overlaid with bright aluminum treadplate
that covers the entire rear wall .
0639727 Cab Lift, Elec/Hyd, Manual Override,
Saber FR/Enforcer
CAB LIFT
A hydraulic cab lift system will be provided consisting of an electric powered hydraulic pump, dual
lift cylinders, and necessary hoses and valves.
Hydraulic pump will have a manual override for backup in the event of electrical failure.
Lift controls will be located on the right side pump panel or front area of the body in a convenient
location.
The cab will be capable of tilting 43 degrees to accommodate engine maintenance and removal.
The cab will be locked down by a 2-point normally closed spring loaded hook type latch that fully
engages after the cab has been lowered. The system will be hydraulically actuated to release the
normally closed locks when the cab lift control is in the raised position and cab lift system is under
pressure. When the cab is completely lowered and system pressure has been relieved, the spring
loaded latch mechanisms will return to the normally closed and locked position.
The hydraulic cylinders will be equipped with a velocity fuse that protects the cab from
accidentally descending when the control is located in the tilt position.
For increased safety, a redundant mechanical stay arm will be provided that must be manually
put in place on the left side between the chassis and cab frame when the cab is in the raised
position. This device will be manually stowed to its original position before the cab can be
lowered.
Cab Lift Interlock
The cab lift system will be interlocked to the parking brake. The cab tilt mechanism will be active
only when the parking brake is set and the ignition switch is in the on position. If the parking
brake is released, the cab tilt mechanism will be disabled.
14377Bid #:
PROPOSAL NO. 81217-180695930 Grille, Bright Finished, Front of Cab,
Dash CF/Enforcer
GRILLE
A bright finished aluminum mesh grille screen, inserted behind a bright finished grille surround,
will be provided on the front center of the cab.
0002224 Scuffplates, S/S At Cab Door Jambs,
4-Door Cab
DOOR JAMB SCUFFPLATES
All cab door jambs will be furnished with a polished stainless steel scuffplate, mounted on the
striker side of the jamb.
0647932 Not Required, Trim, S/S Band,
Across Cab Face, AXT/Dash
CF/Saber/Enforcer
0087357 Molding, Chrome on Side of Cab
SIDE OF CAB MOLDING
Chrome molding will be provided on both sides of cab.
0569263 Mirrors, Retrac, West Coast Style,
Remote, w/Remote Convex
MIRRORS
A Retrac Aerodynamic, Model 613295, dual vision, motorized, west coast style mirror with
chrome finish will be mounted on each side of the front cab door with spring loaded retractable
arms. The flat glass and convex glass will be adjustable with a remote control within reach of the
driver.
0648171 Door, Half-Height, Saber FR/Enforcer
4-Door Cab, Level Roof
DOORS
To enhance entry and egress to the cab, the forward cab door openings will be a minimum of
37.50" wide x 63.37" high. The crew cab doors will be located on the sides of the cab and will be
constructed in the same manner as the forward cab doors. The crew cab door openings will be a
minimum of 34.30" wide x 63.37" high.
The forward cab and crew cab doors will be constructed of extruded aluminum with a nominal
material thickness of 0.093". The exterior door skins will be constructed from 0.090" aluminum.
A customized, vertical, pull-down type door handle will be provided on the exterior of each cab
door. The exterior handle will be designed specifically for the fire service to prevent accidental
activation, and will provide 4.00" wide x 2.00" deep hand clearance for ease of use with heavy
gloved hands.
Each door will also be provided with an interior flush, open style paddle handle that will be readily
operable from fore and aft positions, and be designed to prevent accidental activation. The
interior handles will provide 4.00" wide x 1.25" deep hand clearance for ease of use with heavy
gloved hands.
The cab doors will be provided with both interior (rotary knob) and exterior (keyed) locks
exceeding FMVSS standards. The keys will be Model 751. The locks will be capable of activating
when the doors are open or closed. The doors will remain locked if locks are activated when the
doors are opened, then closed.
A full length, heavy duty, stainless steel, piano-type hinge with a 0.38" pin and 11 gauge leaf will
be provided on all cab doors. There will be double automotive-type rubber seals around the
perimeter of the door framing and door edges to ensure a weather-tight fit.
A chrome handle will be provided on the inside of each front cab door for ease of entry.
The bottom cab step at each cab door location will be located below the cab doors and will be
exposed to the exterior of the cab.
15377Bid #:
PROPOSAL NO. 81217-18Exterior Door Handle
Interior Door Handle
0655543 Door Panel, Brushed Stainless Steel,
Saber/Enforcer 4-Door Cab
DOOR PANELS
The inner cab door panels will be constructed out of brushed stainless steel.
0630636 Controls, Electric Roll-Up Windows,
4dr, 4 Driver Controls, Saber
FR/Enforcer
ELECTRIC OPERATED CAB DOOR WINDOWS
All four (4) cab doors will be equipped with electric operated windows with one (1) flush mounted
automotive style switch on each door. The driver's door will have four (4) switches, one (1) to
control each door window.
Each switch will allow intermittent or auto down operation for ease of use. Auto down operation
will be actuated by holding the window down switch for approximately 1 second.
0638310 Steps, 4-Door Cab, Saber
FR/Enforcer
CAB STEPS
The forward cab and crew cab access steps will be a full size two (2) step design to provide
largest possible stepping surfaces for safe ingress and egress. The bottom steps will be designed
with a grip pattern punched into bright aluminum treadplate material to provide support, slip
resistance, and drainage. The bottom steps will be a bolt-in design to minimize repair costs
should they need to be replaced. The forward cab steps will be a minimum 25.00" wide, and the
crew cab steps will be 21.65" wide with a 10.00" minimum depth. The inside cab steps will not
exceed 16.50" in height.
The vertical surfaces of the step well will be aluminum treadplate.
0770194 Handrail, Exterior, Knurled, Alum, 4-
Door Cab
CAB EXTERIOR HANDRAILS
A 1.25" diameter slip-resistant, knurled aluminum handrail will be provided adjacent to each cab
and crew cab door opening to assist during cab ingress and egress.
16377Bid #:
PROPOSAL NO. 81217-180634786 Lights, Cab and Crew Cab Access
Steps, P25, LED w/Bezel, 1Lt Per
Step 6lts
STEP LIGHTS
There shall be six (6) white LED step lights installed for cab and crew cab access steps.
One (1) light for the driver's access steps.
Two (2) lights for the driver's side crew cab access steps.
Two (2) lights for the passenger's side crew cab access steps.
One (1) light for the passenger's side access step.
In order to ensure exceptional illumination, each light shall provide a minimum of 25 foot-candles
(fc) covering an entire 15" x 15" square placed ten (10) inches below the light and a minimum of
1.5 fc covering an entire 30" x 30" square at the same ten (10) inch distance below the light.
The lights shall be activated when the battery switch is on and the adjacent door is opened.
0040475 Crowns, Front Fender, Rubber FENDER CROWNS
Rubber fender crowns will be provided around the cab wheel openings.
Crowns will be black.
0042105 No Windows, Side of Crew Cab
0022260 Roof, Aluminum Treadplate
CAB ROOF COVERING
Horizontal cab roof surfaces will be covered with bright aluminum treadplate. The fastening
screws and the perimeter between the roof and the bottom of the aluminum treadplate, no more
than 1.00" in from the edge of the aluminum treadplate, will be properly caulked to prevent water
from leaking under aluminum. Front and side warning lights will not be mounted on top of
treadplate. The treadplate will extend and terminate next to the warning lights.
0553057 Holder, Cup, Cab/Crewcab, Each
CUP HOLDER
There will be four (4) cup holder(s) provided. Each cup holder will have self-adjusting fingers that
automatically grip beverage containers of various sizes. A recess in the cup holder will allow it to
hold beverage containers with handles.
The cup holder(s) will be located at customer pick-up.
0618351 Glove Box, Front of Officer, Saber
FR/Enforcer
GLOVE BOX
A glove box with a drop-down door will be installed above the recessed area of the dash panel in
front of the officer's position. The glove box will be 31.00" wide at the top and 24.75" at the
bottom x 5.50" high x 6.25" deep.
0607217 Mounting Provisions, 3/16" Alum, Full
Engine Tunnel, Saber FR/Enforcer
MOUNTING PLATE ON ENGINE TUNNEL
Equipment installation provisions will be installed on the engine tunnel.
A 0.188" smooth aluminum plate will be bolted to the top surface of the engine tunnel. The plate
will follow the contour of the engine tunnel and will run the entire length of the engine tunnel. The
plate will be spaced off the engine tunnel 1.00" to allow for wire routing below the plate.
The mounting surface will be painted to match the cab interior.
0657893 Mounting Plate, 3/16" Aluminum, Cab
Interior
MOUNTING PLATE(S)
There will be one (1)cover the entire width and height of the compartment 0.188" aluminum
mounting plate(s) provided and installed covering the entire forward wall (between the cabinet
and officer seat) of the PS rear facing EMS compartment. The mounting surface will be painted to
match the cab interior. The plates(s) will be mounted on 1.00" spacer stand-offs.
0797212 Cab Interior, Vinyl Headliner, Saber
FR/Enforcer, CARE
CAB INTERIOR
The cab interior will be constructed of primarily metal (painted aluminum) to withstand the severe
duty cycles of the fire service.
The officer side dash will be a flat faced design to provide easy maintenance and will be
constructed out of painted aluminum.
The instrument cluster will be surrounded with a high impact ABS plastic contoured to the same
shape of the instrument cluster.
The engine tunnel will be painted aluminum to match the cab interior.
For durability and ease of maintenance, the cab interior side walls will be painted aluminum. The
rear wall will be painted aluminum.
The headliner will be installed in both forward and rear cab sections. Headliner material will be
vinyl. A sound barrier will be part of its composition. Material will be installed on an aluminum
sheet and securely fastened to interior cab ceiling.
The forward portion of the cab headliner will permit easy access for service of electrical wiring or
other maintenance needs.
All wiring will be placed in metal raceways.
CAB INTERIOR UPHOLSTERY
The cab interior upholstery will be dark silver gray.
0012430 Cab Interior, paint color
CAB INTERIOR PAINT
A rich looking interior will be provided by painting all the metal surfaces inside the cab fire smoke
gray, vinyl texture paint.
17377Bid #:
PROPOSAL NO. 81217-180052100 Floor, Rubber Padded, Cab & Crew
Cab, Saber/Enforcer
CAB FLOOR
The cab and crew cab floor areas will be covered with Polydamp™ acoustical floor mat consisting
of a black pyramid rubber facing and closed cell foam decoupler.
The top surface of the material has a series of raised pyramid shapes evenly spaced, which offer
a superior grip surface. Additionally, the material has a 0.25" thick closed cell foam (no water
absorption) which offers a sound dampening material for reducing sound levels.
0644195 Heater/Defroster, Saber FR/Enforcer
CAB DEFROSTER
To provide maximum defrost and heating performance, a 43,500 BTU heater-defroster unit with
350 CFM of air flow will be provided inside the cab. The defroster unit will be strategically located
under the center forward portion of the vacuum formed instrument panel. For easy access, a
removable vacuum formed cover will be installed over the defroster unit. The defroster will
include an integral aluminum frame air filter, high performance dual scroll blowers, and ducts
designed to provide maximum defrosting capabilities for the 1-piece windshield. The defroster
ventilation will be built into the design of the cab dash instrument panel and will be easily
removable for maintenance. The defroster will be capable of clearing 98 percent of the windshield
and side glass when tested under conditions where the cab has been cold soaked at 0 degrees
Fahrenheit for 10 hours, and a 2 ounce per square inch layer of frost/ice has been able to build
up on the exterior windshield. The defroster system will meet or exceed SAE J382 requirements.
CAB/CREW CAB HEATER
Two (2) 44,180 BTU auxiliary heaters with 276 CFM (each unit) of air flow will be provided inside
the crew cab, one (1) in each outboard rear-facing seat riser. The heaters will include high
performance dual scroll blowers, one (1) for each unit. Outlets for the heaters will be located
below each rear facing seat riser and below the fronts of the driver and passenger seats, for
efficient airflow. An extruded aluminum plenum will be incorporated in the cab structure that will
transfer heat to the forward cab seating positions.
The heater/defroster and crew cab heaters will be controlled by a single integral electronic control
panel. The heater control panel will allow the driver to control heat flow to the front and rear
simultaneously. The control panel will include variable adjustment for temperature and fan
control, and be conveniently located on the dash in clear view of the driver. The control panel will
include highly visible, progressive LED indicators for both fan speed and temperature.
18377Bid #:
PROPOSAL NO. 81217-180644194 Air Conditioning, Saber FR/Enforcer
AIR CONDITIONING
A high performance, customized air conditioning system will be furnished inside the cab and crew
cab.
The air conditioning system will be capable of cooling the average cab temperature from 100
degrees Fahrenheit to 75 degrees Fahrenheit within 30 minutes at 50 percent relative humidity.
The cooling performance test will be run only after the cab has been heat soaked at 100 degrees
Fahrenheit for a minimum of 4 hours.
A radiator mounted condenser with a 59,644 BTU output that meets and exceed the performance
specification will be installed.
One (1) evaporator unit will be installed in the center roof with two (2) cores, one (1) for the cab
and one (1) for the crew cab. The evaporator unit will have an adequate BTU rating to meet the
performance specifications.
Adjustable air outlets will be strategically located on the evaporator cover per the following:
Four (4) will be directed towards the driver's location
Four (4) will be directed towards the officer's location
Seven (7) will be directed towards the crew cab area
The air conditioner refrigerant will be R-134A and will be installed by a certified technician.
The air conditioner will be controlled by a single electronic control panel. For ease of operation,
the control panel will include variable adjustment for temperature and fan control and be
conveniently located on the dash in clear view of the driver.
Gravity Drain Tubes
Two (2) condensate drain tubes will be provided for the air conditioning evaporator. The drip pan
will have two (2) drain tubes plumbed separately to allow for the condensate to exit the drip pan.
No pumps will be provided.
0624005 Sun Visor, Vinyl/Fabric, AXT, Dash
CF, Qtm, Saber FR/Enforcer
SUN VISORS
There will be two (2) vinyl covered sun visors provided. The sun visors will be located above the
windshield with one (1) mounted on each side of the cab.
There will be no retention bracket provided to help secure each sun visor in the stowed position.
0634328 Grab Handles, Driver and Officer
Door Posts, Saber FR/Enforcer
GRAB HANDLES
A black rubber covered grab handle will be mounted on the door post of the driver and officer's
side cab door to assist in entering the cab. The grab handles will be securely mounted to the post
area between the door and windshield.
19377Bid #:
PROPOSAL NO. 81217-180583938 Lights, Engine Compt, Custom, Auto
Sw, Wln 3SC0CDCR, 3" LED, Trim
ENGINE COMPARTMENT LIGHTS
There will be one (1) Whelen, Model 3SC0CDCR, 12 volt DC, 3.00" white LED light(s) with
Whelen, Model 3FLANGEC, chrome flange kit(s) installed under the cab to be used as engine
compartment illumination.
These light(s) will be activated automatically when the cab is raised.
0631830 Fluid Check Access, Saber
FR/Enforcer, Arrow XT
ACCESS TO ENGINE DIPSTICKS
For access to the engine oil and transmission fluid dipsticks, there will be a door on the engine
tunnel, inside the crew cab. The door will be on the rear wall of the engine tunnel, on the vertical
surface.
The engine oil dipstick will allow for checking only. The transmission dipstick will allow for both
checking and filling.
The door will have a rubber seal for thermal and acoustic insulation. One (1) flush latch will be
provided on the access door.
0002501 Map box, 4 bin/30 Deg Slant, Custom
Chassis
MAP BOX
A map box with four (4) bins, open from top, will be installed ship loose and mount at final
inspection. The map box will be divided into four (4) bins, each being 12.50" wide x 2.25" high x
12.00" deep. Each bin will slant 30 degrees from horizontal. The map box will be constructed of
.125" aluminum and will be painted to match the cab interior.
20377Bid #:
PROPOSAL NO. 81217-180583042 Side Roll and Frontal Impact
Protection
CAB SAFETY SYSTEM
The cab will be provided with a safety system designed to protect occupants in the event of a
side roll or frontal impact, and will include the following:
A supplemental restraint system (SRS) sensor will be installed on a structural cab member
behind the instrument panel. The SRS sensor will perform real time diagnostics of all critical
subsystems and will record sensory inputs immediately before and during a side roll or frontal
impact event.
A slave SRS sensor will be installed in the cab to provide capacity for eight (8) crew cab seating
positions.
A fault-indicating light will be provided on the vehicle's instrument panel allowing the driver to
monitor the operational status of the SRS system.
A driver side front air bag will be mounted in the steering wheel and will be designed to protect
the head and upper torso of the occupant, when used in combination with the 3-point seat belt.
A passenger side knee bolster air bag will be mounted in the modesty panel below the dash
panel and will be designed to protect the legs of the occupant, when used in combination with the
3-point seat belt.
Air curtains will be provided in the outboard bolster of outboard seat backs to provide a cushion
between occupant and the cab wall.
Suspension seats will be provided with devices to retract them to the lowest travel position during
a side roll or frontal impact event.
Seat belts will be provided with pre-tensioners to remove slack from the seat belt during a side
roll or frontal impact event.
FRONTAL IMPACT PROTECTION
The SRS system will provide protection during a frontal or oblique impact event. The system will
activate when the vehicle decelerates at a predetermined G force known to cause injury to the
occupants. The cab and chassis will have been subjected, via third party test facility, to a crash
impact during frontal and oblique impact testing. Testing included all major chassis and cab
components such as mounting straps for fuel and air tanks, suspension mounts, front suspension
components, rear suspensions components, frame rail cross members, engine and transmission
and their mounts, pump house and mounts, frame extensions and body mounts. The testing
provided configuration specific information used to optimize the timing for firing the safety
restraint system. The sensor will activate the pyrotechnic devices when the correct crash
algorithm, wave form, is detected.
The SRS system will deploy the following components in the event of a frontal or oblique impact
event:
Driver side front air bag
Passenger side knee bolster air bag
Air curtains mounted in the outboard bolster of outboard seat backs
Suspension seats will be retracted to the lowest travel position
Seat belts will be pre-tensioned to firmly hold the occupant in place
SIDE ROLL PROTECTION
The SRS system will provide protection during a fast or slow 90 degree roll to the side, in which
the vehicle comes to rest on its side. The system will analyze the vehicle's angle and rate of roll
to determine the optimal activation of the advanced occupant restraints.
The SRS system will deploy the following components in the event of a side roll:
Air curtains mounted in the outboard bolster of outboard seat backs
Suspension seats will be retracted to the lowest travel position
Seat belts will be pre-tensioned to firmly hold the occupant in place
0622619 Seating Capacity, 4 Seats
SEATING CAPACITY
The seating capacity in the cab will be four (4).
0636955 Seat, Driver, Pierce PSV, Air Ride,
High Back, Safety, Saber
FR/Enforcer
DRIVER SEAT
A seat will be provided in the cab for the driver. The seat design will be a cam action type, with air
suspension. For increased convenience, the seat will include a manual control to adjust the
horizontal position (6.00" travel). The manual horizontal control will be a towel-bar style located
below the forward part of the seat cushion. To provide flexibility for multiple driver configurations,
the seat will have an adjustable reclining back. The seat back will be a high back style with side
bolster pads for maximum support. For optimal comfort, the seat will be provided with 17.00"
deep foam cushions designed with EVC (elastomeric vibration control).
The seat will include the following features incorporated into the side roll protection system:
Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain
will be covered by a decorative panel when in the stowed position.
A suspension seat safety system will be included. When activated in the event of a side roll, this
system will pretension the seat belt and retract the seat to its lowest travel position.
The seat will be furnished with a 3-point, shoulder type seat belt.
0632924 Seat, Officer, Pierce PSV, Air Ride,
High Back, Safety, Saber
FR/Enforcer
OFFICER SEAT
A seat will be provided in the cab for the passenger. The seat design will be a cam action type
with air suspension. The seat back will be a high back style with 9 degree fixed recline angle and
side bolster pads for maximum support. For optimal comfort, the seat will be provided with 17.00"
deep foam cushions designed with EVC (elastomeric vibration control).
The seat will include the following features incorporated into the side roll protection system:
Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain
will be covered by a decorative panel when in the stowed position.
A suspension seat safety system will be included. When activated, this system will pretension the
seat belt and then retract the seat to its lowest travel position.
The seat will be furnished with a 3-point, shoulder type seat belt.
0002517 Not Required, Radio Compartment
21377Bid #:
PROPOSAL NO. 81217-180757997 Cabinet, Rear Facing, LS, 23 W x
40.25 H x 26.75 D, Lap, Ext Acc,
SFR/Enf
REAR FACING LEFT SIDE EMS CABINET
A rear facing cabinet will be provided in the crew cab at the left side outboard position.
The cabinet will be 23.00" wide x 40.25" high x 26.75" deep with one (1) lap door hinged on the
outboard side, painted to match the cab interior with two (2) non-locking D-ring latches. The
interior clear door opening of the cabinet will be 16.00" wide x 37.75" high.
The cabinet will also provide access from outside the cab with one (1) double pan door painted to
match the cab exterior with a locking D-ring latch with #751 key. A rubber bumper will be provided
as a door stop. The door will be located on the side of the cab over the wheelwell. The clear door
opening will be 17.25" wide x 33.75" high.
The cabinet will include two (2) infinitely adjustable shelves with a 1.25" up-turned lippainted to
match the cab interior.
The cabinet will include no louvers.
The exterior access will be provided with a polished stainless steel scuffplate on the lower door
frame.
The cabinet will be constructed of smooth aluminum and painted to match the cab interior.
Cabinet Light
There will be one (1) white LED strip light installed on the right side of the interior cabinet door
opening and one (1) white LED strip light installed on the left side of the interior cabinet door
opening. The lights will be controlled by an automatic door switch.
0102783 Not Required, Seat, Rr Facing C/C,
Center
0757966 Cabinet, Rear Facing, RS, 22 W x
40.25 H x 26.75 D, Lap, Ext Acc,
SFR/Enf
REAR FACING RIGHT SIDE CABINET
A rear facing cabinet will be provided in the crew cab at the right side outboard position.
The cabinet will be 22.00" wide x 40.25" high x 26.75" deep with one (1) lap door hinged on the
outboard side, painted to match the cab interior with two (2) non-locking D-ring latches. The clear
door opening of the cabinet will be 15.00" wide x 37.25" high.
The cabinet will include two (2) infinitely adjustable shelves with a 1.25" up-turned lippainted to
match the cab interior.
The cabinet will include no louvers.
The cabinet will also provide access from outside the cab with one (1) double pan door painted to
match the cab exterior with a locking D-ring latch with #751 key. A rubber bumper will be provided
as a door stop. The exterior clear door opening will be 17.25" wide x 33.75" high.
The exterior access will be provided with a polished stainless steel scuffplate on the lower door
frame.
The cabinet will be constructed of smooth aluminum, and painted to match the cab interior.
Cabinet Light
There will be one (1) white LED strip light installed on the right side of the interior cabinet door
opening and one (1) white LED strip light installed on the left side of the interior cabinet door
opening. The lights will be controlled by an automatic door switch.
0108189 Not Required, Seat, Forward Facing
C/C, DS Outboard
0757350 SP Seat, Forward Fcng C/C, Ctr, (2)
Pierce PSV, Hi-
Back,Foldup,Safety,Riser,SFR/Enf
FORWARD FACING CENTER SEATS
There will be two (2) forward facing foldup seats provided at the center position in the crew cab.
The seat back will be a high back style with 9 degree fixed recline angle. For optimal comfort, the
seats will be provided with 15.00" deep foam cushions designed with EVC (elastomeric vibration
control).
The seats will include the following feature incorporated into the side roll protection system:
A seat safety system will be included. When activated, this system will pretension the seat belts
around the occupants to firmly hold them in place in the event of a side roll.
The seats will be furnished with a 3-point, shoulder type seat belt.
Forward Facing Center Seat Riser
A seat riser cabinet will be provided in the center forward facing position.
There will be an access door provided on the front of the forward facing seat riser. The door will
be hinged with two (2) non-locking, flush lift and turn latches.
0108190 Not Required, Seat, Forward Facing
C/C, PS Outboard
0558255 Trim, Polished S/S Scuffplate, Outer
Edges Of Cabinet Door Opening
CABINET TRIM
The outer edges of the cabinet door opening will be covered with polished stainless steel. The
top, bottom, and sides will be included. There will be two (2) door opening(s) being trimmed DS
and PS EMS cabinets.
0617401 Matting, Turtle Tile, No Trim, EMS
Compt
MATTING IN EMS COMPARTMENT
Vinyl grating will be provided in four (4) EMS compartments, DS and PS . Tile color will be black.
The vinyl grating will be 0.50" thick and be cross bonded by 0.25" diameter ribbed sections
spaced for aeration. The trim edge will not be installed at the edge of the tile.
0617410 Matting, Turtle Tile, EMS Compt,
Shelving, 0.75" Thick
MATTING IN EMS COMPARTMENT
Turtle Tile vinyl matting will be provided in two (2) EMS compartment shelves, DS and PS EMS
compt. . Tile color will be black.
22377Bid #:
PROPOSAL NO. 81217-180042359 Upholstery, Seats In Cab, All Vinyl,
CARE
SEAT UPHOLSTERY
All seat upholstery will be 46 ounce leather grain black vinyl resistant to oil, grease and mildew.
The cab will have four (4) seating positions.
0511471 No SCBA Brackets Required In Cab
Seats, Imp/Vel, AXT 2010, Qtm 2010,
Dash CF
0681146 Door, Access, Each Side, Forward
Facing Seat Riser
ACCESS DOORS
An access door will be provided on both sides of the forward facing seat riser in crew cab. Doors
will be constructed out of same material as seat riser with one (1) 1/4 turn flush latch on each
door.
0603866 Seat Belt, Dual Retractor,
ReadyReach, Saber FR/Enforcer
SEAT BELTS
All cab and tiller cab (if applicable) seating positions will have red seat belts. To provide quick,
easy use for occupants wearing bunker gear, the female buckle and seat belt webbing length will
meet or exceed the current edition of NFPA 1901 and CAN/ULC - S515 standards.
The 3-point shoulder type seat belts will include height adjustment. This adjustment will optimize
the belts effectiveness and comfort for the seated firefighter. The 3-point shoulder type seat belts
will be furnished with dual automatic retractors that shall provide ease of operation in the normal
seating position.
The 3-point shoulder type belts will also include the ReadyReach D-loop assembly to the
shoulder belt system. The ReadyReach feature adds an extender arm to the D-loop location
placing the D-loop in a closer, easier to reach location.
To ensure safe operation, the seats will be equipped with seat belt sensors in the seat cushion
and belt receptacle that shall activate an alarm indicating a seat is occupied but not buckled.
0602464 Helmet Storage, Provided by Fire
Department, NFPA 2016
HELMET STORAGE PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, section 14.1.7.4.1 requires a location for helmet storage be provided.
There is no helmet storage on the apparatus as manufactured. The fire department will provide a
location for storage of helmets.
0647647 Lights, Dome, FRP Dual LED 4 Lts
CAB DOME LIGHTS
There will be four (4) dual LED dome lights with black bezels provided. Two (2) lights will be
mounted above the inside shoulder of the driver and officer and two (2) lights will be installed and
located, one (1) on each side of the crew cab.
The color of the LED's will be red and white.
The white LED's will be controlled by the door switches and the lens switch.
The color LED's will be controlled by the lens switch.
In order to ensure exceptional illumination, each white LED dome light will provide a minimum of
10.1 foot-candles (fc) covering an entire 20.00" x 20.00" square seating position when mounted
40.00" above the seat.
0626097 Light, Map, Sunnex HS76*-00 Series,
Swivel Joint, Clear Lens, Ceiling
Mount
MAP LIGHT
There will be one (1) Sunnex®, HS76*-00, halogen map light(s) with swivel joint base provided in
the cab and located over the front passenger seat, inboard of the provided red / clear push button
map light . Each map light will have a rectangular base with an on/off switch.
The light(s) will also be provided with no additional accessory.
The light switch(es) will be connected directly to the battery switched power.
0555812 Handlts, (2) Streamlight, Fire Vulcan,
44451 C4 LED, Tail lights, 12v,
Orange
HAND HELD LIGHT
There will be two (2) 12v Streamlight, Fire Vulcan, Model #44451, lights mounted to be mounted
in the rear passenger compartment, with wiring..
Each light housing will be orange in color and be provided with a C4 LED and two (2) "ultra bright
blue tail light LEDs" The tail light LEDs will have a dual mode of blinking or steady.
Vehicle mount with 12VDC direct wire charging rack.
Quick release buckle strap will be included.
0622803 Cab Instruments, Black Gauges,
Black Bezels, Enforcer MUX
CAB INSTRUMENTATION
The cab instrument panel will be a molded ABS panel and include gauges, an LCD display,
telltale indicator lamps, control switches, alarms, and a diagnostic panel. The function of the
instrument panel controls and switches will be identified by a label adjacent to each item.
Actuation of the headlight switch will illuminate the labels in low light conditions. Telltale indicator
lamps will not be illuminated unless necessary. The cab instruments and controls will be
conveniently located within the forward cab section, forward of the driver. The gauge assembly
and switch panels are designed to be removable for ease of service and low cost of ownership.
GAUGES
The gauge panel will include the following ten (10) black faced gauges with black bezels to
monitor vehicle performance:
Voltmeter gauge (volts):
Low volts (11.8 VDC)
Amber caution indicator on the information center with intermittent alarm
Amber caution light on gauge assembly
High volts (15.5 VDC)
23377Bid #:
PROPOSAL NO. 81217-18Amber caution indicator on the information center with intermittent alarm
Amber caution light on gauge assembly
Very low volts (11.3 VDC)
Red warning indicator on the information center with a steady alarm
Amber caution light on gauge assembly
Very high volts (16.0 VDC)
Red warning indicator on the information center with a steady alarm
Amber caution light on gauge assembly
Engine Tachometer (RPM)
Speedometer MPH (Major Scale), KM/H (Minor Scale)
Fuel level gauge (Empty - Full in fractions):
Low fuel (1/8 full)
Amber caution indicator on the information center with intermittent alarm
Amber caution light on gauge assembly
Very low fuel (1/32 full)
Red caution indicator on the information center with steady alarm
Amber caution light on gauge assembly
Engine Oil pressure Gauge (PSI):
Low oil pressure to activate engine warning lights and alarms
Red caution indicator on the information center with steady alarm
Amber caution light on gauge assembly
Front Air Pressure Gauges (PSI):
Low air pressure to activate warning lights and alarm
Red warning indicator on the information center with a steady alarm
Amber caution light on gauge assembly
Rear Air Pressure Gauges (PSI):
Low air pressure to activate warning lights and alarm
Red warning indicator on the information center with a steady alarm
Amber caution light on gauge assembly
Transmission Oil Temperature Gauge (Fahrenheit):
High transmission oil temperature activates warning lights and alarm
Amber caution indicator on the information center with intermittent alarm
Amber caution light on gauge assembly
Engine Coolant Temperature Gauge (Fahrenheit):
High engine temperature activates an engine warning light and alarms
Amber caution indicator on the information center with intermittent alarm
Amber caution light on gauge assembly
Diesel Exhaust Fluid Level Gauge (Empty - Full in fractions):
Low fluid (1/8 full)
Amber indicator light in gauge dial
All gauges will perform prove out at initial power-up to ensure proper performance.
INDICATOR LAMPS
To promote safety, the following telltale indicator lamps will be located on the instrument panel in
clear view of the driver. The indicator lamps will be "dead-front" design that is only visible when
active. The colored indicator lights will have descriptive text or symbols.
The following amber telltale lamps will be present:
Low coolant
Trac cntl (traction control) (where applicable
Check engin
Check trans (check transmission
Aux brake overheat (Auxiliary brake overheat
Air rest (air restriction)
Caution (triangle symbol)
Water in fuel
DPF (engine diesel particulate filter regeneration)
Trailer ABS (where applicable)
Wait to start (where applicable)
HET (engine high exhaust temperature) (where applicable)
ABS (antilock brake system)
MIL (engine emissions system malfunction indicator lamp) (where applicable)
Side roll fault (where applicable)
Front air bag fault (where applicable)
The following red telltale lamps will be present:
Warning (stop sign symbol)
Seat belt
Parking brake
Stop engine
Rack down
The following green telltale lamps will be provided:
Left turn
Right turn
Battery on
The following blue telltale lamp will be provided:
High beam
ALARMS
Audible steady tone warning alarm: A steady audible tone alarm will be provided whenever a
warning message is present.
Audible pulsing tone caution alarm: A pulsing audible tone alarm (chime/chirp) will be provided
whenever a caution message is present without a warning message being present.
Alarm silence: Any active audible alarm will be able to be silenced by holding the ignition switch
at the top position for three (3) to five (5) seconds. For improved safety, silenced audible alarms
will intermittently chirp every 30 seconds until the alarm condition no longer exists. The
intermittent chirp will act as a reminder to the operator that a caution or warning condition still
exists. Any new warning or caution condition will enable the steady or pulsing tones respectively.
INDICATOR LAMP AND ALARM PROVE-OUT
A system will be provided which automatically tests telltale indicator lights and alarms
located on the cab instrument panel. Telltale indicators and alarms will perform prove-out
at initial power-up to ensure proper performance.
24377Bid #:
PROPOSAL NO. 81217-18CONTROL SWITCHES
For ease of use, the following controls will be provided immediately adjacent to the cab
instrument panel within easy reach of the driver. All switches will have backlit labels for
low light applications.
Headlight/Parking light switch: A three (3)-position maintained rocker switch will be
provided. The first switch position will deactivate all parking and headlights. The second
switch position will activate the parking lights. The third switch will activate the
headlights.
Panel back lighting intensity control switch: A three (3)-position momentary rocker switch
will be provided. Pressing the top half of the switch, "Panel Up" increases the panel back
lighting intensity and pressing the bottom half of the switch, "Panel Down" decreases the
panel back lighting intensity. Pressing the half or bottom half of the switch several times
will allow back lighting intensity to be gradually varied from minimum to maximum
intensity level for ease of use.
Ignition switch: A three (3)-position maintained/momentary rocker switch will be provided.
The first switch position will turn off and deactivate vehicle ignition. The second switch
position will activate vehicle ignition and will perform prove-out on the telltale indicators
and alarms for 3 to 5 seconds after the switch is turned on. A green indicator lamp is
activated with vehicle ignition. The third momentary position will temporarily silence all
active cab alarms. An alarm "chirp" may continue as long as alarm condition exists.
Switching ignition to off position will terminate the alarm silence feature and reset
function of cab alarm system.
Engine start switch: A two (2)-position momentary rocker switch will be provided. The first
switch position is the default switch position. The second switch position will activate the
vehicle's engine. The switch actuator is designed to prevent accidental activation.
Hazard switch will be provided on the instrument panel or on the steering column.
Heater, defroster, and optional air conditioning control panel: A control panel with
membrane switches will be provided to control heater/defroster temperature and heater,
defroster, and air conditioning fan speeds. A green LED status bar will indicate the
relative temperature and fan speed settings.
Turn signal arm: A self-canceling turn signal with high beam headlight and windshield
wiper/washer controls will be provided. The windshield wiper control will have high, low,
and intermittent modes.
Parking brake control: An air actuated push/pull park brake control valve will be provided.
Chassis horn control: Activation of the chassis horn control will be provided through the
center of the steering wheel.
High idle engagement switch: A momentary rocker switch with integral indicator lamp will
be provided. The switch will activate and deactivate the high idle function. The "OK To
Engage High Idle" indicator lamp must be active for the high idle function to engage. A
green indicator lamp integral to the high idle engagement switch will indicate when the
high idle function is engaged.
"OK To Engage High Idle" indicator lamp: A green indicator light will be provided next to
the high idle activation switch to indicate that the interlocks have been met to allow high
idle engagement.
Emergency switching will be controlled by multiple individual warning light switches for
various groups or areas of emergency warning lights. An Emergency Master switch
provided on the instrument panel that enables or disables all individual warning light
switches is included.
An additional "Emergency Master" button will be provided on the lower left hand corner of
the gauge panel to allow convenient control of the "Emergency Master" system from
inside the driver's door when standing on the ground.
CUSTOM SWITCH PANELS
The design of cab instrumentation will allow for emergency lighting and other switches to
be placed within easy reach of the operator thus improving safety. There will be positions
for up to four (4) switch panels in the lower instrument console and up to six (6) switch
panels in the overhead visor console. All switches have backlit labels for low light
conditions.
DIAGNOSTIC PANEL
A diagnostic panel will be accessible while standing on the ground and located inside the
driver's side door left of the steering column. The diagnostic panel will allow diagnostic
tools such as computers to connect to various vehicle systems for improved
troubleshooting providing a lower cost of ownership. Diagnostic switches will allow ABS
systems to provide blink codes should a problem exist.
The diagnostic panel will include the following:
Engine diagnostic port
Transmission diagnostic port
ABS diagnostic port
Roll sensor diagnostic port
Command Zone USB diagnostic port
ABS diagnostic switch (blink codes flashed on ABS telltale indicator)
Diesel particulate filter regeneration switch (where applicable)
Diesel particulate filter regeneration inhibit switch (where applicable)
CAB LCD DISPLAY
A digital four (4)-row by 20-character dot matrix display will be integral to the gauge panel.
The display will be capable of showing simple graphical images as well as text. The
display will be split into three (3) sections. Each section will have a dedicated function.
The upper left section will display the outside ambient temperature.
The upper right section will display the following, along with other configuration specific
information:
Odometer
Trip mileage
PTO hours
Fuel consumption
Engine hours
The bottom section will display INFO, CAUTION, and WARNING messages. Text messages
will automatically activate to describe the cause of an audible caution or warning alarm.
The LCD will be capable of displaying multiple text messages should more than one
caution or warning condition exist.
25377Bid #:
PROPOSAL NO. 81217-180509511 Air Restriction Indicator, Imp/Vel,
AXT, Dash CF, Enf MUX
AIR RESTRICTION INDICATOR
A high air restriction warning indicator light LCD message with amber warning indicator and
audible alarm shall be provided.
0673123 Light, Do Not Move Apparatus, Wln
3SR00FRR LED
"DO NOT MOVE APPARATUS" INDICATOR
A Whelen Model 3SR00FRR flashing red LED indicator light with a Whelen, Model 3FLANGEC
chrome surface mount flange located in the driving compartment, will be illuminated automatically
per the current NFPA requirements. The light will be labeled "Do Not Move Apparatus If Light Is
On".
The same circuit that activates the Do Not Move Apparatus indicator will activate a steady tone
alarm when the parking brake is released.
0509042 Messages, Open Door/Do Not Move
Truck, MUX w/Color Display
DO NOT MOVE TRUCK MESSAGES
Messages will be displayed on the Command Zone™, color display located within sight of the
driver whenever the Do Not Move Truck light is active. The messages will designate the item or
items not in the stowed for vehicle travel position (parking brake disengaged).
The following messages will be displayed (where applicable):
Do Not Move Truck
DS Cab Door Open (Driver Side Cab Door Open)
PS Cab Door Open (Passenger's Side Cab Door Open)
DS Crew Cab Door Open (Driver Side Crew Cab Door Open)
PS Crew Cab Door Open (Passenger's Side Crew Cab Door Open)
DS Body Door Open (Driver Side Body Door Open)
PS Body Door Open (Passenger's Side Body Door Open)
Rear Body Door Open
DS Ladder Rack Down (Driver Side Ladder Rack Down)
PS Ladder Rack Down (Passenger Side Ladder Rack Down)
Deck Gun Not Stowed
Lt Tower Not Stowed (Light Tower Not Stowed)
Fold Tank Not Stowed (Fold-A-Tank Not Stowed)
Aerial Not Stowed (Aerial Device Not Stowed)
Stabilizer Not Stowed
Steps Not Stowed
Handrail Not Stowed
Any other device that is opened, extended, or deployed that creates a hazard or is likely to cause
major damage to the apparatus if the apparatus is moved will be displayed as a caution message
after the parking brake is disengaged.
0611683 Switching, Cab Instrument Lower
Console & Overhead, Membrane,
Enforcer WiFi MUX
SWITCH PANELS
The emergency light switch panel will have a master switch for ease of use plus individual
switches for selective control. Each switch panel will contain eight (8) membrane-type switches
each rated for one million (1,000,000) cycles. Panels containing less than eight (8) switch
assignments will include non-functioning black appliqués. The built-in switch panels will be
located in the lower console or overhead console of the cab.
Additional switch panel(s) will be located in the overhead position(s) above the windshield or in
designated locations on the lower instrument panel layout.
The switches will be membrane-type and also act as an integral indicator light. For quick, visual
indication the entire surface of the switch will be illuminated white whenever back lighting is
activated and illuminated green whenever the switch is active. An active illuminated switch will
flash when interlock requirements are not met or device is actively being load managed. For ease
of use, a two (2)-ply, scratch resistant laser engraved Gravoply label indicating the use of each
switch will be placed in the center of the switch. The label will allow light to pass through the
letters for ease of use in low light conditions.
0644179 Wiper Control, 2-Speed with
Intermittent, Saber FR/Enforcer
WIPER CONTROL
Wiper control will consist of a two (2)-speed windshield wiper control with intermittent feature and
windshield washer controls.
0548004 Wiring, Spare, 15 A 12V DC 1st
SPARE CIRCUIT
There will be four (4) pair of wires, including a positive and a negative, installed on the apparatus.
The above wires will have the following features:
The positive wire will be connected directly to the battery power
The negative wire will be connected to ground
Wires will be protected to 15 amps at 12 volts DC
Power and ground will terminate officer side dash area, in the center console and in a seperate
box on the OUTBOARD side of both the DS and PS EMS cabinet inside the cab. USB receptacle
will also be located in this seperate box each side.
Termination will be with 15 amp, power point plug with rubber cover
Wires will be sized to 125 percent of the protection
The circuit(s) may be load managed when the parking brake is set.
26377Bid #:
PROPOSAL NO. 81217-180548009 Wiring, Spare, 20 A 12V DC 1st
SPARE CIRCUIT
There will be one (1) pair of wires, including a positive and a negative, installed on the apparatus.
The above wires will have the following features:
The positive wire will be connected directly to the battery power
The negative wire will be connected to ground
Wires will be protected to 20 amps at 12 volts DC
Power and ground will terminate on top of the rear engine tunnel w/ a 20' loom for customer
routing. Location TBD @ final inspection (for customer TIC, gas monitor, 5 portable chargers,
MDC)
Termination will be with a 10-place bus bar with screws and removable cover
Wires will be sized to 125% of the protection
This circuit(s) may be load managed when the parking brake is set.
0594194 Radio, AM/FM/CD/WB/Aux in,
Panasonic
RADIO WITH CD PLAYER
There will be a Panasonic™, AM/FM/Weather Band stereo radio with compact disc player and
auxiliary input jack installed.
The compact disc stereo radio will be mounted within reach of the officer.
The quantity and location of the speakers will be one (1) pair of 5.25" speakers in the cab and
one (1) pair of 5.25" speakers in the crew cab.
The type and location of the antenna will be a roof-mounted rubber antenna located in an open
space, on the cab roof.
0615386 Vehicle Information Center, 7" Color
Display, Touchscreen, MUX
INFORMATION CENTER
An information center employing a 7.00" diagonal touch screen color LCD display will be encased
in an ABS plastic housing.
The information center will have the following specifications:
Operate in temperatures from -40 to 185 degrees Fahrenheit
An Optical Gel will be placed between the LCD and protective lens
Five weather resistant user interface switches
Grey with black accents
Sunlight Readable
Linux operating system
Minimum of 1000nits rated display
Display can be changed to an available foreign language
A LCD display integral to the cab gauge panel will be included as outlined in the cab
instrumentation area.
Programmed to read US Customary
GENERAL SCREEN DESIGN
Where possible, background colors will be used to provide "At a Glance" vehicle information. If
information provided on a screen is within acceptable limits, a green background will be used.
If a caution or warning situation arises the following will occur:
An amber background/text color will indicate a caution condition
A red background/text color will indicate a warning condition
The information center will utilize an "Alert Center" to display text messages for audible alarm
tones. The text messages will be written to identify the item(s) causing the audible alarm to
sound. If more than one (1) text message occurs, the messages will cycle every second until the
problem(s) have been resolved. The background color for the "Alert Center" will change to
indicate the severity of the "warning" message. If a warning and a caution condition occur
simultaneously, the red background color will be shown for all alert center messages.
A label for each button will exist. The label will indicate the function for each active button for
each screen. Buttons that are not utilized on specific screens will have a button label with no text
or symbol.
HOME/TRANSIT SCREEN
This screen will display the following:
Vehicle Mitigation (if equipped)
Water Level (if the water level system includes compatible communications to the information
center)
Foam Level (if the foam level system includes compatible communications to the information
center)
Seat Belt Monitoring Screen Seat Belt Monitoring Screen
Tire Pressure Monitoring (if equipped)
Digital Speedometer
Active Alarms
ON SCENE SCREEN
This screen will display the following and will be auto activated with pump engaged (if equipped):
Battery Voltage
Fuel
Oil Pressure
Coolant Temperature
RPM
Water Level (if equipped)
Foam Level (if equipped)
Foam Concentration (if equipped)
Water Flow Rate (if equipped)
Water Used (if equipped)
Active Alarms
VIRTUAL BUTTONS
There will be four (4) virtual switch panel screens that match the overhead and lower lighting and
HVAC switch panels.
PAGE SCREEN
The page screen will display the following and allow the user to progress into other screens for
further functionality:
Diagnostics
Faults
27377Bid #:
PROPOSAL NO. 81217-18Listed by order of occurrence
Allows to sort by system
Interlock
Throttle Interlocks
Pump Interlocks (if equipped)
Aerial Interlocks (if equipped)
PTO Interlocks (if equipped)
Load Manager
A list of items to be load managed will be provided. The list will provide a description of the load.
The lower the priority numbers the earlier the device will be shed should a low voltage condition
occur.
The screen will indicate if a load has been shed (disabled) or not shed.
"At a glance" color features are utilized on this screen.
Systems
Command Zone
Module type and ID number
Module Version
Input or output number
Circuit number connected to that input or output
Status of the input or output
Power and Constant Current module diagnostic information
Foam (if equipped)
Pressure Controller (if equipped)
Generator Frequency (if equipped)
Live Data
General Truck Data
Maintenance
Engine oil and filter
Transmission oil and filter
Pump oil (if equipped)
Foam (if equipped)
Aerial (if equipped)
Setup
Clock Setup
Date & Time
12 or 24 hour format
Set time and date
Backlight
Daytime
Night time
Sensitivity
Unit Selection
Home Screen
Virtual Button Setup
On Scene Screen Setup
Configure Video Mode
Set Video Contrast
Set Video Color
Set Video Tint
Do Not Move
The screen will indicate the approximate location and type of item that is open or is not stowed for
travel. The actual status of the following devices will be indicate
Driver Side Cab Door
Passenger's Side Cab Door
Driver Side Crew Cab Door
Passenger's Side Crew Cab Door
Driver Side Body Doors
Passenger's Side Body Doors
Rear Body Door(s)
Ladder Rack (if applicable)
Deck Gun (if applicable)
Light Tower (if applicable)
Hatch Door (if applicable)
Stabilizers (if applicable)
Steps (if applicable)
Notifications
View Active Alarms
Shows a list of all active alarms including date and time of the occurrence is shown with each
alarm
Silence Alarms - All alarms are silenced
Timer Screen
HVAC (if equipped)
Tire Information (if equipped)
Ascendant Set Up Confirmation (if equipped)
Button functions and button labels may change with each screen.
28377Bid #:
PROPOSAL NO. 81217-180606247 Vehicle Data Recorder w/CZ Display
Seat Belt Monitor
VEHICLE DATA RECORDER
There will be a vehicle data recorder (VDR) capable of reading and storing vehicle information
provided.
The information stored on the VDR can be downloaded through a USB port mounted in a
convenient location determined by cab model. A USB cable can be used to connect the VDR to a
laptop to retrieve required information. The program to download the information from the VDR
will be available to download on-line.
The vehicle data recorder will be capable of recording the following data via hardwired and/or
CAN inputs:
Vehicle Speed - MPH
Acceleration - MPH/sec
Deceleration - MPH/sec
Engine Speed - RPM
Engine Throttle Position - % of Full Throttle
ABS Event - On/Off
Seat Occupied Status - Yes/No by Position
Seat Belt Buckled Status - Yes/No by Position
Master Optical Warning Device Switch - On/Off
Time - 24 Hour Time
Date - Year/Month/Day
Seat Belt Monitoring System
A seat belt monitoring system (SBMS) will be provided on the Command Zone™ color display.
The SBMS will be capable of monitoring up to 10 seating positions indicating the status of each
seat position per the following:
Seat Occupied & Buckled = Green LED indicator illuminated
Seat Occupied & Unbuckled = Red LED indicator with audible alarm
No Occupant & Buckled = Red LED indicator with audible alarm
No Occupant & Unbuckled = No indicator and no alarm
The seat belt monitoring screen will become active on the Command Zone color display when:
The home screen is active:
and there is any occupant seated but not buckled or any belt buckled with an occupant.
and there are no other Do Not Move Apparatus conditions present. As soon as all Do Not Move
Apparatus conditions are cleared, the SBMS will be activated.
The SBMS will include an audible alarm that will warn that an unbuckled occupant condition
exists and the parking brake is released, or the transmission is not in park.
0620867 SP Intercom, Sigtronics US-45D-LAC, 4-
Pos, 2 Dual Radio D,O,2C
INTERCOM SYSTEM
There will be a voice activated intercom system with dual radio interface capability and one (1)
push-to-transmit button for each radio, two (2) each at the driver and officer positions. Both radios
will be heard at all times. Two (2) crew located at both forward facing seatswill have radio listen /
intercom only.
The following Sigtronics components will be provided:
One (1) US-45D-LAC Intercom system
Four (4) 800122 Push to transmit buttons in blue boxes
Four (4) 800120 Headset jacks in blue boxes
All necessary power and station wiring
0022898 Cable, Radio to Intercom Interface,
Sigtronics, 2 Radios
RADIO / INTERCOM INTERFACE CABLES
The apparatus manufacturer will supply and install two (2) radio interface cables before delivery
of the vehicle.
The radio equipment to be used by the customer will be:
Kenwood , Model TK790
Motorola High Power , Model Astro digital spectra plus W9
0620831 SP Headset, Sigtronics, SE-48-GEL
Over The Head, Flex Mic, Standard
HEADSET, OVER THE HEAD
There will be four (4) Sigtronics, Model SE-48-GEL, over the head, standard headset(s) provided
driver, officer, and 2 crew cab positions.
Each headset will feature:
Coiled cord with single nickel coated plug
Noise cancelling electret microphone with wind muff
Flexible microphone boom rotates 180 degrees for left or right dress
Gel earseals
Volume control
24 dB noise reduction
0681408 Hangers For Headsets, NFPA, Each
HEADSET HANGERS
There will be four (4) headset hanger(s) installed driver's seat, officer's seat, driver's side inboard
forward facing seat and passenger's side inboard forward facing seat. The hanger(s) will meet
NFPA 1901, Section 14.1.11, requirement for equipment mounting.
0616382 Install Customer Provided
GPS/Multimode Antenna(s)
GPS / MULTIMODE ANTENNA INSTALLATION
There will be one (1) customer supplied GPS / Multimode antenna(s) with stud mount for thick
roof material to be installed on the roof. The antenna coax cable(s) will be run per the packing list
/ instructions provided to the third party installer.
Specific shipping requirements will be followed. The GPS / Multimode antenna will be sent to the
apparatus manufacturers preferred installer prior to cab fabrication.
29377Bid #:
PROPOSAL NO. 81217-180670250 Install Customer Provided Two-Way
Radio(s), Enforcer Chassis
TWO WAY RADIO INSTALLATION
There will be two (2) customer supplied two way radio(s) sent to the apparatus manufacturers
preferred radio installer to be installed per the shipping document. No antenna mount or whip will
be included in this option.
Specific radio shipping requirements will be followed.
0597940 Install Customer Provided Two-Way
Radio Speaker(s)
TWO WAY RADIO SPEAKER INSTALLATION
There will be two (2) customer supplied two way radio speakers sent to the apparatus
manufacturers preferred third party installer to be installed location TBD as this is a new chassis
for the customer.
Specific shipping requirements will be followed.
0687904 Antenna Mount, Custom Chassis,
Cable Routed to Behind Officer Seat
RADIO ANTENNA MOUNT
There will be one (1) standard 1.125", 18 thread antenna-mounting base(s) installed behind
lightbar on DS. VHF antenna behind driver seat. Stub at least 18" inboard from sides of cab on
the cab roof with high efficiency, low loss, coaxial cable(s) routed within the cab / crew area to
base #1 antenna cable to run down DS of cab on the cab roof with high efficiency, low loss,
coaxial cable(s) routed to behind the officer seat. A weatherproof cap will be installed on the
mount.
0694166 Antenna Mount, Larsen
NMOKHFUDTHK, 0-6000MHz
RADIO ANTENNA MOUNT
There will be one (1) Larson, model NMOKHFUDTHK, 0-6000MHz NMO style antenna mounting
base(s) with weatherproof cap(s) and 17 feet of RG58A/U dual shield coax located on the cab
roof DS . The cable(s) will be routed Stub at least 18" inboard from side of cab on the cab roof
with RG58A/U dual shield coax routed within the cab / crew area to base #2 antenna cable to run
down PS of cab and terminate behind the power dist panel access door front of officer seat.
0653519 Camera, Pierce, Driver Mux, R, RS,
LS Cameras
VEHICLE CAMERA SYSTEM
There will be a color vehicle camera system provided with the following:
One (1) camera located at the rear of the apparatus, pointing rearward, displayed automatically
with the vehicle in reverse.
One (1) camera located on the right side of the apparatus, pointing rearward, displayed
automatically with the right side turn signal.
One (1) camera located on the left side of the apparatus, pointing rearward, displayed
automatically with the left side turn signal.
The camera images will be displayed on the driver's vehicle information center display. Audio
from the microphone on the rear camera will be emitted by an amplified speaker with volume
control located behind the driver seat.
The following components will be included:
One (1) SV-CW134639CAI Camera
Two (2) CS134404CI Side cameras
One (1) Amplified speaker (if applicable)
All necessary cables
0511071 Guard, 4-Way, Rear Vision Camera
VEHICLE CAMERA GUARD
There will be one (1) aluminum treadplate guard(s) fastened over the vehicle camera(s) located
at the rear of the body .
0615111 Pierce Command Zone, Advanced
Electronics & Control System, Diag
LEDs, Enf, WiFi
ELECTRICAL POWER CONTROL SYSTEM
The primary power distribution will be located forward of the officer's seating position and be
easily accessible while standing on the ground for simplified maintenance and troubleshooting.
Additional electrical distribution centers will be provided throughout the vehicle to house the
vehicle's electrical power, circuit protection, and control components. The electrical distribution
centers will be located strategically throughout the vehicle to minimize wire length. For ease of
maintenance, all electrical distribution centers will be easily accessible. All distribution centers
containing fuses, circuit breakers and/or relays will be easily accessible.
Distribution centers located throughout the vehicle will contain battery powered studs for
supplying customer installed equipment thus providing a lower cost of ownership.
Circuit protection devices, which conform to SAE standards, will be utilized to protect electrical
circuits. All circuit protection devices will be rated per NFPA requirements to prevent wire and
component damage when subjected to extreme current overload. General protection circuit
breakers will be Type-I automatic reset (continuously resetting). When required, automotive type
fuses will be utilized to protect electronic equipment. Control relays and solenoid will have a direct
30377Bid #:
PROPOSAL NO. 81217-18current rating of 125 percent of the maximum current for which the circuit is protected per NFPA.
SOLID-STATE CONTROL SYSTEM
A solid-state electronics based control system will be utilized to achieve advanced operation and
control of the vehicle components. A fully computerized vehicle network will consist of electronic
modules located near their point of use to reduce harness lengths and improve reliability. The
control system will comply with SAE J1939-11 recommended practices.
The control system will operate as a master-slave system whereas the main control module
instructs all other system components. The system will contain patented Mission Critical software
that maintains critical vehicle operations in the unlikely event of a main controller error. The
system will utilize a Real Time Operating System (RTOS) fully compliant with OSEK/VDX™
specifications providing a lower cost of ownership.
For increased reliability and simplified use the control system modules will include the following
attributes:
Green LED indicator light for module power
Red LED indicator light for network communication stability status
Control system self test at activation and continually throughout vehicle operation
No moving parts due to transistor logic
Software logic control for NFPA mandated safety interlocks and indicators
Integrated electrical system load management without additional components
Integrated electrical load sequencing system without additional components
Customized control software to the vehicle's configuration
Factory and field re programmable to accommodate changes to the vehicle's operating
parameters
Complete operating and troubleshooting manuals
USB connection to the main control module for advanced troubleshooting
To assure long life and operation in a broad range of environmental conditions, the solid-state
control system modules will meet the following specifications:
Module circuit board will meet SAE J771 specifications
Operating temperature from -40C to +70C
Storage temperature from -40C to +70C
Vibration to 50g
IP67 rated enclosure (Totally protected against dust and also protected against the effect of
temporary immersion between 15 centimeters and one (1) meter)
Operating voltage from eight (8) volts to 16 volts DC
The main controller will activate status indicators and audible alarms designed to provide warning
of problems before they become critical.
CIRCUIT PROTECTION AND CONTROL DIAGRAM
Copies of all job-specific, computer network input and output (I/O) connections will be provided
with each chassis. The sheets will indicate the function of each module connection point, circuit
protection information (where applicable), wire numbers, wire colors and load management
information.
ON-BOARD ADVANCED/VISUAL ELECTRICAL SYSTEM DIAGNOSTICS
The on-board information center will include the following diagnostic information:
Text description of active warning or caution alarms
Simplified warning indicators
Amber caution indication with intermittent alarm
Red warning indication with steady tone alarm
All control system modules, with the exception of the main control module, will contain on-board
visual diagnostic LEDs that assist in troubleshooting. The LEDs will be enclosed within the
sealed, transparent module housing near the face of the module. One LED for each input or
output will be provided and will illuminate whenever the respective input or output is active. Color-
coded labels within the modules will encompass the LEDs for ease of identification. The LED
indicator lights will provide point of use information for reduced troubleshooting time without the
need for an additional computer.
TECH MODULE WITH WIFI
An in cab module will provide WiFi wireless interface and data logging capability. The WiFi
interface will comply with IEEE 802.11 b/g/n capabilities while communicating at 2.4 Gigahertz.
The module will provide an external antenna connection allowing a line of site communication
range of up to 300 feet with a roof mounted antenna.
The module will transmit a password protected web page to a WiFi enabled device (i.e. most
smart phones, tablets or laptops) allowing two levels of user interaction. The firefighter level will
allow vehicle monitoring of the vehicle and firefighting systems on the apparatus. The technician
level will allow diagnostic access to inputs and outputs installed on the Command Zone, control
and information system.
The data logging capability will record faults from the engine, transmission, ABS and Command
Zone, control and information systems as they occur. No other data will be recorded at the time
the fault occurs. The data logger will provide up to 2 Gigabytes of data storage.
A USB connection will be provided on the Tech Module. It will provide a means to download data
logger information and update software in the device.
PROGNOSTICS
A software based vehicle tool will be provided to predict remaining life of the vehicles critical fluid
and events.
The system will send automatic indications to the Command Zone, color display and/or wireless
enabled device to proactively alert of upcoming service intervals.
Prognostics will include:
Engine oil and filter
Transmission oil and filter
Pump oil (if equipped)
Foam oil (if equipped)
Aerial oil and filter (if equipped)
ADVANCED DIAGNOSTICS
An advanced, Windows-based, diagnostic software program will be provided for this control
system. The software will provide troubleshooting tools to service technicians equipped with a
Windows-based computer or wireless enabled device.
The service and maintenance software will be easy to understand and use and have the ability to
view system input/output (I/O) information.
INDICATOR LIGHT AND ALARM PROVE-OUT SYSTEM
31377Bid #:
PROPOSAL NO. 81217-18A system will be provided which automatically tests basic indicator lights and alarms located on
the cab instrument panel.
VOLTAGE MONITOR SYSTEM
A voltage monitoring system will be provided to indicate the status of the battery system
connected to the vehicle's electrical load. The system will provide visual and audible warning
when the system voltage is below or above optimum levels.
The alarm will activate if the system falls below 11.8 volts DC for more than two (2) minutes.
POWER AND GROUND STUDS
Spare circuits will be provided in the primary distribution center for two-way radio equipment.
The spare circuits will consist of the following:
One (1) 12-volt DC, 30 amp battery direct spare
One (1) 12-volt DC ground and un-fused switched battery stud located in or adjacent to the power
distribution center
ENHANCED SOFTWARE
The solid-state control system will include the following software enhancements:
All perimeter lights and scene lights (where applicable) will be deactivated when the parking
brake is released.
Cab and crew cab dome lights will remain on for ten (10) seconds for improved visibility after the
doors close. The dome lights will dim after ten (10) seconds or immediately if the vehicle is put
into gear.
Cab and crew cab perimeter lights will remain on for ten (10) seconds for improved visibility after
the doors close. The dome lights will dim after ten (10) seconds or immediately if the vehicle is
put into gear.
EMI/RFI PROTECTION
To prevent erroneous signals from crosstalk contamination and interference, the electrical system
will meet, at a minimum, SAE J551/2, thus reducing undesired electromagnetic and radio
frequency emissions. An advanced electrical system will be used to ensure radiated and
conducted electromagnetic interference (EMI) or radio frequency interference (RFI) emissions are
suppressed at their source.
The apparatus will have the ability to operate in the electromagnetic environment typically found
in fire ground operations to ensure clean operations. The electrical system will meet, without
exceptions, electromagnetic susceptibility conforming to SAE J1113/25 Region 1, Class C EMR
for 10KHz-1GHz to 100 Volts/Meter. The vehicle OEM, upon request, will provide EMC testing
reports from testing conducted on an entire apparatus and will certify that the vehicle meets SAE
J551/2 and SAE J1113/25 Region 1, Class C EMR for 10KHz-1GHz to 100 Volts/Meter
requirements.
EMI/RFI susceptibility will be controlled by applying appropriate circuit designs and shielding. The
electrical system will be designed for full compatibility with low-level control signals and high-
powered two-way radio communication systems. Harness and cable routing will be given careful
attention to minimize the potential for conducting and radiated EMI/RFI susceptibility.
0624253 Electrical System, Enforcer MUX
ELECTRICAL
All 12-volt electrical equipment installed by the apparatus manufacturer will conform to modern
automotive practices. All wiring will be high temperature crosslink type. Wiring will be run, in loom
or conduit, where exposed and have grommets where wire passes through sheet metal.
Automatic reset circuit breakers will be provided which conform to SAE Standards. Wiring will be
color, function and number coded. Function and number codes will be continuously imprinted on
all wiring harness conductors at 2.00" intervals. Exterior exposed wire connectors will be positive
locking, and environmentally sealed to withstand elements such as temperature extremes,
moisture and automotive fluids.
Electrical wiring and equipment will be installed utilizing the following guidelines:
All holes made in the roof will be caulked with silicon. Large fender washers, liberally caulked, will
be used when fastening equipment to the underside of the cab roof.
Any electrical component that is installed in an exposed area will be mounted in a manner that
will not allow moisture to accumulate in it. Exposed area will be defined as any location outside of
the cab or body.
Electrical components designed to be removed for maintenance will not be fastened with nuts
and bolts. Metal screws will be used in mounting these devices. Also a coil of wire will be
provided behind the appliance to allow them to be pulled away from mounting area for inspection
and service work.
Corrosion preventative compound will be applied to all terminal plugs located outside of the cab
or body. All non-waterproof connections will require this compound in the plug to prevent
corrosion and for easy separation (of the plug).
All lights that have their sockets in a weather exposed area will have corrosion preventative
compound added to the socket terminal area.
All electrical terminals in exposed areas will have silicon (1890) applied completely over the metal
portion of the terminal.
All lights and reflectors, required to comply with Federal Motor Vehicle Safety Standard #108, will
be furnished. Rear identification lights will be recessed mounted for protection. Lights and wiring
mounted in the rear bulkheads will be protected from damage by installing a false bulkhead inside
the rear compartments.
An operational test will be conducted to ensure that any equipment that is permanently attached
to the electrical system is properly connected and in working order.
The results of the tests will be recorded and provided to the purchaser at time of delivery.
32377Bid #:
PROPOSAL NO. 81217-180098841 Batteries, (6) Deka Grp 31, 1000
CCA each, Threaded Stud
BATTERY SYSTEM
Six (6) 12 volt, Deka, Model 1231MF, maintenance free group 31 batteries that include the
following features, each, will be provided:
1000 CCA (cold cranking amps)
185 reserve capacity
High cycle
Ref. CA of 1190 at 0 degrees Fahrenheit
185 reserve capacity
Threaded studs
0008621 Battery System, Single Start, All
Custom Chassis
BATTERY SYSTEM
There will be a single starting system with an ignition switch and starter button provided and
located on the cab instrument panel.
MASTER BATTERY SWITCH
There will be a master battery switch provided within the cab within easy reach of the driver to
activate the battery system.
An indicator light will be provided on the instrument panel to notify the driver of the status of the
battery system.
0002698 Battery Compartment,
Saber/Enforcer
BATTERY COMPARTMENTS
Batteries will be placed on non-corrosive mats and stored in well ventilated compartments located
under the cab.
Heavy-duty, 2/0 gauge, color coded battery cables will be provided. Battery terminal connections
will be coated with anti-corrosion compound.
Battery solenoid terminal connections will be encapsulated with semi-permanent rubberized
compound.
JUMPER STUDS
One (1) set of battery jumper studs with plastic color-coded covers will be included on the battery
compartments.
0531315 Charger, Sngl Sys, IOTA, DSL-75, 75
Amp, Kussmaul 091-94-12 Ind,
Qtm/Enf/SFR
BATTERY CHARGER
There will be an IOTA™, Model DSL 75, battery charger with IQ4, controller provided.
The battery charger will be wired to the AC shoreline inlet through an AC receptacle adjacent to
this battery charger.
There will be a Kussmaul™, Model #091-94-12, remote indicator included.
0779452 Location, Charger, Cab EMS Compt,
Back Wall
The battery charger will be located on the back wall of the EMS compartment, located same as
previous job #30272.
0530949 Location, Bat Chrg Ind, Driver's Seat
Riser
The battery charger indicator will be located on the driver's seat riser.
0016838 Shoreline, 30A 120V, Twist lock,
NEMA L5-30
SHORELINE
There will be one (1) 30 amp 120 volt AC twist lock inlet(s) NEMA L5-30 with gray cover(s)
provided to operate the dedicated 120 volt AC circuits on the apparatus.
The shoreline(s) will be connected to battery charger.
A mating connector body will also be supplied with the loose equipment.
There will be a label installed near the inlet(s) that state the following:
Line Voltage
Current Ratting (amps)
Phase
Frequency
0026800 Shoreline Location
The shoreline receptacle will be located in the driver side lower step well of cab.
0784718 SP Solar Panel, Sunforce, Crystalline (2)
w/Digital Charge Controller, Cab Roof
BATTERY CHARGING SOLAR PANEL
There will be two (2) Sunforce Crystalline, Model 37150, solar panel(s) provided on the cab roof
On the crew cab roof positioned as needed to fit the roof. to help charge the batteries.
There will be one (1) Sunforce, Model 60032, 12 volt 30 amp digital charge controller provided on
the side of the driver's seat with a bracket which can detect either battery voltage or charging
current.
There will be a disconnect switch disconnect switch to be next to the driver side cab seat riser on
a bracket with the controller. Refer to pictured in the job E folder for a similar installation. provided
to activate the charging to the batteries.
The controller will have the following features:
Battery Voltage Tester
Battery Type Selector
Safety Circuit Protection
Discharge Protection
Thermal Protection
33377Bid #:
PROPOSAL NO. 81217-180647729 Alternator, 320 amp, Delco Remy
40SI
ALTERNATOR
A Delco Remy®, Model 40SI, alternator will be provided. It will have a rated output current of 320
amps, as measured by SAE method J56. The alternator will feature an integral regulator and
rectifier system that has been tested and qualified to an ambient temperature of 257 degrees
Fahrenheit (125 degrees Celsius). The alternator will be connected to the power and ground
distribution system with heavy-duty cables sized to carry the full rated alternator output.
0645619 Charger Socket, Blue Sea 1016 Dual
USB Type A
DUAL USB SOCKET
There will be four (4) Blue Sea, Model 1016, dual USB type A charger sockets installed one (1) in
center console next to power point, one (1) on officer's dash next to power point, and one (1)
each side EMS cabinet (outboard wall) in a separate box with power point. . The socket will be
powered directly to the battery power .
0092582 Load Manager/Sequencer, MUX
ELECTRONIC LOAD MANAGER
An electronic load management (ELM) system will be provided that monitors the vehicles 12-volt
electrical system, automatically reducing the electrical load in the event of a low voltage condition,
and automatically restoring the shed electrical loads when a low voltage condition expires. This
ensures the integrity of the electrical system.
For improved reliability and ease of use, the load manager system will be an integral part of the
vehicle's solid state control system requiring no additional components to perform load
management tasks. Load management systems which require additional components will not be
allowed.
The system will include the following features:
System voltage monitoring.
A shed load will remain inactive for a minimum of five minutes to prevent the load from cycling on
and off.
Sixteen available electronic load shedding levels.
Priority levels can be set for individual outputs.
High Idle to activate before any electric loads are shed and deactivate with the service brake.
If enabled:
"Load Man Hi-Idle On" will display on the information center.
Hi-Idle will not activate until 30 seconds after engine start up.
Individual switch "on" indicator to flash when the particular load has been shed.
The information center indicates system voltage.
The information center, where applicable, includes a "Load Manager" screen indicating the
following:
Load managed items list, with priority levels and item condition.
Individual load managed item condition:
ON = not shed
SHED = shed
SEQUENCER
A sequencer will be provided that automatically activates and deactivates vehicle loads in a
preset sequence thereby protecting the alternator from power surges. This sequencer operation
will allow a gradual increase or decrease in alternator output, rather than loading or dumping the
entire 12 volt load to prolong the life of the alternator.
For improved reliability and ease of use, the load sequencing system will be an integral part of
the vehicle's solid state control system requiring no additional components to perform load
sequencing tasks. Load sequencing systems which require additional components will not be
allowed.
Emergency light sequencing will operate in conjunction with the emergency master light switch.
When the emergency master switch is activated, the emergency lights will be activated one by
one at half-second intervals. Sequenced emergency light switch indicators will flash while waiting
for activation.
When the emergency master switch is deactivated, the sequencer will deactivate the warning
light loads in the reverse order.
Sequencing of the following items will also occur, in conjunction with the ignition switch, at half-
second intervals:
Cab Heater and Air Conditioning
Crew Cab Heater (if applicable)
Crew Cab Air Conditioning (if applicable)
Exhaust Fans (if applicable)
Third Evaporator (if applicable)
34377Bid #:
PROPOSAL NO. 81217-180780484 Headlights, Rect LED, HiViz FT-4X6-
4KIT, AXT/DCF/Enf/Imp/Sab/Vel
HEADLIGHTS
There will be a HiViz part number FT-4X6-4KIT, that includes four (4) 4.00" high x 6.00" long
rectangular LED lights with parking lamp illumination around the outside of the lamps mounted in
the front quad style, chrome housing on each side of the cab grille:
the outside lamp on each side will contain a part number FT-4X6-HL with low beam LEDs
the inside lamp on each side will contain a part number FT-4X6-H with high beam LEDs
the lights will be controlled through the headlight switch
0648426 Light, Directional, Wln 60A00TAR
Arrow, Common Bzl, Above
Headlts,Sab/Enf
DIRECTIONAL LIGHTS
There will be two (2) Whelen, Model 60A00T*R, amber LED populated arrow directional lights
provided on the front of the cab, above the headlights. Each light will be housed in the same quad
common bezel as the front warning light. The lens color(s) to be the same as the LEDs.
0620054 Light, Directional/Marker,
Intermediate, Weldon 9186-8580-29
LED 2lts
INTERMEDIATE LIGHT
There will be two (2) Weldon, Model 9186-8580-29, amber LED turn signal marker lights
furnished, one (1) each side, in the rear fender panel. The light will double as a turn signal and
marker light.
0782103 Lights, Clearance/Marker/ID, Front,
Included with Visor Scene Light
CAB CLEARANCE/MARKER/ID LIGHTS
The front identification and clearance lights will be included in the front visor scene light.
0647899 Lights, Directional/Marker, Cab Front
Side, Weldon 9186-8580-29 LED,
Sab/Enf
FRONT CAB SIDE DIRECTIONAL/MARKER LIGHTS
There will be two (2) Weldon, Model 9186-8580-29, amber LED lights installed front of the cab
door, one (1) on each side of the cab.
The lights will activate as marker lights with the headlight switch and directional lights with the
corresponding directional circuit.
0627282 Lights, Clearance/Marker/ID, Rear,
FRP LED Bar & P25 LED 4Lts
REAR CLEARANCE/MARKER/ID LIGHTING
There will be a three (3) LED light bar used as identification lights located at the rear of the
apparatus per the following:
As close as practical to the vertical centerline
Centers spaced not less than 6.00" or more than 12.00" apart
Red in color
All at the same height
There will be two (2) LED lights installed at the rear of the apparatus used as clearance lights
located at the rear of the apparatus per the following:
To indicate the overall width of the vehicle
One (1) each side of the vertical centerline
As near the top as practical
Red in color
To be visible from the rear
All at the same height
There will be two (2) LED lights installed on the side of the apparatus used as marker lights as
close to the rear as practical per the following:
To indicate the overall length of the vehicle
One (1) each side of the vertical centerline
As near the top as practical
Red in color
To be visible from the side
All at the same height
There will be two (2) red reflectors located on the rear of the truck facing to the rear. One (1) each
side, as far to the outside as practical, at a minimum of 15.00", but no more than 60.00", above
the ground.
There will be two (2) red reflectors located on the side of the truck facing to the side. One (1)
each side, as far to the rear as practical, at a minimum of 15.00", but no more than 60.00", above
the ground.
Per FMVSS 108 and CMVSS 108 requirements.
0564683 Lights, Tail, Wln M6BTT* Red LED
Stop/Tail & M6T* Amber LED Dir Arw
For Hsg
REAR FMVSS LIGHTING
The rear stop/tail and directional LED lighting will consist of the following:
Two (2) Whelen®, Model M6BTT, red LED stop/tail lights
Two (2) Whelen, Model M6T, amber LED arrow turn lights
The lights shall be provided with color lenses.
The lights will be mounted in a polished combination housing.
0561471 Lights, Backup, Wln M6BUW, LED,
For Tail Lt Housing
There will be two (2) Whelen Model M6BUW, LED backup lights provided in the tail light housing.
0664481 Bracket, License Plate & Light, P25
LED
LICENSE PLATE BRACKET
There will be one (1) license plate bracket mounted on the rear of the body.
A white LED light will illuminate the license plate. A polished stainless steel light shield will be
provided over the light that will direct illumination downward, preventing white light to the rear.
35377Bid #:
PROPOSAL NO. 81217-180556842 Bezels, Wln, (2) M6 Chrome Pierce,
For mtg (4) Wln M6 lights
LIGHTING BEZEL
There will be two (2) Whelen, Model M6FCV4P, four (4) place chromed ABS housings with Pierce
logos provided for the rear M6 series stop/tail, directional, back up, scene lights or warning lights.
0589905 Alarm, Back-up Warning, PRECO
1040
BACK-UP ALARM
A PRECO, Model 1040, solid-state electronic audible back-up alarm that actuates when the truck
is shifted into reverse will be provided. The device will sound at 60 pulses per minute and
automatically adjust its volume to maintain a minimum ten (10) dBA above surrounding
environmental noise levels.
0626588 Lights, Perimeter Cab, TecNiq T10-
LC00-1 15" LED 4Dr
CAB PERIMETER SCENE LIGHTS
There will be four (4) TecNiq, Model T10-LC00-1, 15.00" lights with white LEDs and 45 degree
stainless steel brackets provided per the following:
one (1) under the driver's side cab access step
one (1) under the passenger's side cab access step
one (1) under the passenger's side crew cab access step
one (1) under the driver's side crew cab access step
The lights will be activated when the battery switch is on, when the respective door is open and
by the same control selected for the body perimeter lights.
0617901 Lights, Perimeter Pump House,
TecNiq T10-LC00-1 15" LED 2lts
PUMP HOUSE PERIMETER LIGHTS
There will be two (2) TecNiq, Model T10-LC00-1, 15.00" white 12 volt DC LED weatherproof strip
lights provided under the pump panel running boards, one (1) each side.
The lights will be controlled by the same means as the body perimeter lights.
0626579 Lights, Perimeter Body, TecNiq T10-
LC00-1 15" LED 2lts, Rear Step
BODY PERIMETER SCENE LIGHTS
There will be two (2) TecNiq, Model T10-LC00-1, 15.00" 12 volt DC LED strip lights provided at
the rear step area of the body, one (1) each side shining to the rear.
The perimeter scene lights will be activated when a switch within reach of the driver is activated.
0566799 Lights, Step, P25 LED 4lts, Ign,
Parking Brake Activated
STEP LIGHTS
There will be four (4) white LED, step lights provided. One (1) step light will be provided on each
side, on the front compartment face and two (2) step lights at the rear to illuminate the tailboard.
In order to ensure exceptional illumination, each light will provide a minimum of 25 foot-candles
(fc) covering an entire 15" x 15" square placed ten (10) inches below the light and a minimum of
1.5 fc covering an entire 30" x 30" square at the same ten (10) inch distance below the light.
These step lights will be actuated when the ignition switch is on and the parking brake is set.
All other steps on the apparatus will be illuminated per the current edition of NFPA 1901.
0781453 Lights, Side Scene, HiViz FT-GESM
LED 2nd
SIDE SCENE LIGHTS
There will be one (1) HiViz, Model FT-GESM, 10,491 effective lumens 8.65" high x 10.61" wide x
2.75" deep light(s) with white LEDs installed on the side of the apparatus, one (1) over the
passengerer's side EMS access door.
The light(s) will be activated by a switch at the driver's side switch panel.
The light(s) may be load managed when the parking brake is applied.
0781457 Lights, Side Scene, HiViz FT-GESM
LED 1st
SIDE SCENE LIGHTS
There will be one (1) HiViz, Model FT-GESM, 10,491 effective lumens 8.65" high x 10.61" wide x
2.75" deep light(s) with white LEDs installed on the side of the apparatus, one (1) over the driver's
side EMS access door.
The light(s) will be activated by a switch at the driver's side switch panel.
The light(s) may be load managed when the parking brake is applied.
0776169 SP Lights, Rear Scene, HiViz FT-GESM
LED 1st
REAR SCENE LIGHTS
There will be two (2) HiViz, Model FT-GESM, 10,491 effective lumens 8.65" high x 10.61" wide x
2.75" deep light(s) with white LEDs installed on the side of the apparatus, one (1) each side high
on rear body bulkhead.
The light(s) will be activated by a switch at the driver's side switch panel and by a switch in a
stainless steel cup located on the driver's side at the rear of the apparatus no more than 62.00"
from the ground.
The light(s) may be load managed when the parking brake is applied.
0532358 Not Required, Deck Lights, Other
Hose Bed & Rear Lighting
36377Bid #:
PROPOSAL NO. 81217-180645877 Lights, Hose Bed, Sides, Dual LED
Light Strips
HOSE BED LIGHTS
There will be white 12 volt DC LED light strips with stainless steel protective cover, provided to
light the hose bed area. Hose Bed lights will meet the photometric levels listed in NFPA 1901 for
Hose Bed lighting requirements.
Light strip(s) will be installed along the upper edge of the left side of the hose bed.
Light strip(s) will be installed along the upper edge of the right side of the hose bed.
The lights will be activated when the hosebed cover is raised.
0645677 Lights, Not Required, Rear Work, Alt.
12 Volt Lights At Rear Body
0790943 SP Light, HiViz FT-SL-15-*-*, FRC Pole
Mt, 2nd
12 VOLT LIGHTING
There will be one (1) HiViz Model FT-SL-15-*-*, 11,100 effective lumens 12 volt DC LED light(s)
installed on the apparatus with Fire Research extendable pole(s).
The painted parts of the light housing and brackets to be white.
The light will be configured with a combination of flood and spot optics.
The lights will be installed PS behind cab.
The pole(s) will be side mount push up pole(s) with a steady rest cup bracket and not stowed
switch connected to the Do Not Move Truck Indicator circuit.
The lights will be controlled by a switch at the driver's side switch panel.
These light(s) may be load managed when the parking brake is applied.
0790946 SP Light, HiViz FT-SL-15-*-*, FRC Pole
Mt, 1st
12 VOLT LIGHTING
There will be one (1) HiViz Model FT-SL-15-*-*, 11,100 effective lumens 12 volt DC LED light(s)
installed on the apparatus with Fire Research extendable pole(s).
The painted parts of the light housing and brackets to be white.
The light will be configured with a combination of flood and spot optics.
The lights will be installed DS behind cab.
The pole(s) will be side mount push up pole(s) with a steady rest cup bracket and not stowed
switch connected to the Do Not Move Truck Indicator circuit.
The lights will be controlled by a switch at the driver's side switch panel.
These light(s) may be load managed when the parking brake is applied.
0763922 SP Light, Visor, HiViz LED, FT-B-72-ML-
*, Wire Covers, Cnt Feature MUX
12 VOLT LIGHTING
There will be a HiViz Model FT-B-72-ML-*, 2.56" high x 72.69" long x 2.45" deep 21,407 effective
lumens 12 volt DC light on brackets in front of the cab roof per the following:
54 white scene LEDs configured in spot and flood optics
three (3) amber LED identification lights
two (2) amber LED clearance lights
The painted parts of the light housing and brackets to be white.
The light will be activated by a switch at the driver's side switch panel.
The scene LEDs may be load managed when the parking brake is applied.
There will be wire covers installed to protect the wires on the light.
0787447 Lights, Walk Surf, Dual LED Light
Strips, Cargo Area, Bdy Stp Lt
WALKING SURFACE LIGHTS
There will be white 12 volt DC LED light strips with stainless steel protective cover, provided to
light the cargo area.
One (1) light strip will be installed the entire length of the driver's side of the cargo area.
One (1) light strip will be installed the entire length of the passenger's side of the cargo area.
The light will be activated when the body step lights are on.
0060100 Pumper, Short, Galvanneal, 2nd Gen
0554271 Body Skirt Height, 20"
37377Bid #:
PROPOSAL NO. 81217-180028294 Tank, Water, 500 Gallon, Poly, Short WATER TANK
Booster tank will have a capacity of 500 gallons and be constructed of polypropylene plastic by
United Plastic Fabricating, Incorporated.
Tank joints and seams will be nitrogen welded inside and out.
Tank will be baffled in accordance with NFPA bulletin 1901 requirements.
Baffles will have vent openings at both the top and bottom to permit movement of air and water
between compartments.
Longitudinal partitions will be constructed of .38" polypropylene plastic and will extend from the
bottom of the tank through the top cover to allow for positive welding.
Transverse partitions will extend from 4.00" off the bottom of the tank to the underside of the top
cover.
All partitions will interlock and will be welded to the tank bottom and sides.
Tank top will be constructed of .50" polypropylene. It will be recessed .38" and will be welded to
the tank sides and the longitudinal partitions.
Tank top will be sufficiently supported to keep it rigid during fast filling conditions.
Construction will include 2.00" polypropylene dowels spaced no more than 30.00" apart and
welded to the transverse partitions. Two (2) of the dowels will be drilled and tapped (.50"
diameter, 13.00" deep) to accommodate lifting eyes.
A sump that will be sized dependent on the tank to pump plumbing will be provided at the bottom
of the water tank.
Sump will include a drain plug and the tank outlet.
Tank will be installed in a fabricated cradle assembly constructed of structural steel.
Sufficient crossmembers will be provided to properly support bottom of tank. Crossmembers will
be constructed of steel bar channel or rectangular tubing.
Tank will "float" in cradle to avoid torsional stress caused by chassis frame flexing. Rubber
cushions, .50" thick x 3.00" wide, will be placed on all horizontal surfaces that the tank rests on.
Stops or other provision will be provided to prevent an empty tank from bouncing excessively
while moving vehicle.
Mounting system will be approved by the tank manufacturer.
0003405 Overflow, 4.00" Water Tank, Poly
Fill tower will be constructed of .50" polypropylene and will be a minimum of 8.00" wide x 14.00"
long.
Fill tower will be furnished with a .25" thick polypropylene screen and a hinged cover.
An overflow pipe, constructed of 4.00" schedule 40 polypropylene, will be installed approximately
halfway down the fill tower and extend through the water tank and exit to the rear of the rear axle.
0028104 Foam Cell Required
0633066 Sleeve through Tank
One (1) sleeve will be provided in the water tank for a 3.00" pipe to the rear.
0553729 Not Required, Restraint, Water Tank,
Heavy Duty
0003429 Not Required, Direct Tank Fill
0003424 Not Required, Dump Valve
0048710 Not Required, Jet Assist
0030007 Not Required, Dump Valve Chute
0514778 Not Required, Switch, Tank Dump
Master
0126632 Hose Bed, Galv, Pumper HOSE BED
The hose bed will be fabricated of 12-gauge galvanneal steel.
The sides will not form any portion of the fender compartments.
Standard hose bed width will be minimum of 68.00" inside.
Upper and rear edges of side panels will have a double break for rigidity.
The upper inside area of the beavertails will be covered with brushed stainless steel to prevent
damage to painted surface when hose is removed.
Flooring of the hose bed will be removable aluminum grating with the top surface corrugated to
aid in hose aeration. The grating slats will be a minimum of 0.50" x 4.50" with spacing between
slats for hose ventilation.
0003481 Hose Bed Capacity, Special
Hose bed will accommodate From DS to PS: 1000' x 4.00" / 10.00"W I.D. / 8.00"W I.D. / 800' x
2.50" (deadlay) / 250' x 2.50".
38377Bid #:
PROPOSAL NO. 81217-180083488 Divider, Hose Bed, .25" Unpainted
HOSE BED DIVIDER
Four (4) adjustable hosebed dividers will be furnished for separating hose.
Each divider will be constructed of a .25" brushed aluminum sheet. Flat surfaces will be sanded
for uniform appearance, or constructed of brushed aluminum.
Divider will be fully adjustable by sliding in tracks, located at the front and rear of the hose bed.
Divider will be held in place by tightening bolts, at each end.
Acorn nuts will be installed on all bolts in the hose bed which have exposed threads.
0526260 Cross-divider, Hose Bed, Location A cross-divider will be provided 98.50"D (rear to front) of hosebed. The divider will be bolted to
the side sheet.
0083511 SP Cover, Front of Hose Bed, Alum
Treadplate
HOSE BED COVER
A full width hose bed cover will be provided above the front upper portion of the body, between
the front body sheet and hose bed cross divider.
The cover will be constructed of .19" bright aluminum treadplate, hinged to the front body sheet
with a full length stainless steel piano hinge and secured at the rear with recessed latches. The
cover will have a 1.25" flange all around with additional bracing to support the weight of a
firefighter.
A hinged cover with recessed latches will be provided for the water tank fill tower access.
Chrome grab handles and gas filled cylinders will be provided to assist in opening and closing of
the cover.
0530804 Cover, Hose Bed, Alum Treadplate
HOSE BED COVER
A two (2) section hose bed cover, constructed of .125" bright aluminum treadplate will be
furnished. The cover will be hinged with full length stainless steel piano hinge. The sides will be
slanted down.
The cover will be reinforced so that it can support the weight of a man walking on the cover.
The cover is designed with the left cover opening first.
If access to the water tank fill tower is blocked by the hose bed cover, then a hinged door will be
provided in it so that the tank may be filled without raising cover doors.
Chrome grab handles and four (4) gas filled cylinders will be provided to assist in opening and
closing the cover. A handrail is to be provided at the rear, in the center of the support, to assist in
opening the cover.
0697328 Flap, Rear of Alum Hose Bed Cover,
Two Piece, Vinyl, w/Seat Belt
Buckles
HOSEBED END FLAP
A pair of black vinyl flaps will be installed on the rear, one for each of the aluminum treadplate
hose bed covers.
Each vinyl flap will have (2) nylon tie down straps, with seat belt buckles.
0695399 Running Boards, 14.75" Deep, Front
and Rear 45 Degree Corners
RUNNING BOARDS
Running boards will be fabricated of .125" bright aluminum treadplate.
Each running board will be supported by a welded 2.00" square tubing and channel assembly,
which will be bolted to the pump compartment substructure.
Running boards will be 14.75" deep and spaced .50" away from the pump panel. The front and
rear outside corner of the running board will be finished with a 45 degree corner where it lines up
with the body.
A splash guard will be provided above the running board treadplate.
0689621 Tailboard, 16" Deep
TAILBOARD
The tailboard will also be constructed of .125" bright aluminum treadplate and spaced .50" from
the body, as well as supported by a structural steel assembly.
The tailboard area will be 16.00" deep.
The exterior side will be flanged down and in for increased rigidity of tailboard structure.
0690037 Wall, Rear, Smooth Aluminum/Body
Material
REAR WALL, SMOOTH ALUMINUM/BODY MATERIAL
The rear facing surfaces of the center rear wall will be smooth aluminum.
The bulkheads, the surface to the rear of the side body compartments, will be smooth and the
same material as the body.
Any inboard facing surfaces below the height of the hosebed will be aluminum diamondplate .
0656196 SP Tow Eyes (2), Painted, Under Body,
Pumper
TOW EYES
Two (2) rear painted tow eyes will be located at the rear of the apparatus mounted to the rear
substructure below the body which is attached directly to the chassis frame rails. The inner and
outer edges of the tow eyes will have a radius.
0590926 Hose Restraint, Running Board,
Velcro Straps
RUNNING BOARD HOSE RESTRAINT
A pair of 2.00" wide black nylon straps with Velcro fasteners will be provided for each hose tray to
secure the hose during travel. There will be One (1) hose tray located in the left side running
board.
39377Bid #:
PROPOSAL NO. 81217-180695615 Tray, Hose, Running Board, Free
Floating, 20' of 5.00" Soft Suction,
Tapered
HOSE TRAY
One (1) hose tray will be made free floating in the driver side running board.
The tray(s) will be flanged and drop in from the top. The ends will be tapered at the front and rear
towards the center. No fasteners will be used to secure the tray(s).
Capacity of the tray will be 20.00' of 5.00" soft suction hose.
Rubber matting will be installed on the floor of the tray to provide proper ventilation.
0003560 Construction, Compt, Galv, Pumper COMPARTMENTATION
Body and compartments will be fabricated of galvanneal steel.
Side compartments will be an integral assembly with the rear fenders.
Circular fender liners will be provided for prevention of rust pockets and ease of maintenance.
Compartment flooring will be 12 gauge and of the sweep out design, with the floor higher than the
compartment door lip.
The compartment door opening will be framed by flanging the edges in 1.75" and bending out
again .75" to form an angle.
Drip protection will be provided above the doors by means of bright aluminum extrusion, formed
bright aluminum treadplate, or polished stainless steel.
The top of the compartment will be covered with bright aluminum treadplate rolled over the edges
on the front, rear, and outward side. These covers will have the corners TIG welded.
Side compartment covers will be separate from the compartment tops.
Front facing compartment walls will be covered with bright aluminum treadplate.
All screws and bolts which protrude into a compartment will have acorn nuts on the ends to
prevent injury.
UNDERBODY SUPPORT SYSTEM
Due to the severe loading requirements of this pumper, a method of body and compartment
support suitable for the intended load will be provided.
The backbone of the support system will be the chassis frame rails, which is the strongest
component of the chassis and designed for sustaining maximum loads.
The support system will include .375" thick steel vertical angle supports bolted to the chassis
frame rails with .625" diameter bolts.
Attached to the bottom of the steel vertical angles will be horizontal angles, with gussets welded
to the vertical members, which extend to the outside edge of the body.
A steel frame will be mounted on the top of these supports to create a floating substructure,
which results in a 500 lb equipment support rating per lower compartment.
The floating substructure will be separated from the horizontal members with neoprene elastomer
isolators. These isolators will reduce the natural flex stress of the chassis from being transmitted
to the body.
The isolators will have a broad load range, proven viability in vehicular applications, be of a fail
safe design and allow for all necessary movement in three (3) transitional and rotational modes.
The neoprene isolators will be installed in a modified V three (3)-point mounting pattern to reduce
the natural flex of the chassis being transmitted to the body.
AGGRESSIVE WALKING SURFACE
All exterior surfaces designated as stepping, standing, and walking areas will comply with the
required average slip resistance of the current NFPA standards.
LOUVERS
Louvers will be stamped into compartment walls to provide the proper airflow inside the body
compartments and to prevent water from dripping into the compartment. Where these louvers
are provided, they will be formed into the metal and not added to the compartment as a separate
plate.
TESTING OF BODY DESIGN
Body structural analysis has been fully tested. Proven engineering and test techniques such as
finite element analysis, model analysis, stress coating and strain gauging have been performed
with special attention given to fatigue, life and structural integrity of the cab, body and
substructure.
The body will be tested while loaded to its greatest in-service weight.
The criteria used during the testing procedure will include:
- Raising opposite corners of the vehicle tires 9.00", simulating the twisting a truck may
experience when driving over a curb.
- Making a 90 degree turn while at 20 mph, simulating aggressive driving conditions.
- Driving the vehicle at 35 mph on a washboard road.
- Driving the vehicle at 55 mph on a smooth road.
- Accelerating the vehicle fully, until reaching the approximate speed of 45 mph, on rough
pavement.
Evidence of actual testing techniques will be made available upon request.
40377Bid #:
PROPOSAL NO. 81217-180557520 LS 145" Rollup, Full Height Front &
Rear, 5" Longer than Std Short Body
LEFT SIDE COMPARTMENTATION
The left side compartmentation will consist of three rollup door compartments.
A full height, rollup door compartment ahead of the rear wheels will be provided. The interior
dimensions of this compartment will be 27.50" wide x 66.63" high x 25.88" deep in the lower
25.00" of the compartment and 12.00" deep in the remaining upper portion. The clear door
opening will be a minimum of 21.75" wide x 56.88" high.
A rollup door compartment over the rear wheels will be provided. The interior dimensions of this
compartment will be 66.50" wide x 32.88" high x 12.00" deep. The clear door opening will be a
minimum of 58.25" wide x 23.13" high.
A full height, rollup door compartment behind the rear wheels will be provided.The interior
dimensions of this compartment will be 47.75" wide x 67.63" high x 12.00" deep. A section
of this compartment will be 25.88" deep for the first 31.50" width x 26.00" height directly
behind the rear wheels. The clear door opening will be a minimum of 44.75" wide x 57.88"
high.
The interior height of the compartments will be measured from the compartment floor to
the ceiling. The spool of the rollup door at the top of the compartment takes up some
usable space. The depth of the compartments will be measured from the back wall to the
inside of the door frame.
Closing of the door will not require releasing, unlocking, or unlatching any mechanism
and will easily be accomplished with one hand.
0652099 RS 145" Rollup 3/4 Height Frt & Rr,
(1) Broom, 5" Longer than Std Short
RIGHT SIDE COMPARTMENTATION
The right side compartmentation will consist of three lap door compartments.
A vertically hinged, single door compartment ahead of the rear wheels will be provided. The
interior dimensions of this compartment will be 27.50" wide x 46.13" high x 25.88" deep in the
lower 25.00" of the compartment and 12.00" deep in the remaining upper portion. The clear door
opening will be a minimum of 21.63" wide x 41.38" high.
A horizontally hinged, drop-down door compartment over the rear wheels will be provided. The
interior dimensions of this compartment will be 66.50" wide x 12.38" high x 12.00" deep. The
clear door opening will be a minimum of 59.25" wide x 6.63" high.
A vertically hinged, double door compartment behind the rear wheels will be provided.The
interior dimensions of this compartment will be 47.75" wide x 47.13" high x 12.00" deep. A
section of this compartment will be 25.88" deep for the first 31.50" width x 26.00" height
directly behind the rear wheels. The clear door opening will be a minimum of 43.50" wide x
42.38" high.
The interior height of the compartments will be measured from the compartment floor to
the ceiling. The depth of the compartments will be measured from the back wall to the
inside of the door frame.
Closing of the doors will not require releasing, unlocking, or unlatching any mechanism
and will easily be accomplished with one hand.
The vertically hinged doors will be furnished with a positive door holder.
The drop-down door will be furnished with two chain-style door holders with a plastic
covering around the chain.
41377Bid #:
PROPOSAL NO. 81217-180692733 Doors, Rollup, Gortite, Side
Compartments
SIDE COMPARTMENT ROLLUP DOOR(S)
There will be five (5) compartment doors installed on the side compartments. The doors will be
double faced aluminum construction, painted one (1) color to match the lower portion of the body
and manufactured by Gortite®.
Lath sections will be an interlocking rib design and will be individually replaceable without
complete disassembly of door.
Between each slat at the pivoting joint will be a PVC inner seal to prevent metal to metal contact
and prevent dirt or moisture from entering the compartments. Seals will allow door to operate in
extreme temperatures ranging from 180 to -40 degrees Fahrenheit. Side, top and bottom seals
will be provided to resist ingress of dirt and weather and be made of Santoprene.
All hinges, barrel clips and end pieces will be nylon 66. All nylon components will withstand
temperatures from 300 to -40 degrees Fahrenheit.
A polished stainless steel lift bar with locking key latches to be provided for each roll-up door. The
keys to be Model 1250 for all compartment doors. Lift bar will be located at the bottom of door
and have latches on the outer extrusion of the doors frame. A ledge will be supplied over lift bar
for additional area to aid in closing the door.
Doors will be constructed from an aluminum box section. The exterior surface of each slat will be
flat. The interior surfaces will be concave to provide strength and prevent loose equipment from
jamming the door from inside.
To conserve space in the compartments, the spring roller assembly will not exceed 3.00" in
diameter.
The header for the rollup door assembly will not exceed 4.00".
A heavy-duty magnetic switch will be used for control of open compartment door warning lights.
0013668 Rear - Double Dr/30.75" FF
COMPARTMENTATION, REAR
A vertically hinged, double door compartment above the rear tailboard will be provided. The
interior dimensions of this compartment will be 40.00" wide x 33.63" high x 25.88" deep. The
clear door opening will be a minimum of 32.00" wide x 28.88" high.
A louvered removable access panel will be furnished on the back wall of the compartment.
The compartment will be open into the rear side compartments.
Closing of the doors will not require releasing, unlocking, or unlatching any mechanism and will
be easily accomplished with one hand. A positive door holder will be furnished with this
compartment.
42377Bid #:
PROPOSAL NO. 81217-180073910 Doors, Lap w/"D" Handles-Rear
Compt
REAR COMPARTMENT DOORS
All hinged compartment doors will be lap style with double panel construction and will be a
minimum of 1.50" thick. To provide additional door strength, a "C" section reinforcement will be
installed between the outer and interior panels.
Doors will be provided with a closed cell rubber gasket around the surface that laps onto the
body. A second heavy-duty automotive rubber molding with a hollow core will be installed on the
door framing that seals onto the interior panel, to ensure a weather resisting compartment..
All compartment doors will have polished stainless steel continuous hinge with a pin diameter of
.25", that is bolted or screwed on with stainless steel fasteners. A strip of dielectric isolation tape
will be provided between the hinge and the door jamb.
All door lock mechanisms will be fully enclosed within the door panels to prevent fouling of the
lock in the event equipment inside shifts into the lock area.
Doors will be latched with recessed, polished stainless steel "D" ring handles and Eberhard 106
locks.
To prevent corrosion caused by dissimilar metals, compartment door handles will not be attached
to outer door panel with screws. A rubber gasket will be provided between the "D" ring handle
and the door.
0554995 No Body Modification Required
0611124 SP Scuffplates Over Rear Fender
Panels, Brushed S/S
SCUFFPLATE ON REAR FENDER PANELS
The rear fender panels, on both sides of the truck, will be covered with brushed stainless steel.
The scuffplate will be fastened to the body panels with stainless steel screws.
0648720 SP Holder, Door, Chain, Vinyl Covered
CHAIN DOOR HOLDERS
two (2) compartment doors will be provided with vinyl covered pull chains. the EMS cabinet doors
on each side of the cab. To restrict the door from opening past 90 degrees.
0616670 Lights, Compt, Pierce LED, Dual
Light Strips, Each Side of Door,
Pumper/Tanker
COMPARTMENT LIGHTING
There will be seven (7) compartment(s) with two (2) white 12 volt DC LED compartment light
strips. The dual light strips will be centered vertically along each side of the door framing. There
will be two (2) light strips per compartment. The dual light strips will be in all body compartment
(s).
Any remaining compartments without light strips will have a 6.00" diameter Truck-Lite, Model:
79384 light. Each light will have a number 1076 one filament, two wire bulb.
Opening the compartment door will automatically turn the compartment lighting on.
0687146 Shelf Tracks, Painted
MOUNTING TRACKS
There will be five (5) sets of tracks for mounting shelf(s) in LS1, LS3, RS1, RS3 and B1. These
tracks will be installed vertically to support the adjustable shelf(s), and will be full height of the
compartment. The tracks will be painted to match the compartment interior.
0622945 Shelves, Adjustable, Full
Width/Depth, Low/Special Side
Height
ADJUSTABLE SHELVES
There will be one (1) shelf provided P3 (upper). The shelf construction will consist of .188"
aluminum painted spatter gray. A capacity rating will not be available on this item due to a
reduced side height being less than 2.00". Each shelf will be infinitely adjustable by means of a
threaded fastener, which slides in a track. Each shelf will as wide and as deep as the
compartment space shall allow.
The shelves will be held in place by .12" thick stamped plated brackets and bolts.
The side height of the shelf/shelves will be as follows:
Front: 1.00" high
Rear: 1.00" high
Left & Right Sides: 1.00" high
0600350 Shelves, Adj, 500 lb Capacity, Full
Width/Depth, Predefined Locations
ADJUSTABLE SHELVES
There will be ten (10) shelves with a capacity of 500 lb provided.
The shelf construction will consist of .188" aluminum painted spatter gray with 2.00" sides.
Each shelf will be infinitely adjustable by means of a threaded fastener, which slides in a track.
The shelves will be held in place by .12" thick stamped plated brackets and bolts.
The location(s) will be in RS1 in the lower third, in RS3 in the lower third, in RS1 in the upper
third, in B1 centered between the floor and ceiling, in LS3 in the upper third, in LS3 in the upper
third, in LS1 in the upper third to the left of the partition, in LS1 in the upper third to the left of the
partition, in LS1 in the lower third to the left of the partition and in LS3 at the depth transition
point.
43377Bid #:
PROPOSAL NO. 81217-180647091 Tray, Floor Mounted, Slide-Out,
500lb, 2.00" Sides
SLIDE-OUT FLOOR MOUNTED TRAY
There will be one (1) floor mounted slide-out tray(s) provided.
Each tray will have 2.00" high sides and a minimum capacity rating of 500 lb in the extended
position.
Each tray will be constructed of aluminum painted spatter gray
There will be two undermount-roller bearing type slides rated at 250lb each provided. The pair of
slides will have a safety factor rating of 2.
To ensure years of dependable service, the slides will be coated with a finish that is tested to
withstand a minimum of 1,000 hours of salt spray per ASTM B117.
To ensure years of easy operation, the slides will require no more than a 50lb force for push-in or
pull-out movement when fully loaded after having been subjected to a 40 hour vibration (shaker)
test under full load. The vibration drive file will have been generated from accelerometer data
collected from a heavy truck chassis driven over rough gravel roads in an unloaded condition.
Proof of compliance will be provided upon request.
Automatic locks will be provided for both the "in" and "out" positions. The trip mechanism for the
locks will be located at the front of the tray for ease of use with a gloved hand.
The location(s) will be B1.
0558501 Drawer Assembly, CTECH, Four
Drawers, Up To 24" Wide
DRAWER ASSEMBLY
A slideout drawer assembly will be installed D3 lower portion.
The clear dimensions starting at the top of the cabinet with the first drawer will be 3.25" with a
face plate that is 4.00" high x 21.00" deep. The clear dimensions of the second drawer will be
3.75" with a face plate that is 4.00" high x 21.00" deep. The clear dimensions of the third drawer
will be 4.75" with a face plate that is 5.00" high x 21.00" deep. The clear dimensions of the fourth
drawer will be 6.75" with a face plate that is 7.00" high x 21.00" deep. Each drawer will be the
same width and not exceed 24.00".
The drawers will have a capacity of 250 pounds.
The drawers will be mounted in a cabinet housing constructed of light gray powder coated
aluminum with anodized aluminum frames. The housing will be 24.00" deep, and completely
enclose the drawer.
A full-length aluminum extruded rail will be provided at the top edge of each drawer. This rail will
act as the latching mechanism as well as the handle for each drawer.
There will be a total of one (1) provided.
0028026 Matting, Turtle Tile, Compt Shelving
only
MATTING, COMPARTMENT SHELVING
Turtle Tile compartment matting will be provided in 11 shelves. The locations are, all eleven (11)
shelves.
The color of the Turtle Tile will be black.
0659383 Matting, Turtle Tile w/Ramp, Compt
Floors
MATTING, COMPARTMENT FLOOR
Turtle Tile compartment matting will be provided in six (6) compartments on the compartment
floor. The locations are, body compartments (D1, D2, R1, P1, P2, and P3).
The Turtle Tile will be black and the leading edge of the matting will include the beveled edge.
The beveled edge will be black .
0003908 Partition, Trans Rear Compt
PARTITION, TRANSVERSE REAR COMPARTMENT
Two (2) partitions will be bolted in place to separate left and right side rear compartments from
the rear tailboard compartment.
0600281 Partition, Vertical Compartment,
Predefined Locations
VERTICAL COMPARTMENT PARTITION
One (1) partition will be provided.
The partition construction will consist of .125" aluminum painted spatter gray. Each partition will
be the full vertical height of the compartment.
The location(s) will be in LS1, 32.00" from the forward door frame.
0004016 Rub Rail, Aluminum Extruded, Side
of Body
RUB RAIL
Bottom edge of the side compartments will be trimmed with a bright aluminum extruded rub rail.
Trim will be 2.12" high with 1.38" flanges turned outward for rigidity.
The rub rails will not be an integral part of the body construction, which allows replacement in the
event of damage.
0784809 Fender Crowns, Rear, Rubber,
w/Removable Liner
BODY FENDER CROWNS
Black rubber fender crowns will be provided around the rear wheel openings.
BODY FENDER LINER
A painted fender liner will be provided. The liners will be removable to aid in the maintenance of
rear suspension components.
0519849 Not Required, Hose, Hard Suction
HARD SUCTION HOSE
Hard suction hose will not be required.
44377Bid #:
PROPOSAL NO. 81217-180004090 Troughs, (2), H.S.H., LS High Side
HOSE TROUGHS
Hard suction hose will be carried above the left compartment in V-shaped troughs and held in
place by chrome plated, quarter turn, spring loaded clamps.
Troughs will be constructed of steel and painted job color.
The size and length of the hard suction hose that will be carried is 10' x 4.50".
0626229 Handrails, Side Pump Panels, Per
Print
HANDRAILS
The handrails will be 1.25" diameter anodized aluminum extrusion, with a ribbed design, to
provide a positive gripping surface.
Chrome plated end stanchions will support the handrail. Plastic gaskets will be used between end
stanchions and any painted surfaces.
Drain holes will be provided in the bottom of all vertically mounted handrails.
Handrails will be provided to meet NFPA 1901 section 15.8 requirements. The handrails will be
installed as noted on the sales drawing.
0004126 Handrails, Beavertail, Standard
HANDRAILS
One (1) vertical handrail, not less than 29.00" long, will be located on each rear beavertail.
0004146 Handrail, Rear, Below Hose Bed, Full
Width
One (1) full width horizontal handrail will be provided below the hose bed at the rear of the
apparatus.
0004154 Handrail, Extra - 10" Long
- One (1) handrail, 10.00" long, will be provided mounted DS side front of body (to assist in
climbing to the top of the body).
0622393 Compt, Air Pack in Fender Panel
AIR PACK STORAGE
A total of two (2) air pack compartment(s) will be provided and located PS forward and DS
rearward. The air pack compartment(s) will be tapered to match the profile of the space available
in the fender. The compartment(s) will be approximately 15.50" wide at the top and 5.00" wide at
the bottom for the wheel cutout. The compartment(s) will be 15.50" tall at the body side
compartment and 6.00" tall at the wheel cutout. The compartment(s) will be 26.00" deep and
have a drain hole.
Inside the compartment, black Dura-Surf friction reducing material will be provided.
A polished stainless steel hinged door with a chrome plated flush lift & turn latch will be provided
to contain the air pack. A dielectric barrier will be provided between the door hinge, hinge
fasteners and the body sheet metal.
0648325 Compt, Air Bottle, Double, Common
Triple Door, Fender Panel
AIR BOTTLE STORAGE (Double)
A quantity of two (2) air bottle compartments, 15.25" wide x 7.75" tall x 26.00" deep, will be
provided on the left side forward of the rear wheels. The triangular door shall cover the double air
bottle opening and the DEF tank access. and on the right side rearward of the rear wheels. The
triangular door shall cover the double air bottle opening and the fuel tank access. . A polished
stainless steel door with a chrome plated flush lift & turn latch will be provided to contain the air
bottle. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body
sheet metal.
Inside the compartment, black rubber matting will be provided.
AIR BOTTLE COMPARTMENT STRAP
A strap shall be provided in the air bottle compartment to help contain the air bottle when the
vehicle is parked on an incline. The strap shall wrap around the neck and attach to the wall of the
compartment.
0004219 Ladder, 30' Duo-Safety 1225-A 3-
Sect
EXTENSION LADDER
There will be a 30', three (3) section, aluminum, Duo-Safety, Series 1225-A extension ladder
provided.
0004230 Ladder, 14' Duo-Safety 775A Roof ROOF LADDER
There will be a 14' aluminum Duo-Safety Series 775-A roof ladder provided.
45377Bid #:
PROPOSAL NO. 81217-180014308 Rack, Zico Quic-Lift, Right Side
LADDER RACK
Ground ladders will be mounted above right side of body compartments in a Zico Quic-Lift electric
ladder lowering system. The ladder rack mounts will be powered by two (2), 12-volt electric
actuators.
The electric controls will be located in such a manner to allow the operator full view of the area in
which the ladders will be lowered.
The electric actuator control will have a master switch and be interlocked to prevent operation
should a compartment door, in the travel area of the ladder bracket, be in the open position.
LADDER RACK INTERLOCK AND NOT STOWED INDICATOR LIGHT
An interlock will be provided to prevent operation of the ladder rack unless the apparatus parking
brake has been activated.
A steady red indicator light will be located on the cab instrument panel and illuminated when the
ladder rack is not in the stowed position. The light will be labeled "Ladder Rack". In addition, the
"Do Not Move Apparatus" light located in the cab will be activated when the ladder rack is not in
the stowed position.
LIGHTS, FLASHING, LADDER RACK
Flashing amber lights facing the front and rear will be provided on the ladder rack and activated
whenever the rack is in the down position.
0014245 Ladder, 10' Duo-Safety Folding 585A,
w/Mounting
FOLDING LADDER
One (1) 10.00' aluminum, Series 585-A, Duo-Safety folding ladder will be installed in a U-shaped
stainless steel trough on top of the right side compartment.
0602877 Pike Pole, Pumper, Provided by Fire
Department, NFPA 2016
PIKE POLE PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, Section 5.9.4 requires one (1) 8 ft or longer pike pole mounted in a
bracket fastened to the apparatus.
The pike pole is not on the apparatus as manufactured. The fire department will provide and
mount the pike pole.
The pike pole(s) will be a Duo-Safety 10' pike pole.
0602875 Pike Pole, 6', Pumper, Provided by
Fire Department, NFPA 2016
6' PIKE POLE PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, Section 5.9.4 requires one (1) 6' pike pole or plaster hook mounted in a
bracket fastened to the apparatus.
The pike pole is not on the apparatus as manufactured. The fire department will provide and
mount the pike pole.
The pike pole(s) will be a Duo-Safety 6' pike pole.
0603809 SP Compt, Long Tool Storage, (2)
Troughs/(1) Tube, Below Tee, S/S
Door, RS
LONG TOOL STORAGE COMPARTMENT
One (1) long tool storage compartment will be provided, recessed below the water tank tee at the
rear of body, on the right side. The compartment will be equipped with one (1) pvc tube and two
(2) troughs to hold long handled tools and have a stainless steel door.
0013929 Compt, (2) Pike Poles Below Tee,
Stainless Steel Door, LS
PIKE POLE COMPARTMENT
One (1) pike pole compartment will be provided, recessed below the water tank tee at the rear of
body, on the left side. The pike pole compartment will be equipped with two (2) pvc tubes to hold
two (2) pike poles and have a stainless steel drop down door.
0791084 SP Tube, 3" PVC, Hydrant Shutoff
Wrench
EQUIPMENT STORAGE
There will be one (1) 3.00" inside diameter PVC mounting tube(s) provided for the mounting of a
hydrant shutoff wrench. The length of the tube will be approximately 7'. The mounting tube will be
located in the compartment on the DS below the water tank tee.
0591804 Step, Folding, Front of Body, Left
Side Only, Trident
STEP
A folding step will be provided on the left side front bulkhead. The step will be bright finished,
non-skid with a black coating. The step can be used as a hand hold with two openings wide
enough for a gloved hand.
0630632 SP Steps, Folding, Rear of Body, w/LED,
Trident, RS Only
REAR FOLDING STEPS
Bright finished, non-skid folding steps with a black coating will be provided at the rear on the right
side. Each step will incorporate an LED light to illuminate the stepping surface. The steps can be
used as a hand hold with two openings wide enough for a gloved hand.
0014387 Step, Corner Step - Extra
One (1) additional corner step will be located In the passenger side back corner of the cargo area
to facilitate access to the cargo area from the front of the water tank. .
0591915 Step, Folding - Extra, Body Only,
Black, Trident
Two (2) additional folding steps will be located DS front bulkhead. The step(s) will be bright
finished, non-skid, with a black coating. The step(s) can be used as a hand hold with two
openings wide enough for a gloved hand.
46377Bid #:
PROPOSAL NO. 81217-180084388 Step, Full Width, Rear Of Body, 8"ADDITIONAL STEP
An 8.00" deep, full width bright aluminum treadplate step will be provided at the rear of the body.
0004460 Pump, Waterous, CMU, 1500 GPM,
Two Stage
PUMP
Pump will be a Waterous CMU 1500 gpm two (2) stage midship mounted centrifugal type.
Pump will be the class "A" type.
Pump will deliver the percentage of rated discharge at pressures indicated below:
- 100% of rated capacity at 150 psi net pump pressure.
- 70% of rated capacity at 200 psi net pump pressure.
- 50% of rated capacity at 250 psi net pump pressure.
Pump body will be close-grained gray iron, bronze fitted, and horizontally split in two (2) sections
for easy removal of the entire impeller shaft assembly (including wear rings).
Pump will be designed for complete servicing from the bottom of the truck, without disturbing the
pump setting or apparatus piping.
Pump case halves will be bolted together on a single horizontal face to minimize a chance of
leakage and facilitate ease of reassembly. No end flanges will be used.
Discharge manifold of the pump will be cast as an integral part of the pump body assembly and
will provide a minimum of three (3) 3.50" openings for flexibility in providing various discharge
outlets for maximum efficiency.
The three (3) 3.50" openings will be located as follows: one (1) outlet to the right of the pump, one
(1) outlet to the left of the pump, and one (1) outlet directly on top of the discharge manifold.
Impeller shaft will be stainless steel, accurately ground to size. It will be supported at each end by
sealed, anti-friction ball bearings for rigid precise support. Impeller will have flame plated hubs
assuring maximum pump life and efficiency despite any presence of abrasive matter in the water
supply.
Bearings will be protected from water and sediment by suitable stuffing boxes, flinger rings, and
oil seals. No special or sleeve type bearings will be used.
0004481 Seal, Grafoil, Waterous
PUMP PACKING
Stuffing boxes will be of the conventional two (2) piece, split-gland type, to permit adjustment or
replacement of Grafoil packing without disturbing the pump. Water will be fed into stuffing box
lantern rings for proper lubrication and cooling when the pump is operating.
Lantern rings will be located at the inner ends of the stuffing boxes, to avoid having to remove
them when replacing pump packing.
Wear rings will be bronze and easily replaceable to restore original pump efficiency and eliminate
the need to replace the entire pump casing due to wear.
0559769 Trans, Pump, Waterous C20 Series
PUMP TRANSMISSION
The pump transmission will be made of a three (3) piece, aluminum, horizontally split casing.
Power transfer to pump will be through a high strength Morse HY-VO silent drive chain. By the
use of a chain rather than gears, 50% of the sprocket will be accepting or transmitting torque,
compared to two (2) or three (3) teeth doing all the work.
Drive shafts will be 2.35" diameter hardened and ground alloy steel and supported by ball
bearings. The case will be designed to eliminate the need for water cooling.
0635600 Pumping Mode, Stationary Only
PUMPING MODE
An interlock system will be provided to ensure that the pump drive system components are
properly engaged so that the apparatus can be safely operated. The interlock system will be
designed to allow stationary pumping only.
0605126 Pump Shift, Air w/Manual Override,
Split Shaft, Interlocked, Waterous
AIR PUMP SHIFT
Pump shift engagement will be made by a two (2) position sliding collar, actuated pneumatically
(by air pressure), with a three (3) position air control switch located in the cab. A manual back-up
shift control will also be located on the left side pump panel.
Two (2) indicator lights will be provided adjacent to the pump shift inside the cab. One (1) green
light will indicate the pump shift has been completed and be labeled "pump engaged". The
second green light will indicate when the pump has been engaged, and that the chassis
transmission is in pump gear. This indicator light will be labeled "OK to pump".
Another green indicator light will be installed adjacent to the hand throttle on the pump panel and
indicate either the pump is engaged and the road transmission is in pump gear, or the road
transmission is in neutral and the pump is not engaged. This indicator light will be labeled
"Warning: Do not open throttle unless light is on".
The pump shift will be interlocked to prevent the pump from being shifted out of gear when the
chassis transmission is in gear to meet NFPA requirements.
The pump shift control in the cab will be illuminated to meet NFPA requirements.
0003148 Transmission Lock-up, EVS TRANSMISSION LOCK-UP
The direct gear transmission lock-up for the fire pump operation will engage automatically when
the pump shift control in the cab is activated.
0004547 Auxiliary Cooling System AUXILIARY COOLING SYSTEM
A supplementary heat exchange cooling system will be provided to allow the use of water from
the discharge side of the pump for cooling the engine water. The heat exchanger will be
cylindrical type and will be a separate unit. The heat exchanger will be installed in the pump or
engine compartment with the control located on the pump operator's control panel. Exchanger will
be plumbed to the master drain valve.
47377Bid #:
PROPOSAL NO. 81217-180004484 Transfer Valve, Manual, Waterous TRANSFER VALVE
Transfer valve design will be of the latest ball type, of all bronze construction incorporating a
hydraulically balanced seal assembly, minimizing leakage around the ball and assuring maximum
pump efficiency.
Transfer valve will operate smoothly and without sticking, even when exposed to sandy or dirty
water.
Transfer valve will be operated manually by means of a handwheel control at the left side pump
panel.
Transfer valve will have the ability to change from series (pressure) operation to parallel (volume)
operation without reducing the operating speed of the engine regardless of the operating
pressure at the pump, thus maintaining an effective fire stream at the nozzle at all times.
0004517 Valve, Relief Intake, Elkhart, Set @
125 PSI
INTAKE RELIEF VALVE
An Elkhart relief valve will be installed on the suction side of the pump preset at 125 psig.
Relief valve will have a working range of 75 psig to 250 psig.
Outlet will terminate below the frame rails with a 2.50" National Standard hose thread adapter
and will have a "do not cap" warning tag.
Control will be located behind an access door at a side pump panel.
0536322 Controller, Pressure, Pierce, Custom
Chassis
PRESSURE CONTROLLER
A Pierce Pressure Governor will be provided. An electric pressure governor will be provided
which is capable of automatically maintaining a desired preset discharge pressure in the water
pump. When operating in the pressure control mode, the system will automatically maintain the
discharge pressure set by the operator (within the discharge capabilities of the pump and water
supply) regardless of flow, within the discharge capacities of the water pump and water supply.
A pressure transducer will be installed in the water discharge of the pump. The transducer
continuously monitors pump pressure sending a signal to the Electronic Control Module (ECM).
The governor can be used in two (2) modes of operation, RPM mode and pressure modes.
In the RPM mode, the governor can be activated after vehicle parking brake has been set. When
in this mode, the governor will maintain the set engine speed, regardless of engine load (within
engine operation capabilities).
In the pressure mode, the governor system can only operate after the fire pump has been
engaged and the vehicle parking brake has been set. When in the pressure mode, the pressure
controller monitors the pump pressure and varies engine speed to maintain a precise pump
pressure. The pressure controller will use a quicker reacting J1939 database for engine control.
A preset feature allows a predetermined pressure or rpm to be set.
A pump cavitation protection feature is also provided which will return the engine to idle should
the pump cavitate. Cavitation is sensed by the combination of pump pressure below 30 psi and
engine speed above 2000 rpm for more than five (5) seconds.
The throttle will be a vernier style control, with a large control knob for use with a gloved hand. A
throttle ready light will be provided adjacent to the throttle control. A large 0.75" RPM display will
be provided to be visible at a glance.
Check engine, and stop engine indicator lights will be provided for easy viewing.
Large 0.75" push buttons will be provided for menu, mode, preset, and silence selections.
The water tank level indicator will be incorporated in the pressure governor.
A fuel level indicator will be incorporated in the pressure controller.
A pump hour meter will be incorporated in the pressure controller.
The pressure controller will incorporate monitoring for engine temperature, oil pressure, fuel level
alarm, and voltage. Pump monitoring will include, pump gearcase temperature, error codes,
diagnostic data, pump service reminders, and time stamped data logging, to allow for fast
accurate trouble shooting. It will also notify the driver/engineer of any problems with the engine
and the apparatus. Complete understandable messages will be provided in a 20-character
display, providing for fewer abbreviations in the messages. An automatic dim feature will be
included for night operations.
The pressure controller will include a USB port for easy software upgrades, which can be
downloaded through a USB memory stick, eliminating the need for a laptop for software
installations.
A complete interactive manual will be provided with the pressure controller.
0072153 Primer, Trident, Air Prime, Air
Operated
PRIMING PUMP
The priming pump will be a Trident Emergency Products compressed air powered, high
efficiency, multistage venturi based AirPrime System, conforming to standards outlined in the
current edition of NFPA 1901.
All wetted metallic parts of the priming system are to be of brass and stainless steel construction.
One (1) priming control will open the priming valve and start the pump primer.
48377Bid #:
PROPOSAL NO. 81217-180658368 Thermal Relief Valve, OPM, w/Red
Warning Light, Waterous Pump
THERMAL RELIEF VALVE
A Waterous Overheat Protection Manager (OPM) will be included on the pump that monitors
pump water temperature and opens to relieve water to cool the pump when the temperature of
the pump water exceeds 140 Degrees F (60 C) and a red warning light that is triggered when the
water in the pump reaches 180 F (82 C).
The warning light will act as an additional protection device if the temperature in the pump keeps
rising after the valve opens. The warning light with a test switch will be mounted on the pump
operator panel.
The discharge line will be plumbed to ground.
0780364 Manuals, Pump, (2) Total, Electronic
Copies
PUMP MANUALS
There will be a total of two (2) pump manuals provided by the pump manufacturer and furnished
with the apparatus. The manuals will be provided by the pump manufacturer in the form of two (2)
electronic copies. Each manual will cover pump operation, maintenance, and parts.
0603128 Plumbing, Stainless Steel and Hose,
Two Stage Pump
PLUMBING, STAINLESS STEEL AND HOSE
All inlet and outlet lines will be plumbed with either stainless steel pipe, hydraulic type hose or
synthetic rubber hose reinforced with hi-tensile polyester braid. All hose's will be equipped with
brass or stainless steel couplings. All stainless steel hard plumbing will be a minimum of a
schedule 10 wall thickness.
Where vibration or chassis flexing may damage or loosen piping or where a coupling is required
for servicing, the piping will be equipped with victaulic or rubber couplings.
Plumbing manifold bodies will be ductile cast iron or stainless steel.
All piping lines are to be drained through a master drain valve or will be equipped with individual
drain valves. All drain lines will be extended with a hose to drain below the chassis frame.
All water carrying gauge lines will be hydraulic or reinforced poly hose.
All piping, hose and fittings will have a minimum of a 700 PSI hydrodynamic pressure rating.
0795135 Plumbing, Stainless Steel, w/Foam
System
PLUMBING, FOAM SYSTEM
All piping that is in contact with the foam concentrate or foam/water solution will be stainless
steel. The fittings will be stainless steel or brass. Cast iron pump manifolds will be allowed.
0004645 Inlets, 6.00" - 1250 GPM or Larger
Pump
MAIN PUMP INLETS
A 6.00" pump manifold inlet will be provided on each side of the vehicle. The suction inlets will
include removable die cast zinc screens that are designed to provide cathodic protection for the
pump, thus reducing corrosion in the pump.
0004646 Cap, Main Pump Inlet, Long Handle,
NST, VLH
MAIN PUMP INLET CAP
The main pump inlets will have National Standard Threads with a long handle chrome cap.
The cap will be the Pierce VLH, which incorporates an exclusive thread design to automatically
relieve stored pressure in the line when disconnected.
0677247 Valves, Elkhart Unibody and
Jamesbury
VALVES
All 4.00" and smaller ball valves will be Elkhart Unibody series. Seats will be self-adjusting for
minimum operating torque and maximum abrasion resistance. The Elkhart valves will have an
automatic locking feature to hold the ball in any throttle position at any operating pressure. The
valve body design will allow any actuator to be mounted to the body. All 6.00" or larger butterfly
valves will be S/S high pressure Jamesbury.
0004660 Inlet, Left Side, 2.50"
LEFT SIDE INLET
There will be one (1) auxiliary inlet with a 2.50" valve at the left side pump panel, terminating with
a 2.50" (F) National Standard hose thread adapter.
The auxiliary inlet will be provided with a strainer, chrome swivel and plug.
0029147 Not Required, Inlet, Right Side
49377Bid #:
PROPOSAL NO. 81217-180004686 Valve, Inlet(s) Recess Behind Panel,
Side Cntrl
The location of the valve for the one (1) inlet will be behind the pump panel.
0505132 Anode, Zinc, Pair, Pump, 1-Inlet & 1
Discharge Side
ANODE, INLET
A pair of replaceable sacrificial .75" magnesium anodes will be provided in the water pump to
protect the pump from corrosion. One (1) will be placed in the inlet side of the pump and the other
in the discharge side of the pump.
0004700 Control, Inlet, at Valve
INLET CONTROL
The side auxiliary inlet(s) will incorporate a quarter-turn ball valve with the control located at the
inlet valve. The valve operating mechanism will indicate the position of the valve.
0092569 No Rear Inlet (Large Dia) Requested
0092696 Not Required, Cap, Rear Inlet
0064116 No Rear Inlet Actuation Required
0009648 No Rear Intake Relief Valve Required
on Rear Inlet
0092568 No Rear Auxiliary Inlet Requested
0563738 Valve, .75" Bleeder, Aux. Side Inlet,
Swing Handle
INLET BLEEDER VALVE
A 0.75" bleeder valve will be provided for each side gated inlet. The valves will be located behind
the panel with a swing style handle control extended to the outside of the panel. The handles will
be chrome plated and provide a visual indication of valve position. The swing handle will provide
an ergonomic position for operating the valve without twisting the wrist and provides excellent
leverage. The water discharged by the bleeders will be routed below the chassis frame rails.
0014751 Tank to Pump, (1) 3.00" Valve, 3.00"
Plumbing, Reverse Linkage
TANK TO PUMP
The booster tank will be connected to the intake side of the pump with heavy duty piping and a
quarter turn 3.00" full flow line valve with the control remotely located at the operator's panel. The
tank to pump line will run straight (no elbows) from the pump into the front face of the water tank
and down into the tank sump. A rubber coupling will be included in this line to prevent damage
from vibration or chassis flexing.
The control on the pump panel will be "in" when the valve is open and "out" when the valve is
closed.
A check valve will be provided in the tank to pump supply line to prevent the possibility of "back
filling" the water tank.
0004905 Outlet, Tank Fill, 1.50"
TANK REFILL
A 1.50" combination tank refill and pump re-circulation line will be provided, using a quarter-turn
full flow ball valve controlled from the pump operator's panel.
0004940 Outlet, Left Side, 2.50"
LEFT SIDE DISCHARGE OUTLETS
There will be two (2) discharge outlets with a 2.50" valve on the left side of the apparatus,
terminating with a 2.50" (M) National Standard hose thread adapter.
0005026 Outlet, Left Side, 1.50" w/2" Plumbing
There will be one (1) discharge outlet with a 2.00" valve on the left side of the apparatus,
terminating with a 1.50" (M) National Standard hose thread adapter.
0004945 Outlet, Right Side, 2.50"
RIGHT SIDE DISCHARGE OUTLETS
There will be one (1) discharge outlet with a 2.50" valve on the right side of the apparatus,
terminating with a 2.50" (M) National Standard hose thread adapter.
0092571 Not Required, Outlets, Right Side
Additional
0058648 SP Outlet, (2) 3.50" w/3.50" Akron
Valve, Right, Handwheel
LARGE DIAMETER DISCHARGE OUTLET
There will be two (2) 3.50" discharge outlets with 3.50" Akron valves, with a 3.00" ball, installed
on the right side of the apparatus, terminating with (M) 3.50" National Standard hose thread
adapters.
The discharge outlets will be actuated with a handwheel control at the pump operator's control
panel.
50377Bid #:
PROPOSAL NO. 81217-180092572 Not Required, Outlet, Front
0004995 Outlet, Rear, 2.50"
REAR DISCHARGE OUTLET
There will be one (1) discharge outlet piped to the rear of the hose bed, right side, installed so
proper clearance is provided for spanner wrenches or adapters. Plumbing will consist of 2.50"
piping along with a 2.50" full flow ball valve with the control from the pump operator's panel.
0092574 Not Required, Outlet, Rear,
Additional
0004990 Outlet, Front HB, 2.50" w/2.50"
Plumbing
FRONT OF HOSE BED DISCHARGE OUTLET
There will be one (1) discharge outlet discharge(s) piped to the front of the hose bed and located
PS most bed (150' x 2.50" pre-connected). Plumbing will consist of 2.50" piping with a 2.50" full-
flow ball valve controlled at the pump operator's panel. The discharge(s) will terminate with a
2.50" (M) National Standard hose thread adapter.
0085076 Caps for 1.50" to 3.00" Discharge,
VLH
DISCHARGE CAPS
Chrome plated, rocker lug, caps with chains will be furnished for all side discharge outlets.
The caps will be the Pierce VLH, which incorporates an exclusive thread design to automatically
relieve stored pressure in the line when disconnected.
0563739 Valve, 0.75" Bleeder, Discharges,
Swing Handle
OUTLET BLEEDER VALVE
A 0.75" bleeder valve will be provided for each outlet 1.50" or larger. Automatic drain valves are
acceptable with some outlets if deemed appropriate with the application.
The valves will be located behind the panel with a swing style handle control extended to the
outside of the side pump panel. The handles will be chrome plated and provide a visual indication
of valve position. The swing handle will provide an ergonomic position for operating the valve
without twisting the wrist and provides excellent leverage. Bleeders will be located at the bottom
of the pump panel. They will be properly labeled identifying the discharge they are plumbed in to.
The water discharged by the bleeders will be routed below the chassis frame rails.
0005091 Elbow, Left Side Outlets, 45 Degree,
2.50" FNST x 2.50" MNST, VLH
LEFT SIDE OUTLET ELBOWS
The 2.50" discharge outlets located on the left side pump panel will be furnished with a 2.50" (F)
National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45
degree elbow.
The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically
relieve stored pressure in the line when disconnected.
0792731 SP Elbow, Left Side Outlets, 30 Deg,
1.50" FNST x 1.50" MNST, VLH,
Additional
ADDITIONAL LEFT SIDE OUTLET ELBOWS
The 1.50" discharge outlets, located on the left side pump panel, shall be furnished with a 1.50"
(F) National Standard hose thread x 1.50" (M) National Standard hose thread, chrome plated, 30
degree elbow.
The elbow shall incorporate a thread design to automatically relieve stored pressure in the line
when disconnected.
0025091 Elbow, Right Side Outlets, 45
Degree, 2.50" FNST x 2.50" MNST,
VLH
RIGHT SIDE OUTLET ELBOWS
The 2.50" discharge outlets located on the right side pump panel will be furnished with a 2.50" (F)
National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45
degree elbow.
The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically
relieve stored pressure in the line when disconnected.
0089584 Not Required, Elbow, Right Side
Outlets, Additional
0045091 Elbow, Rear Outlets, 45 Degree,
2.50" FNST x 2.50" MNST, VLH
REAR OUTLET ELBOWS
The 2.50" discharge outlets located at the rear of the apparatus will be furnished with a 2.50" (F)
National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45
degree elbow.
The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically
relieve stored pressure in the line when disconnected.
0085695 Not Required, Elbow, Rear Outlets,
Large, Additional
51377Bid #:
PROPOSAL NO. 81217-180757169 SP Elbow, Large Dia Outlets, (2)45
Degree 3.50" FNST x 3.50"
MNST,VLH w/Adapter/Cap
LARGE DIAMETER OUTLET ELBOWS
The 2 (two) 3.50" discharge outlets, located on the right side pump panel, will be furnished with a
3.50" (F) National Standard hose thread x 3.50" (M) National Standard hose thread, chrome
plated, 45 degree elbow.
An adapter connected to the elbow will be furnished (2.50" M x 3.50" F)
A 2.50" cap with chain will be provided.
The elbow will incorporate a thread design to automatically relieve stored pressure in the line
when disconnected (no exception).
0005080 Reducer, 2.50" FNST x 1.50" MNST,
w/Cap
REDUCER
There will be four (4) adapters with 2.50" FNST x 1.50" MNST threads and a 1.50" chrome plated
cap installed on both DS 2.50" discharges, one (1) PS 2.50" discharge, and the rear body 2.50"
discharge.
0062133 Control, Outlets, Manual, Pierce HW
if applicable
DISCHARGE OUTLET CONTROLS
The discharge outlets will incorporate a quarter-turn ball valve with the control located at the
pump operator's panel. The valve operating mechanism will indicate the position of the valve.
If a handwheel control valve is used, the control will be a minimum of a 3.9" diameter stainless
steel handwheel with a dial position indicator built in to the center of the handwheel.
0638545 Outlet, 3.00" Deluge Riser, Elkhart
Valve w/Handwheel
DELUGE RISER
A 3.00" deluge riser will be installed above the pump in such a manner that a monitor can be
mounted and used effectively. Piping will be installed securely so no movement develops when
the line is charged. The riser will be gated and controlled at the pump operator's panel. The outlet
will include an Elkhart Unibody valve with a Pierce handwheel control.
0602037 SP Monitor, Elkhart Stinger 8297-35,
3.50" NST F Inlet portable base
MONITOR
An Elkhart Model 8297 Stinger monitor will be properly installed on the deluge riser.
This monitor will include both the fixed base and the portable base with 3.50" NSTF swivel inlet.
The monitor will be painted to match the body.
0046997 Nozzle, Elkhart ST-194, Stacked Tips
and 282 A Shaper
MONITOR NOZZLE
An Elkhart #ST-194 Elk-o-Lite quad stacked deluge tips will be provided with a 282 A Elkhart
stream shaper.
Tip sizes will be 1.375", 1.50", 1.75" and 2.0"
0005072 Deluge Mount, 3" ANSI 4 Bolt Flange The deluge riser will have a 3.00" four (4)-bolt flange for mounting the monitor.
0029167 Crosslays Sngl Sheet Unpainted,
(2+) 1.50", Std. Cap
CROSSLAY HOSE BEDS
Two (2) crosslays with 1.50" outlets will be provided. Each bed to be capable of carrying 200' of
1.75" double jacketed hose and will be plumbed with 2.00" i.d. pipe and gated with a 2.00"
quarter turn ball valve.
Outlets to be equipped with a 1.50" National Standard hose thread 90 degree swivel located in
the hose bed so that hose may be removed from either side of apparatus.
The crosslay controls will be at the pump operator's panel.
The center crosslay dividers will be fabricated of 0.25" aluminum and will provide adjustment from
side to side. The divider will be unpainted with a brushed finish.
Vertical scuffplates constructed of stainless steel will be provided at the front and rear ends of the
bed on each side of vehicle.
Crosslay bed flooring will consist of removable perforated brushed aluminum.
0092183 Deadlay(s) No Plumbing, Spl
Capacity,
DEADLAY HOSE BEDS
One (1) deadlay bed, without plumbing, will be provided above the pump compartment capable of
carrying 400' x 1.50" (rubber jacket).
The center crosslay dividers will be fabricated of .25" aluminum and will provide adjustment from
side to side. The divider will be unpainted with a DA finish. The remainder of the crosslay bed will
be painted job color.
Stainless steel vertical scuffplates will be provided at hose bed ends (each side of vehicle).
Bottom of hose bed ends (each side) will also be equipped with a stainless steel scuffplate.
Deadlay bed flooring will consist of removable perforated brushed aluminum.
0029260 Not Required, Speedlays
0500535 Not Required, Hose Restraint,
Crosslay/Speedlay
52377Bid #:
PROPOSAL NO. 81217-180567918 Cover, Crosslay, Hinged Alum
Treadplate, Weighted Vinyl Flaps on
Sides, Cords
CROSSLAY COVER
A hinged aluminum treadplate cover will be installed over the crosslay hose beds. It will include a
latch at each end of the cover to hold it securely in place, a chrome grab handle at each end for
opening and closing the cover and a foam rubber gasket where the cover comes into contact to a
painted surface.
A black vinyl cover permanently attached to the aluminum treadplate cover will be provided over
each end of the crosslay hose beds. The cover will have bungee cords attached at each lower
corner. The bottom of the flaps will be weighted with a chain.
0034554 SP Crosslays, 6.00" Lower Than
Standard
CROSSLAY 6.00" LOWER THAN STD
The crosslays will be lowered 6.00" from standard.
0005216 Reel, Booster, Aluminum - Over
Pump, Left
BOOSTER HOSE REEL
A Hannay electric rewind booster hose reel will be installed over the pump in a recessed open
compartment on the left side of the apparatus. Reel will be fabricated of aluminum and have
highly polished end discs.
A polished stainless steel roller and guide assembly will be mounted on the reel side of the
apparatus.
Discharge control will be provided at the pump operator's panel. Plumbing to the reel will consist
of 1.50" Aeroquip hose and a 1.50" valve.
0011060 Switch, Reel Rewind - One at Pump
Panel
Reel motor will be protected from overload with a circuit breaker rated to match the motor.
An electric rewind control switch will be installed on the reel side pump panel.
0540028 SP Hose, Booster - 150' of .75" Niedner
ReelTex
Neidner ReelTex booster hose, .75" diameter and 150 feet, will be provided.
Working pressure of the booster hose will be a minimum of 600 psi.
The Booster hose will be located: in the cargo compartment on the DS
0050051 Capacity, Hose Reel 150' of .75"
Capacity of the hose reel will be 150 feet of .75" booster hose.
0007428 Nozzle for Booster Reel Not Req'd
0774720 SP Foam Sys, Waterous, Aquis 3 (Single
Agent)
FOAM CONCENTRATE PROPORTIONING SYSTEM
A Waterous Aquis 3.0 electronic, direct injection foam system will be provided as the means for
the proportioning of foam concentrate into the water stream.
This system will be a single agent system capable of handling Class A foam concentrates, as well
as most Class B foam concentrates.
The foam system will be plumbed to seven (7) discharges. The discharges capable of dispensing
foam will be DS pump panel 1.50", PS pump panel 2.50", both crosslays, PS rear body 2.50", PS
hosebed 2.50", and the booster reel.
The foam proportioning system operation will be based on a direct measurement of water flows,
and remain consistent within the specified flow and pressure. The system will be equipped with a
digital electronic control display on the pump panel. Incorporated within the control display will be
a microprocessor, which receives input from the system flow meter while also monitoring the
foam concentrate pump output. The microprocessor will compare the values of the water flow
versus the foam flow, to ensure the proportion rate is accurate.
One (1) paddle wheel will be installed to monitor all foam discharges.
Push button control for the class "A" foam proportioning rate will allow a ratio from 0.1 percent to
1.0 percent, in 0.1 percent increments adjustable from the electronic control head.
Push button control for the class "B" foam proportioning rate will allow a ratio for 1.0, 3.0 or 6.0
percent increments adjustable from the control head.
A 3 gpm @ 150 psi positive displacement triplex plunger pump will be powered by a 0.5 hp 12
vdc electric motor.
One (1) check valve will be installed in the plumbing to prevent foam from contaminating the
water pump. The check valve will be approved by the foam system manufacturer.
0012126 Not Required, CAF Compressor
0771139 Foam Refill Pump, Waterous
FoamFill, Single Cell/Tank
FOAM TANK REFILL SYSTEM, SINGLE CELL/TANK
A Waterous foam cell/tank foam refill system will be provided for the single agent foam system.
The foam refill pump will deliver a maximum flow of 10 gpm of foam concentrate. The foam refill
pump will be plumbed to the single agent foam cell/tank allowing the end user to refill the foam
cell/tank from the ground. A 1.00" female quick disconnect fitting and dust cap will be provided. A
three-way fill/flush valve will be provided to allow the operator to easily flush the system after
each use. A foam refill control panel will be provided. The Waterous foam fill connections and
control panel will be located on the Left Pump Panel pump panel.
One (1) 6ft long, 1.00" ID, foam pick-up wand with reinforced hose and mating 1.00" male quick
disconnect fitting will be provided in loose equipment.
53377Bid #:
PROPOSAL NO. 81217-180005446 Foam Cell, 20 Gallon, Not Reduce
Water
FOAM TANK
The foam tank will be an integral portion of the polypropylene water tank. The cell will have a
capacity of 20 gallons of foam with the intended use of Class A foam. The foam cell will not
reduce the capacity of the water tank. The foam cell will have a screen in the fill dome and a
breather in the lid.
0091036 Drain, 1.00" Foam Tank #1 FOAM TANK DRAIN
The foam tank drain will be a 1.00" drain valve located inside the pump compartment accessible
through a door on the right side pump panel.
0091079 Not Required, Foam Tank #2
0091112 Not Required, Foam Tank #2 Drain
0005498 Pump House, Side Control, 52"
PUMP COMPARTMENT
The pump compartment will be separate from the hose body and compartments so that each may
flex independently of the other. It will be a fabricated assembly of steel tubing, angles and
channels which supports both the fire pump and the side running boards.
The pump compartment will be mounted on the chassis frame rails with rubber biscuits in a four
point pattern to allow for chassis frame twist.
Pump compartment, pump, plumbing and gauge panels will be removable from the chassis in a
single assembly.
PUMP MOUNTING
Pump will be mounted to a substructure which will be mounted to the chassis frame rail using
rubber isolators. The mounting will allow chassis frame rails to flex independently without damage
to the fire pump.
PUMP CONTROL PANELS (Side Control)
All pump controls and gauges will be located at the left side of the apparatus and properly
marked.
The pump panel on the right side will be removable with lift and turn type fasteners. The left side
will be fastened with screws.
The control panels will be 52.00" wide.
The gauge and control panels will be two (2) separate panels for ease of maintenance.
The side gauge panel will be hinged at the bottom with a full length stainless steel hinge. The
fasteners used to hold the panel in the upright position will be quarter turn type. Vinyl covered
cable or chains will be used to hold the gauge panel in the dropped position.
Polished stainless steel trim collars will be installed around all inlets and outlets.
All push/pull valve controls will have 1/4 turn locking control rods with polished chrome plated zinc
tee handles. Guides for the push/pull control rods will be chrome plated zinc castings securely
mounted to the pump panel. Push/pull valve controls will be capable of locking in any position.
The control rods will pull straight out of the panel and will be equipped with universal joints to
eliminate binding.
The identification tag for each valve control will be recessed in the face of the tee handle.
All discharge outlets will have color coded identification tags, with each discharge having its own
unique color. Color coding will include the labeling of the outlet and the drain for each
corresponding discharge.
All line pressure gauges will be mounted in individual chrome plated castings with the
identification tag recessed in the casting below the gauge. All remaining identification tags will be
mounted on the pump panel in chrome plated bezels. Mounting of the castings and identification
bezels will be done with a threaded peg cast on the back side of the bezel or screws.
0594577 Pump Panel Configuration, Match
Previous Unit, as Close as Possible
PUMP PANEL CONFIGURATION
The left side and right side pump panel configurations will match those on 30272 .
Option differences may be evident and an identical match is not possible. An as close as possible
similarity will be the intent.
0005525 Material, Pump Panels, Side Control
Brushed Stainless
PUMP AND GAUGE PANEL
The pump and gauge panels will be constructed of stainless steel with a brushed finish. A
polished aluminum trim molding will be provided on both sides of the pump panel.
0547283 SP Panel, Pump Access, Right Side
Only, Split Panel, "Southern Marin"
The right side pump panel shall be split horizontally with the top section of the panel above the
outlets removable and fastened with swell latches. The panel shall be configured so that the
panel will open fully without having to remove any items (Flood lights on the back of the cab etc.
If the hinged panel needs to be smaller than normal to achieve this the customer is ok with this.
The lower section of the panel shall be fastened with 1/4" stainless steel truss head screws.
0035501 Pump House Structure, Std Height
0583824 Light, Pump Compt, Wln 3SC0CDCR
LED White
PUMP COMPARTMENT LIGHT
There will be one (1) Whelen®, Model 3SC0CDCR, 3.00" white 12 volt DC LED light(s) with
Whelen, Model 3FLANGEC, flange(s) installed in the pump compartment.
There will be a switch accessible through a door on the pump panel included with this installation.
54377Bid #:
PROPOSAL NO. 81217-180586382 Gauges, Engine, Included With
Pressure Controller
Engine monitoring graduated LED indicators will be incorporated with the pressure controller.
Also provided at the pump panel will be the following:
- Master Pump Drain Control
0005601 Throttle Included w/ Pressure
Controller
0549333 Indicators, Engine, Included with
Pressure Controller
0005625 Gauge, Fuel - Fuel Gauge
0080713 Control, Air Horn At Pump Panel
w/Red Button, Labeled "Evacuation"
AIR HORN BUTTON
An air horn control button will be provided at the pump operator's control panel. This button will
be red in color and properly labeled "Evacuation".
0058796 Gauge Panel, Vertically Hinged
HINGED GAUGE PANEL
The pump gauge panel will be vertically hinged with quarter turn lift and turn latches for access.
0533671 Gauge Panel, Hinged at Bottom HINGED GAUGE PANEL
The pump gauge panel will be hinged at the bottom with quarter turn lift and turn latches for
access.
0001493 Tag, Special Wording, Discharge
SPECIAL LABEL
There will be twelve (12) special label/s provided and installed NO. 1 CROSSLAY NO. 2
CROSSLAY DELUGE PASSENGER FHB PRECONNECT PASSENGER REAR DISCHARGE
REEL DISCHARGE 1.50" DS DISCHARGE NO. 1 DS DISCHARGE NO. 2 PS DISCHARGE NO.
3 DS DISCHARGE PS LARGE DIAMETER DISCHARGE 1 PS LARGE DIAMETER DISCHARGE
2 . Each label will be worded as follows, PRECONNECT #1 PRECONNECT #2 DECK GUN
OFFICER'S SIDE HOSEBED OFFICER'S SIDE REAR DISCHARGE HOSE REEL DISCHARGE
5 DISCHARGE 1 DISCHARGE 6 DISCHARGE 2 DISCHARGE 3 DISCHARGE 4.
0511078 Gauges, 4.00" Master, Class 1, 30"-0
-600psi
VACUUM AND PRESSURE GAUGES
The pump vacuum and pressure gauges will be liquid filled and manufactured by Class 1
Incorporated ©.
The gauges will be a minimum of 4.00" in diameter and will have white faces with black lettering,
with a pressure range of 30.00"-0-600#.
Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded
retaining nut.
The pump pressure and vacuum gauges will be installed adjacent to each other at the pump
operator's control panel.
Test port connections will be provided at the pump operator's panel. One will be connected to the
intake side of the pump, and the other to the discharge manifold of the pump. They will have 0.25
in. standard pipe thread connections and non-corrosive polished stainless steel or brass plugs.
They will be marked with a label.
This gauge will include a 10 year warranty against leakage, pointer defect, and defective bourdon
tube.
0511100 Gauge, 2.00" Pressure, Class 1, 30"-
0-400psi
PRESSURE GAUGES
The individual "line" pressure gauges for the discharges will be Class 1© interlube filled.
They will be a minimum of 2.00" in diameter and have white faces with black lettering.
Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded
retaining nut.
Gauges will have a pressure range of 30"-0-400#.
The individual pressure gauge will be installed as close to the outlet control as practical.
This gauge will include a 10 year warranty against leakage, pointer defect, and defective bourdon
tube.
0536428 Gauge, Water Level, Pierce, In
pressure Controller
WATER LEVEL GAUGE
An electric water level gauge will be incorporated in the pressure controller that registers water
level by means of 9 LEDs. They will be at 1/8 level increments with a tank empty LED. The LEDs
will be a bright type that is readable in sunlight, and have a full 180-degree of clear viewing.
To further alert the pump operator, the gauge will have a warning flash when the tank volume is
less than 25%, and will have "Down Chasing LEDs when the tank is almost empty.
The level measurement will be ascertained by sensing the head pressure of the fluid in the tank
or cell.
55377Bid #:
PROPOSAL NO. 81217-180060753 Water Level Gauge, Wln PSTANK,
LED 1-Light, 4-Level
WATER LEVEL GAUGE
There will be two (2) additional water level indicator, Whelen®, Model PSTANK, LED module
installed one (1) each side rearward of crew cab doors.
This light module will include four (4) colored levels, and function similar to the water level
indicator located at the operators panel:
First green module indicates a full water level
Second blue module indicates a water level above 3/4 full
Third amber module indicates a water level above 1/2 full
Last red module indicates a water level above 1/4 full and empty
Above 1/4 this light will be steady burning
At empty this light will be flashing
This module will be activated when the battery switch is on.
0062992 Gauge, Foam Level, (1) Tank, Class
1, 5lt
FOAM LEVEL GAUGE
An electronic foam level gauge will be provided on the operator's panel that registers foam level
by means of five (5) colored LED lights. The lights will be durable, ultra-bright five (5) LED design
viewable through 180 degrees. The foam level indicators will be as follows:
100 percent = Green
75 percent = Yellow
50 percent = Yellow
25 percent = Yellow
Refill = Red
The light will flash when the level drops below the given level indicator to provide an eighth of a
tank indication. To further alert the pump operator, the lights will flash sequentially when the foam
tank is empty.
The level measurement will be based on the sensing of head pressure of the fluid in the tank.
The display will be constructed of a solid plastic material with a chrome plated die cast bezel to
reduce vibrations that can cause broken wires and loose electronic components. The
encapsulated design will provide complete protection from foam and environmental elements. An
industrial pressure transducer will be mounted to the outside of the tank. The display will be able
to be calibrated in the field and will measure head pressure to accurately show the tank level.
0593161 Light Shield, S/S LED
LIGHT SHIELD
There will be a polished, 16 gauge stainless steel light shield installed over the pump operator's
panel.
There will be 12 volt DC white LED lights installed under the stainless steel light shield to
illuminate the controls, switches, essential instructions, gauges, and instruments necessary for
the operation of the apparatus. These lights will be activated by the pump panel light switch.
Additional lights will be included every 18.00" depending on the size of the pump house.
One (1) pump panel light will come on when the pump is in ok to pump mode.
There will be a light activated above the pump panel light switch when the parking brake is set.
This is to afford the operator some illumination when first approaching the control panel.
There will be a green pump engaged indicator light activated on at the operator's panel when the
pump is shifted into gear from inside the cab.
0682498 Light Shield/Step 8", PS LED, P25
LED Stp Lt
ADDITIONAL STEP/LIGHT SHIELD
There will be an additional aluminum treadplate stepping surface no less than 8.00" deep and
properly reinforced to support a man's weight, installed over the passenger's side pump panel.
There will be 12 volt DC white LED lights installed under the step to illuminate the controls,
switches, essential instructions, gauges, and instruments necessary for the operation of the
apparatus. These lights will be activated by the pump panel light switch. Additional lights will be
included every 18.00" depending on the size of the pump house.
There will be one (1) white LED, step light provided above the step. In order to ensure
exceptional illumination, each step light will provide a minimum of 25 foot-candles (fc) covering an
entire 15.00" x 15.00" square placed 10.00" below the light and a minimum of 1.5 fc covering an
entire 30.00" x 30.00" square at the same 10.00" distance below the light. The step light will be
activated by the pump panel light switch.
0508020 Air Horn, (1) Hadley, 6" Round, In
Bumper
AIR HORN SYSTEM
One (1) Hadley round air horn with 6.00" bell will be recessed in the front bumper. The air horn
system will be piped to the air brake system wet tank utilizing 0.38" tubing. A pressure protection
valve will be installed to prevent the loss of air in the brake system.
0606839 Location, Air Horn, Bumper, Left
Side, Outside Frame, Inboard (Pos
#6)
Air Horn Location
The air horn will be located on the left side of the bumper, just outside of the frame rail.
0006063 Control, Air Horn, Horn Ring, PS Foot
Sw
AIR HORN CONTROL
The air horns will be actuated by a foot switch on the officer's side and by the horn button in the
steering wheel. The driver will have the option to control the air horns or the chassis horns from
the horn button by means of a selector switch located on the instrument panel.
0688049 Siren, Federal EQ2B-200, 200 Watt
ELECTRONIC SIREN
There will be a Federal, Model EQ2B-200, electronic siren with noise canceling
microphone provided.
This siren to be active when the battery switch is on and that emergency master switch is on.
56377Bid #:
PROPOSAL NO. 81217-180510206 Location, Elect Siren, Recessed
Overhead In Console
Electronic siren head will be recessed in the overhead console above the engine tunnel in the
center.
0006150 Control, Elec Siren, DS & PS Foot Sw Siren will be actuated by two (2) foot switches, one (1) located on the officer's side and one (1) on
the driver's side.
0601330 Speaker, (1) Federal, ES100C
w/ESFMT-EF Recess Mnt & S/S
Grille
SPEAKER
There will be one (1) Federal Signal DynaMax®, Model ES100, 100 watt speaker provided. The
speaker will use a Federal Signal, Model ESFMT-EF, recess mount with stainless steel grille. The
speaker will be connected to the siren amplifier.
0601555 Location, Speaker, Frt Bumper,
Recessed, Left Side, Outside
Frame,Outbrd (Pos 7)
The speaker will be recessed in the left side of the front bumper, towards the outside.
0792069 SP Lightbar, Wln, Freedom IV-D, 72",
ARRRRRW_srsr_WRRRRRA
FRONT ZONE UPPER WARNING LIGHTS
There will be a 72.00" Whelen® Freedom™ IV lightbar mounted on the cab roof.
The lightbar will include the following:
One (1) amber flashing LED module in the driver's side rear corner position.
One (1) red flashing LED module in the driver's end position.
One (1) red flashing LED module in the driver's side front corner position.
One (1) red flashing LED module in the driver's side first front position.
One (1) red flashing LED module in the driver's side second front position.
One (1) red flashing LED module in the driver's side third front position.
One (1) white flashing LED module in the driver's side fourth front position.
Open in the driver's side fifth front position.
One (1) red steady burning LED module in the driver's side front center position.
One (1) red steady burning LED module in the passenger's side front center position.
Open in the passenger's side fifth front position.
One (1) white flashing LED module in the passenger's side fourth front position.
One (1) red flashing LED module in the passenger's side third front position.
One (1) red flashing LED module in the passenger's side second front position.
One (1) red flashing LED module in the passenger's side first front position.
One (1) red flashing LED module in the passenger's side front corner position.
One (1) red flashing LED module in the passenger's end position.
One (1) amber flashing LED module in the passenger's side rear corner position.
There will be clear lenses included on the lightbar.
There will be a switch in the cab on the switch panel to control the red and white LEDs.
There will be a switch in the cab on the switch panel to control the amber LEDs.
The white flashing LEDs will be deactivated when the parking brake is applied.
The six (6) red flashing LED modules in the front positions and the two (2) amber flashing LED
modules in the rear corner positions may be load managed when the parking brake is applied.
0540384 Lights, Front Zone, Wln M6*C LED,
Clear Lens, in Common Bzl
LIGHTS, FRONT ZONE LOWER
Two (2) Whelen model M6*C LED flashing warning lights will be installed on the cab face above
the headlights, in a common bezel with the directional lights.
The driver's side front warning light to be red.
The passenger's side front warning light to be red.
Both lights will include a clear lens.
There will be a switch located in the cab on the switch panel to control the lights.
0558676 Daytime Running Lights, Headlights,
Qtm, Vel/Imp, Enf/AXT-MUX, DCF
(Low Beam)
DAYTIME RUNNING LIGHTS (HEADLIGHTS)
The low-beam headlights used as daytime running lights will be activated with the following
measures:
Ignition switch is turned on.
Parking brake is released.
These lights will be deactivated with any one of the following measures:
Headlight switch is turned on.
High-beam flash is turned on.
Parking brake is set.
0653937 Flasher, Headlight Alternating
HEADLIGHT FLASHER
The high beam headlights will flash alternately between the left and right side.
There will be a switch installed in the cab on the switch panel to control the high beam flash. This
switch will be live when the battery switch and the emergency master switches are on.
The flashing will automatically cancel when the hi-beam headlight switch is activated or when the
parking brake is set.
57377Bid #:
PROPOSAL NO. 81217-180540679 Lights, Side Zone Lower, Wln M6*C
LED, Clear Lens 2pr
SIDE ZONE LOWER LIGHTING
There will be four (4) Whelen®, Model M6*C, flashing LED warning lights with chrome trim
installed per the following:
Two (2) lights, one (1) each side on the front cab corner. The side front lights to be red.
Two (2) lights, one (1) each side above rear wheels. The side rear lights to be red.
The lights will include a clear lenses.
There will be a switch in the cab on the switch panel to control the lights.
0505919 Lights, Side, Wln TIR3, LED,
RS*03ZCR Horizontal, Clear Lens,
Crm Flng 1st
SIDE WARNING LIGHTS
There will be two (2) pairs of Whelen, Model RS*03ZCR, LED flashing lights provided in the rub
rail centered, one (1) each below D1, D3, P1 and P3.
The color of the lights will be amber.
The lights will be provided with a Whelen, Model RFLANGEC, chrome plated ABS flange.
The lights will be provided with a clear lens.
These lights will be activated with the side warning switch.
The lights may be load managed when the parking brake is applied.
0564655 Lights, Rear Zone Lower, Wln M6*C
LED, Clear Lens, For Tail Lt Housing
REAR ZONE LOWER LIGHTING
There shall be two (2) Whelen®, Model M6*C, LED flashing warning lights located at the rear of
the apparatus.
The driver's side rear light to be amber
The passenger's side rear light to be red
Both lights will include a lens that is clear.
There will be a switch located in the cab on the switch panel to control the lights.
0594099 Light, Rear Zone Upper, Wln L31H*F
LED Beacon, Red DS/Amber PS
REAR OF HOSE BED WARNING LIGHTS
There will be two (2) Whelen, Model L31H*F, LED warning beacons provided at the rear of the
truck, located one (1) each side.
The color of the driver side LED light will be red and the passenger side LED light will be amber.
The dome colors will be both domes clear.
There will be a switch located in the cab on the switch panel to control the beacons.
0006551 Not Required, Lights, Rear Upper
Zone Blocking
0016621 Mtg, Rear Warn Lts, LS Compt Top,
RS S/S low mount
The left side rear warning light will be mounted on top of the compartmentation with all wiring
totally enclosed. The clearance/marker light will be mounted to the side of the compartment ridge.
The right side rear warning light will be mounted on a low mount stainless steel bracket with all
wiring totally enclosed. This brackets will also support the clearance/marker light.
The rear deck lights will be mounted on the beavertail flange to keep the overall height as low as
possible.
0791457 Light, Traffic Directing, Wln TANF85,
45.12" Long LED
TRAFFIC DIRECTING LIGHT
There will be one (1) Whelen®, Model TANF85, 45.12" long x 2.37" high x 2.37" deep, amber
LED traffic directing light installed at the rear of the apparatus.
The Whelen, Model TACTL5, control head will be included with this installation.
The controller will be energized when the battery switch is on.
The auxiliary flash not activated.
0529858 Location, Traf Dir Lt, Recessed
Within Trdplt Step
This traffic directing light will be recessed within a treadplate step at the rear of the apparatus.
0530282 Location, Traf Dir Lt Controller,
Overhead Switch Panel DS Right
End
The traffic directing light control head will be located in the driver side overhead switch panel in
the right panel position.
0589985 Inverter, Vanner Bravo QBC10-
12/120-60G,1050W - Derated to
800W Loc Feature
INVERTER / BATTERY CHARGER
A Vanner Model Bravo 1050 model QBC10-12/120-60G inverter will be provided. The inverter will
provide a de-rated 800 continuous watts of 120 VAC modified sine wave power to operate lights,
tools and appliances. The inverter will be connected to the batteries through proper fusing and
also to shoreline AC power.
An auto transfer switch will be included allowing AC loads connected to the inverter to be
powered from the battery whenever shoreline AC power is not available. If shoreline AC power is
available, the AC loads connected to the inverter will be powered through the shoreline
connection.
The inverter will be mounted in the LS3 (as high as possible against front bulkhead wall) and
have adequate ventilation. A master on/off switch will be provided on the pump panel.
0015829 Circuit Breaker Panel with Inverter CIRCUIT BREAKER PANEL
A circuit breaker panel will be installed in the LS3 (as high as possible against front bulkhead
wall). A directory for each breaker will be provided adjacent to the circuit breaker panel.
Identification of circuits will be done in a durable manner that provides years of service.
58377Bid #:
PROPOSAL NO. 81217-180036622 Receptacle, 20A 120V 3-Pr 3-Wr SB
Dup, GFCI, Wtrprf
120 VOLT RECEPTACLE
There will be two (2), 20 amp 120 volt AC three (3) wire straight blade duplex GFCI receptacle(s)
with waterproof flip up cover(s) installed DS and PS pump panel. The NEMA configuration for the
receptacles will be 5-20R.
The receptacle(s) will be powered from the on board generator.
There will be a label installed near the receptacle(s) that state the following:
Line Voltage
Current Ratting (amps)
Phase
Frequency
Power Source
0519934 Not Required, Brand, Hydraulic Tool
System
0649753 Not Required, PTO Driven Hydraulic
Tool System
0007150 Bag of Nuts and Bolts
LOOSE EQUIPMENT
The following equipment will be furnished with the completed unit:
- One (1) bag of chrome, stainless steel, or cadmium plated screws, nuts, bolts and washers, as
used in the construction of the unit.
0602516 NFPA Required Loose Equipment,
Pumper, NFPA 2016, Provided by
Fire Department
NFPA REQUIRED LOOSE EQUIPMENT PROVIDED BY FIRE DEPARTMENT
The following loose equipment as outlined in NFPA 1901, 2016 edition, section 5.9.3 and 5.9.4
will be provided by the fire department.
800 ft (60 m) of 2.50" (65 mm) or larger fire hose.
400 ft (120 m) of 1.50" (38 mm), 1.75" (45 mm), or 2.00" (52 mm) fire hose.
One (1) handline nozzle, 200 gpm (750 L/min) minimum.
Two (2) handline nozzles, 95 gpm (360 L/min) minimum.
One (1) smoothbore of combination nozzle with 2.50" shutoff that flows a minimum of 250 gpm.
One (1) SCBA complying with NFPA 1981 for each assigned seating position, but not fewer than
four (4), mounted in brackets fastened to the apparatus or stored in containers supplied by the
SCBA manufacturer.
One (1) spare SCBA cylinder for each SCBA carried, each mounted in a bracket fastened to the
apparatus or stored in a specially designed storage space(s).
One (1) first aid kit.
Four (4) combination spanner wrenches.
Two (2) hydrant wrenches.
One (1) double female 2.50" (65 mm) adapter with National Hose threads.
One (1) double male 2.50" (65 mm) adapter with National Hose threads.
One (1) rubber mallet, for use on suction hose connections.
Two (2) salvage covers each a minimum size of 12 ft x 14 ft (3.7 m x 4.3 m).
One (1) traffic vest for each seating position, each vest to comply with ANSI/ISEA 207, Standard
for High Visibility Public Safety Vests, and have a five-point breakaway feature that includes two
(2) at the shoulders, two (2) at the sides, and one (1) at the front.
Five (5) fluorescent orange traffic cones not less than 28.00" (711 mm) in height, each equipped
with a 6.00" (152 mm) retro-reflective white band no more than 4.00" (152 mm) from the top of
the cone, and an additional 4.00" (102 mm) retro-reflective white band 2.00" (51 mm) below the
6.00" (152 mm) band.
Five (5) illuminated warning devices such as highway flares, unless the five (5) fluorescent
orange traffic cones have illuminating capabilities.
One (1) automatic external defibrillator (AED).
Four (4) ladder belts meeting the requirements of NFPA 1983, Standard on Fire Service Life
Safety Rope and System Components (if equipped with an aerial device).
If the supply hose carried does not use sexless couplings, an additional double female adapter
and double male adapter, sized to fit the supply hose carried, will be carried mounted in brackets
fastened to the apparatus.
If none of the pump intakes are valved, a hose appliance that is equipped with one or more gated
intakes with female swivel connection(s) compatible with the supply hose used on one side and a
swivel connection with pump intake threads on the other side will be carried. Any intake
connection larger than 3.00" (75 mm) will include a pressure relief device that meets the
requirements of 16.6.6.
If the apparatus does not have a 2.50" National Hose (NH) intake, an adapter from 2.50" NH
female to a pump intake will be carried, mounted in a bracket fastened to the apparatus if not
already mounted directly to the intake.
If the supply hose carried has other than 2.50" National Hose (NH) threads, adapters will be
carried to allow feeding the supply hose from a 2.50" NH thread male discharge and to allow the
hose to connect to a 2.50" NH female intake, mounted in brackets fastened to the apparatus if not
already mounted directly to the discharge or intake.
0602407 Soft Suction Hose, Provided by Fire
Department, Pumper NFPA 2016
Classification
SOFT SUCTION HOSE PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, section 5.8.2.1 requires a minimum of 20' of suction hose or 15' of
supply hose will be carried.
Hose is not on the apparatus as manufactured. The fire department will provide suction or supply
hose.
0027023 No Strainer Required
59377Bid #:
PROPOSAL NO. 81217-180602538 Extinguisher, Dry Chemical, Pumper
NFPA 2016 Class, Provided by Fire
Department
DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, section 5.9.4 requires one (1) approved dry chemical portable fire
extinguisher with a minimum 80-B:C rating mounted in a bracket fastened to the apparatus.
The extinguisher is not on the apparatus as manufactured. The fire department will provide and
mount the extinguisher.
0602360 Extinguisher, 2.5 Gal. Pressurized
Water, Pumper NFPA 2016,Provided
by Fire Dept
WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, section 5.9.4 requires one (1) 2.5 gallon or larger water extinguisher
mounted in a bracket fastened to the apparatus.
The extinguisher is not on the apparatus as manufactured. The fire department will provide and
mount the extinguisher.
0602679 Axe, Flathead, Pumper NFPA 2016
Classification, Provided by Fire
Department
FLATHEAD AXE PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, Section 5.9.4 requires one (1) flathead axe mounted in a bracket
fastened to the apparatus.
The axe is not on the apparatus as manufactured. The fire department will provide and mount the
axe.
0602667 Axe, Pickhead, Pumper NFPA 2016
Classification, Provided by Fire
Department
PICKHEAD AXE PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, Section 5.9.4 requires one (1) pickhead axe mounted in a bracket
fastened to the apparatus.
The axe is not on the apparatus as manufactured. The fire department will provide and mount the
axe.
60377Bid #:
PROPOSAL NO. 81217-180559683 Paint, Two Tone, Cab, Special Paint
Break at Roof, Custom Cab
PAINT - BODY PAINTED TO MATCH CAB
The exterior custom cab and body painting procedure will consist of a seven (7) step finishing
process as follows:
Manual Surface Preparation - All exposed metal surfaces on the custom cab and body will be
thoroughly cleaned and prepared for painting. Imperfections on the exterior surfaces will be
removed and sanded to a smooth finish. Exterior seams will be sealed before painting. Exterior
surfaces that will not be painted include; chrome plating, polished stainless steel, anodized
aluminum and bright aluminum treadplate.
Chemical Cleaning and Pretreatment - All surfaces will be chemically cleaned to remove dirt, oil,
grease, and metal oxides to ensure the subsequent coatings bond well. The aluminum surfaces
will be properly cleaned and treated using a high pressure, high temperature 4 step Acid Etch
process. The steel and stainless surfaces will be properly cleaned and treated using a high
temperature 3 step process specifically designed for steel or stainless. The chemical treatment
converts the metal surface to a passive condition to help prevent corrosion. A final pure water
rinse will be applied to all metal surfaces.
Surfacer Primer - The Surfacer Primer will be applied to a chemically treated metal surface to
provide a strong corrosion protective basecoat. A minimum thickness of 2 mils of Surfacer Primer
is applied to surfaces that require a Critical aesthetic finish. The Surfacer Primer is a two-
component high solids urethane that has excellent sanding properties and an extra smooth finish
when sanded.
Finish Sanding - The Surfacer Primer will be sanded with a fine grit abrasive to achieve an ultra-
smooth finish. This sanding process is critical to produce the smooth mirror like finish in the
topcoat.
Sealer Primer - The Sealer Primer is applied prior to the Basecoat in all areas that have not been
previously primed with the Surfacer Primer. The Sealer Primer is a two-component high solids
urethane that goes on smooth and provides excellent gloss hold out when topcoated.
Basecoat Paint - Two coats of a high performance, two component high solids polyurethane
basecoat will be applied. The Basecoat will be applied to a thickness that will achieve the proper
color match. The Basecoat will be used in conjunction with a urethane clear coat to provide
protection from the environment.
Clear Coat - Two (2) coats of Clear Coat will be applied over the Basecoat color. The Clear Coat
is a two-component high solids urethane that provides superior gloss and durability to the exterior
surfaces. Lap style and roll-up doors will be Clear Coated to match the body. Paint warranty for
the roll-up doors will be provided by the roll-up door manufacture.
Each batch of basecoat color is checked for a proper match before painting of the cab and the
body. After the cab and body are painted, the color is verified again to make sure that it matches
the color standard. Electronic color measuring equipment is used to compare the color sample to
the color standard entered into the computer. Color specifications are used to determine the color
match. A Delta E reading is used to determine a good color match within each family color.
All removable items such as brackets, compartment doors, door hinges, and trim will be removed
and separately if required, to ensure paint behind all mounted items. Body assemblies that
cannot be finish painted after assembly will be finish painted before assembly.
Pierce Manufacturing paint finish quality levels for critical areas of the apparatus (cab front and
sides, body sides and doors, and boom lettering panels) meet or exceed the Cadillac/General
Motors GMW15777 global paint requirements. Orange peel levels meet or exceed the #6
A.C.T.standard in critical areas. These requirements are met in order for the exterior paint finish
to be considered acceptable. The Pierce Manufacturing written paint standards will be available
upon request.
The cab will be two-tone, with the roof section painted PPG White 2185 (Pierce White #252) and
lower section of the cab and body painted PPG Red 911659 (Pierce Red #90).
PAINT - ENVIRONMENTAL IMPACT
Contractor will meet or exceed all current State regulations concerning paint operations. Pollution
control will include measures to protect the atmosphere, water and soil. Controls will include the
following conditions:
Topcoats and primers will be chrome and lead free.
Metal treatment chemicals will be chrome free. The wastewater generated in the metal treatment
process will be treated on-site to remove any other heavy metals.
Particulate emission collection from sanding operations will have a 99.99% efficiency factor.
Particulate emissions from painting operations will be collected by a dry filter or water wash
process. If the dry filter is used, it will have an efficiency rating of 98.00%. Water wash systems
will be 99.97% efficient
Water from water wash booths will be reused. Solids will be removed on a continual basis to keep
the water clean.
Paint wastes are disposed of in an environmentally safe manner.
Empty metal paint containers will be to recover the metal.
Solvents used in clean-up operations will be recycled on-site or sent off-site for distillation and
returned for reuse.
Additionally, the finished apparatus will not be manufactured with or contain products that have
ozone depleting substances. Contractor will, upon demand, present evidence that the
manufacturing facility meets the above conditions and that it is in compliance with his State EPA
rules and regulations.
61377Bid #:
PROPOSAL NO. 81217-180646901 Paint Chassis Frame Assy, With
Liner, E-Coat, Standard
PAINT CHASSIS FRAME ASSEMBLY
The chassis frame assembly will be finished with primer and gloss paint to match the lower job
color before the installation of the cab and body, and before installation of the engine and
transmission assembly, air brake lines, electrical wire harnesses, etc.
Components that are included with the chassis frame assembly that will be painted are:
Frame rails
Frame liners
Cross members
Axles
Suspensions
Steering gear
Battery boxes
Bumper extension weldment
Frame extensions
Body mounting angles
Rear Body support substructure (front and rear)
Pump house substructure
Air tanks
Steel fuel tank
Castings
Individual piece parts used in chassis and body assembly
Components treated with epoxy E-coat protection prior to paint:
Two (2) C-channel frame rails
Two (2) frame liners
The E-coat process will meet the technical properties shown.
0693797 No Paint Required, Aluminum Front
Wheels
0693792 No Paint Required, Aluminum Rear
Wheels
0007230 Compartment, Painted, Spatter Gray
COMPARTMENT INTERIOR PAINT
The interior of all compartments will be painted with a gray spatter finish for ease of cleaning and
to make it easier to touch up scratches and nicks.
0544177 Reflective Band, 2"- 6"
REFLECTIVE STRIPES
Two (2) reflective stripes will be provided across the front of the vehicle and along the sides of the
body. The reflective band will consist of a 2.00" white stripe at the top with a 1.00" gap, then a
6.00" white stripe on the bottom.
0007356 Reflective across Cab Face
The reflective band provided on the cab face will be at the headlight level.
0536954 Stripe, Chevron, Rear, Diamond
Grade, Pumper
REAR CHEVRON STRIPING
There will be alternating chevron striping located on the rear-facing vertical surface of the
apparatus. The rear surface, excluding the rear compartment door, will be covered.
The colors will be red and fluorescent yellow green diamond grade.
Each stripe will be 6.00" in width.
This will meet the requirements of the current edition of NFPA 1901, which states that 50% of the
rear surface will be covered with chevron striping.
0027341 Jog, In Reflective Stripe, Single or
Multiple
JOG(S) IN REFLECTIVE BAND
The reflective band located on each side of the apparatus body will contain one (1) jog(s) and will
be angled at approximately a 45 degrees when installed.
0017359 Stripe, Black Outline, Vinyl on
Reflective Band
REFLECTIVE STRIPE OUTLINE
A black outline will be applied on the top and the bottom of the reflective band. There will be two
(2) set of outline stripes required.
62377Bid #:
PROPOSAL NO. 81217-180544967 Stripe, Chevron, Diamond Grade,
Rear Compartment, Lap, Pumpers
CHEVRON STRIPING ON REAR LAP COMPARTMENT
There will be alternating chevron striping located on the rear lap door.
The colors will be red and fluorescent yellow green diamond grade.
Each stripe will be 6.00" in width.
0065687 Stripe, Reflective, Cab Doors Interior
CAB DOOR REFLECTIVE STRIPE
A 6.00" x 16.00" black reflective stripe will be provided across the interior of each cab door. The
stripe will be located approximately 1.00" up from the bottom, on the door panel.
This stripe will meet the NFPA 1901 requirement.
0594559 Lettering Specifications, (Sign Gold
Process)
LETTERING
The lettering will be 22 karat gold vinyl.
0685911 Lettering, Sign Gold, 4.00", (1-20)
LETTERING
One (1) to twenty (20) Sign Gold lettering, 4.00" high, with outline and shade will be provided.
0685830 Lettering, Sign Gold, 2.00", (21-40)
LETTERING
Twenty-one (21) to forty (40) Sign Gold lettering, 2.00" high, with outline and shade will be
provided.
0685849 Lettering, Sign Gold, 3.00", Each
LETTERING
There will be sign gold lettering, 3.00" high, with outline and shade provided. There will be 27
letters provided.
0686002 Lettering, Reflective, 8.00", Each
LETTERING
There will be reflective lettering, 8.00" high, with outline and shade provided. There will be four
(4) letters provided.
0686013 Lettering, Reflective, 6.00", Each
LETTERING
There will be reflective lettering, 6.00" high, with outline and shade provided. There will be two
(2) letters provided.
0686042 Lettering, Reflective, 2.00", Each
LETTERING
There will be reflective lettering, 2.00" high, with outline provided. There will be 12
letters provided.
0683998 Lettering, Vinyl, 16.00", Each
LETTERING
There will be non-reflective vinyl lettering, 16.00" high, with no outline or shade provided. There
will be six (6) letters provided.
0645076 Plate, Painted Alum. for
Lettering/Numerals
PAINTED PLATE(S) FOR LETTERING/NUMERALS
There will be one (1) painted aluminum plate(s) provided for department lettering. They will be
mounted Located on the D/S hosebed cover only. and will be 24"H x 88"W plate painted job color
white. in size.
0684201 Emblem, Maltese Cross, Sign Gold,
9"-11", Pair
EMBLEMS
There will be one (1) pair of maltese crosses, comprised of sign gold material, provided and
installed (1) each on the driver and officer doors.
0666414 Emblem, Freedom Flag, Each
EMBLEM
There will be two (2) emblem(s), approximately 9.00" - 11.00" wide in size, installed cab sides
behind the crew cab doors as high as possible. The emblem will feature a "Flying American Flag"
and an "Eagle Head".
63377Bid #:
PROPOSAL NO. 81217-180529225 Manuals, Two (2) CD, Fire Apparatus
Parts, Custom Chassis
FIRE APPARATUS PARTS CD MANUAL
There will be two (2) custom parts manuals for the complete fire apparatus provided in CD format
with the completed unit.
The manuals will contain the following:
Job number
Part numbers with full descriptions
Table of contents
Parts section sorted in functional groups reflecting a major system, component, or assembly
Parts section sorted in alphabetical order
Instructions on how to locate parts
The manuals will be specifically written for the chassis and body model being purchased. It will
not be a generic manual for a multitude of different chassis and bodies.
SERVICE PARTS INTERNET SITE
The service parts information included in these manuals are also available on the factory website.
The website offers additional functions and features not contained in this manual, such as digital
photographs and line drawings of select items. The website also features electronic search tools
to assist in locating parts quickly.
0531636 Manual, Two (2) CD, Chassis
Service, Custom
CHASSIS SERVICE CD MANUALS
There will be two (2) CD format chassis service manuals containing parts and service information
on major components provided with the completed unit.
The manual will contain the following sections:
Job number
Table of contents
Troubleshooting
Front Axle/Suspension
Brakes
EngineTires
Wheels
Cab
Electrical, DC
Air Systems
Plumbing
Appendix
The manual will be specifically written for the chassis model being purchased. It will not be a
generic manual for a multitude of different chassis and bodies.
0531638 Manual, Two (2) CD, Chassis
Operation, Custom
CHASSIS OPERATION CD MANUALS
There will be two (2) CD format chassis operation manuals provided.
0030008 Warranty, Basic, 1 Year, Apparatus,
WA0008
ONE (1) YEAR MATERIAL AND WORKMANSHIP
A Pierce basic apparatus limited warranty certificate, WA0008, is included with this proposal.
0696698 Warranty, Engine, Cummins, 5 Year,
WA0181
ENGINE WARRANTY
A Cummins five (5) year limited engine warranty will be provided. A limited warranty certificate,
WA0181, is included with this proposal.
0684953 Warranty, Steering Gear, Sheppard
M110, 3 Year WA0201
STEERING GEAR WARRANTY
A Sheppard three (3) year limited steering gear warranty shall be provided. A copy of the
warranty certificate shall be submitted with the bid package.
0596017 Warranty, Frame, 50 Year, Custom
Chassis, WA0013
FIFTY (50) YEAR STRUCTURAL INTEGRITY
The Pierce custom chassis frame limited warranty certificate, WA0013, is included with this
proposal.
0595698 Warranty, Axle, 3 Year, TAK-4,
WA0050
FRONT AXLE THREE (3) YEAR MATERIAL AND WORKMANSHIP WARRANTY
The Pierce TAK-4 suspension limited warranty certificate, WA0050, is included with this proposal.
0777368 Warranty, Axle, 2 Year, Meritor,
General Service, WA0328
REAR AXLE TWO (2) YEAR MATERIAL AND WORKMANSHIP WARRANTY
A Meritor axle limited warranty certificate, WA0046, is included with this proposal.
0652758 Warranty, ABS Brake System, 3
Year, Meritor Wabco, WA0232
ABS BRAKE SYSTEM THREE (3) YEAR MATERIAL AND WORKMANSHIP
WARRANTY
A Meritor Wabco™ABS brake system limited warranty certificate, WA0232, is included with this
proposal.
0019914 Warranty, Structure, 10 Year, Custom
Cab, WA0012
TEN (10) YEAR STRUCTURAL INTEGRITY
The Pierce custom cab limited warranty certificate, WA0012, is included with this proposal.
64377Bid #:
PROPOSAL NO. 81217-180595813 Warranty, Paint, 10 Year, Cab, Pro-
Rate, WA0055
TEN (10) YEAR PRO-RATED PAINT AND CORROSION
A Pierce cab limited pro-rated paint warranty certificate, WA0055, is included with this proposal.
0524627 Warranty, Electronics, 5 Year, MUX,
WA0014
FIVE (5) YEAR MATERIAL AND WORKMANSHIP
The Pierce Command Zone electronics limited warranty certificate, WA0014, is included with this
proposal.
0695416 Warranty, Pierce Camera System,
WA0188
CAMERA SYSTEM WARRANTY
A Pierce fifty four (54) monthwarranty will be provided for the camera system.
0647720 Warranty, Pierce LED Strip Lights,
WA0203
COMPARTMENT LIGHT WARRANTY
The Pierce 12 volt DC LED strip lights limited warranty certificate, WA0203, is included with this
proposal.
0046369 Warranty, 5-year EVS Transmission,
Standard Custom, WA0187
TRANSMISSION WARRANTY
The transmission will have a five (5) year/unlimited mileage warranty covering 100 percent
parts and labor. The warranty will be provided by Allison Transmission.
Note: The transmission cooler is not covered under any extended warranty you may be getting on
your Allison Transmission. Please review your Allison Transmission warranty for coverage
limitations.
0685945 Warranty, Transmission Cooler,
WA0216
TRANSMISSION COOLER WARRANTY
The transmission cooler will carry a five (5) year parts and labor warranty (exclusive to the
transmission cooler). In addition, a collateral damage warranty will also be in effect for the first
three (3) years of the warranty coverage and will not exceed $10,000 per occurrence. A copy of
the warranty certificate will be submitted with the bid package.
0688798 Warranty, Water Tank, Lifetime, UPF,
Poly Tank, WA0195
WATER TANK WARRANTY
A UPF poly water tank limited warranty certificate, WA0195, is included with this proposal.
0596025 Warranty, Structure, 10 Year, Body,
WA0009
TEN (10) YEAR STRUCTURAL INTEGRITY
The Pierce apparatus body limited warranty certificate, WA0009, is included with this proposal.
0693127 Warranty, Gortite, Roll-up Door, 6
Year, WA0190
ROLL UP DOOR MATERIAL AND WORKMANSHIP WARRANTY
A Gortite roll-up door limited warranty will be provided. The mechanical components of the roll-up
door will be warranted against defects in material and workmanship for the lifetime of the vehicle.
A six (6) year limited warranty will be provided on painted and satin roll up doors.
The limited warranty certificate, WA0190, is included with this proposal.
0063510 Warranty, Pump, Waterous, 5 Year
Parts, WA0225
PUMP WARRANTY
A Waterous pump limited warranty certificate, WA0225, is included with this proposal.
0648675 Warranty, 10 Year S/S Pumbing,
WA0035
TEN (10) YEAR PUMP PLUMBING WARRANTY
The Pierce apparatus plumbing limited warranty certificate, WA0035, is included with this
proposal.
0641372 Warranty, Foam System, Not
Available
0595820 Warranty, Paint, 10 Year, Body, Pro-
Rate, WA0057
TEN (10) YEAR PRO-RATED PAINT AND CORROSION
A Pierce body limited pro-rated paint warranty certificate, WA0057, is included with this proposal.
0595412 Warranty, Graphics Lamination, 1
Year, Apparatus, WA0168
ONE (1) YEAR MATERIAL AND WORKMANSHIP
The Pierce graphics fading and deterioration limited warranty limited warranty certificate,
WA0168, is included with this proposal.
0683627 Certification, Vehicle Stability,
CD0156
VEHICLE STABILITY CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the apparatus complies with
NFPA 1901, current edition, section 4.13, Vehicle Stability. The certification will be provided at
the time of bid.
65377Bid #:
PROPOSAL NO. 81217-180777618 Certification, Engine Installation,
Saber FR/Enf, Cummins L9,
2017,CD0155/CD0158
ENGINE INSTALLATION CERTIFICATION
The fire apparatus manufacturer will provide a certification, along with a letter from the engine
manufacturer stating they approve of the engine installation in the bidder's chassis. The
certification will be provided at the time of bid.
0686786 Certification, Power Steering,
CD0098
POWER STEERING CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the power steering system as
installed meets the requirements of the component supplier. The certification will be provided at
the time of bid.
0631980 Certification, Cab Integrity, Saber
FR/Enforcer, CD0130
CAB INTEGRITY CERTIFICATION
The fire apparatus manufacturer will provide a cab crash test certification with this proposal. The
certification will state that a specimen representing the substantial structural configuration of the
cab has been tested and certified by an independent third party test facility. Testing events will be
documented with photographs, real-time and high-speed video, vehicle accelerometers, cart
accelerometers, and a laser speed trap. The fire apparatus manufacturer will provide a state
licensed professional engineer to witness and certify all testing events. Testing will meet or
exceed the requirements below:
- European Occupant Protection Standard ECE Regulation No.29.
- SAE J2422 Cab Roof Strength Evaluation - Quasi-Static Loading Heavy Trucks.
- SAE J2420 COE Frontal Strength Evaluation - Dynamic Loading Heavy Trucks.
- Roof Crush
The cab will be subjected to a roof crush force of 22,500 lb. This value meets the ECE 29 criteria,
and is equivalent to the front axle rating up to a maximum of ten (10) metric tons.
- Side Impact
The same cab will be subjected to dynamic preload where a 13,275-lb moving barrier is slammed
into the side of the cab at 5.50 mph, striking with an impact of 13,000 ft-lb of force. This test is
part of the SAE J2422 test procedure and more closely represents the forces a cab will see in a
rollover incident.
- Frontal Impact
The same cab will withstand a frontal impact of 32,600 ft-lb of force using a moving barrier in
accordance with SAE J2420.
- Additional Frontal Impact
The same cab will withstand a frontal impact of 65,200 ft-lb of force using a moving barrier.
(Twice the force required by SAE J2420)
The same cab will withstand all tests without any measurable intrusion into the survival space of
the occupant area.
0631973 Certification, Cab Door Durability,
Saber FR/Enforcer, CD0137
CAB DOOR DURABILITY CERTIFICATION
Robust cab doors help protect occupants. Cab doors will survive a 200,000 cycle door slam test
where the slamming force exceeds 20 G's of deceleration. The bidder will certify that the sample
doors similar to those provided on the apparatus have been tested and have met these criteria
without structural damage, latch malfunction, or significant component wear.
0631978 Certification, Windshield Wiper
Durability, Saber FR/Enforcer,
CD0132
WINDSHIELD WIPER DURABILITY CERTIFICATION
Visibility during inclement weather is essential to safe apparatus performance. Windshield wipers
will survive a 3 million cycle durability test in accordance with section 6.2 of SAE J198 Windshield
Wiper Systems - Trucks, Buses and Multipurpose Vehicles. The bidder will certify that the wiper
system design has been tested and that the wiper system has met these criteria.
0631974 Certification, Electric Window
Durability, Saber FR/Enforcer,
CD0133
ELECTRIC WINDOW DURABILITY CERTIFICATION
Cab window roll-up systems can cause maintenance problems if not designed for long service
life. The window regulator design will complete 30,000 complete up-down cycles and still function
normally when finished. The bidder will certify that sample doors and windows similar to those
provided on the apparatus have been tested and have met these criteria without malfunction or
significant component wear.
0631977 Certification, Seat Belt Anchors and
Mounting, Saber FR/Enforcer,
CD0134
SEAT BELT ANCHOR STRENGTH
Seat belt attachment strength is regulated by Federal Motor Vehicle Safety Standards and should
be validated through testing. Each seat belt anchor design will withstand 3000 lb of pull on both
the lap and shoulder belt in accordance with FMVSS 571.210 Seat Belt Assembly Anchorages.
The bidder will certify that each anchor design was pull tested to the required force and met the
appropriate criteria.
SEAT MOUNTING STRENGTH
Seat attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be
validated through testing. Each seat mounting design will be tested to withstand 20 G's of force in
accordance with FMVSS 571.207 Seating Systems. The bidder will certify, at time of delivery, that
each seat mount and cab structure design was pull tested to the required force and met the
appropriate criteria.
66377Bid #:
PROPOSAL NO. 81217-180631976 Certification, Cab Heater and
Defroster, Saber FR/Enforcer,
CD0131
CAB DEFROSTER CERTIFICATION
Visibility during inclement weather is essential to safe apparatus performance. The defroster
system will clear the required windshield zones in accordance with SAE J381 Windshield
Defrosting Systems Test Procedure And Performance Requirements - Trucks, Buses, And
Multipurpose Vehicles.The bidder will certify that the defrost system design has been tested in a
cold chamber and passes the SAE J381 criteria.
CAB HEATER CERTIFICATION
Good cab heat performance and regulation provides a more effective working environment for
personnel, whether in-transit, or at a scene. The cab heaters will warm the cab 77 degrees
Fahrenheit from a cold-soak, within 30 minutes when tested using the coolant supply methods
found in SAE J381. The bidder will certify, at time of delivery, that a substantially similar cab has
been tested and has met these criteria.
0631971 Certification, Cab Air Conditioning
Performance, Saber FR/Enforcer,
CD0135
CAB AIR CONDITIONING PERFORMANCE CERTIFICATION
Good cab air conditioning temperature and air flow performance keeps occupants comfortable,
reduces humidity, and provides a climate for recuperation while at the scene. The cab air
conditioning system will cool the cab from a heat-soaked condition at 100 degrees Fahrenheit to
an average of 78 degrees Fahrenheit in 30 minutes. The bidder will certify that a substantially
similar cab has been tested and has met these criteria.
0545073 Amp Draw Report, NFPA Current
Edition
AMP DRAW REPORT
The bidder will provide, at the time of bid and delivery, an itemized print out of the expected amp
draw of the entire vehicle's electrical system.
The manufacturer of the apparatus will provide the following:
Documentation of the electrical system performance tests.
A written load analysis, which will include the following:
The nameplate rating of the alternator.
The alternator rating under the conditions specified per:
Applicable NFPA 1901 or 1906 (Current Edition).
The minimum continuous load of each component that is specified per:
Applicable NFPA 1901 or 1906 (Current Edition).
Additional loads that, when added to the minimum continuous load, determine the total connected
load.
Each individual intermittent load.
All of the above listed items will be provided by the bidder per the applicable NFPA 1901 or 1906
(Current Edition).
0002758 Amp Draw, NFPA/ULC Radio
Allowance
0799248 Appleton/Florida BTO
0000018 PUMPER, 2ND GEN
0000012 PIERCE CHASSIS
0004713 ENGINE, OTHER
0046395 EVS 3000 Series TRANSMISSION
0020011 WATEROUS PUMP
0020009 POLY TANK
0028048 FOAM SYSTEM
0020006 SIDE CONTROL
0020008 ELKHART VALVES
0020015 ABS SYSTEM
0658751 Manufacturing Attribute
67377Bid #:
PROPOSAL NO. 81217-1868377Bid #:
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if any)
or to the warranties (if any) made by any manufacturer (other than Pierce) of any part,
component, attachment or accessory that is incorporated into or attached to the vehicle.
2/8/2010 WA0012
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This warranty applies only to the cab tubular support and
mounting structures and other structural components of the
cab of the vehicle model, as identified in the Pierce
specifications for the Fire and Rescue Apparatus.
This warranty does not apply to damage caused by corrosion.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
Fire and Rescue Apparatus
Coverage:
Ten (10) Year Structural Integrity
Custom Cab
Ten (10) Years
- or -
100,000 Miles
Warranty Period
Ends After:
The date of the original purchase invoice (issued when the
product ships from the factory).Warranty Begins:
The Pierce Custom Cab shall be free from structural failures
caused by defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY
OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce
specifically disclaims any liability for property or personal injury damages, penalties,
damages for lost profits or revenues, loss of vehicles or products or any associated
equipment, cost of substitute vehicles or products, down-time, delay damages, any other
types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.PROPOSAL NO. 81217-18
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if any)
or to the warranties (if any) made by any manufacturer (other than Pierce) of any part,
component, attachment or accessory that is incorporated into or attached to the vehicle.
2/8/2010 WA0008
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
No specific exclusions apply
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
Fire and Rescue Apparatus
Coverage:
One (1) Year Material and Workmanship
Basic Apparatus
Twelve (12) months.Warranty Period
Ends After:
The date the apparatus is placed in service, or 60 days from
the original buyer invoice date, whichever comes first.Warranty Begins:
Portions of the apparatus manufactured by Pierce shall be
free from defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY
OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce
specifically disclaims any liability for property or personal injury damages, penalties,
damages for lost profits or revenues, loss of vehicles or products or any associated
equipment, cost of substitute vehicles or products, down-time, delay damages, any other
types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.PROPOSAL NO. 81217-18
NEW PRODUCT WARRANTY
PARTICIPATING OEM SALES
DISTRIBUTOR SALES
LIMITED WARRANTY ON NEW ALLISON AUTOMATIC TRANSMISSIONS
USED IN EMERGENCY VEHICLE APPLICATIONS
Allison Transmission will provide for repairs or replacement, at its option, during the warranty period of each new Allison transmission
listed below that is installed in an Emergency Vehicle in accordance with the following terms, conditions, and limitations.
WHAT IS COVERED
WARRANTY APPLIES — This warranty is for new Allison transmission models listed below installed in an Emergency Vehicle and
is provided to the original and any subsequent owner(s) of the vehicle during the warranty period.
REPAIRS COVERED — The warranty covers repairs or replacement, at Allison Transmission’s option, to correct any transmission
malfunction resulting from defects in material or workmanship occurring during the warranty period. Needed repairs or replacements
will be performed using the method Allison Transmission determines most appropriate under the circumstances.
TOWING — Towing is covered to the nearest Allison Transmission Distributor or authorized Dealer only when necessary to prevent
further damage to your transmission.
PAYMENT TERMS — Warranty repairs, including parts and labor, will be covered per the schedule shown in the chart contained in
section “APPLICABLE MODELS, WARRANTY LIMITATIONS, AND ADJUSTMENT SCHEDULE.”
OBTAINING REPAIRS — To obtain warranty repairs, take the vehicle to any Allison Transmission Distributor or authorized Dealer
within a reasonable amount of time and request the needed repairs. A reasonable amount of time must be allowed for the Distributor or
Dealer to perform necessary repairs.
TRANSMISSION REMOVAL AND REINSTALLATION — Labor costs for the removal and re-installation of the transmission,
when necessary to make a warranty repair, are covered by this warranty.
WARRANTY PERIOD — The warranty period for all coverages shall begin on the date the transmission is delivered to the first retail
purchaser, with the following exception:
Demonstration Service - A transmission in a new truck or bus may be demonstrated to a total of 5000 miles (8000 kilometers).
If the vehicle is within this limit when sold to a retail purchaser, the warranty start date is the date of purchase. Normal warranty
services are applicable to the demonstrating Dealer. Should the truck or bus be sold to a retail purchaser after these limits are
reached, the warranty period will begin on the date the vehicle was first placed in demonstration service and the purchaser will be
entitled to the remaining warranty.
APPLICABLE MODELS, WARRANTY LIMITATIONS, AND ADJUSTMENT SCHEDULE
WARRANTY LIMITATIONS
(Whichever occurs first)
ADJUSTMENT CHARGE TO BE
PAID BY THE CUSTOMER APPLICABLE
MODELS
Months Transmission Miles
Or Kilometers Parts Labor
MT, MD
3000, 3200, 3500, 3700 0–24 No Limit No Charge No Charge
HT with Hydraulic Controls 0–24 No Limit No Charge No Charge
AT, 1000 Series, 2000 Series,
2400 Series 0–36 No Limit No Charge No Charge
HT with Electronic Controls 0–60 No Limit No Charge No Charge
HD
1000 EVS, 2100 EVS, 2200 EVS
2350 EVS, 2500 EVS, 2550 EVS,
3000 EVS, 3500 EVS, 4000,
4000 EVS, 4500, 4500 EVS, 4700,
4700 EVS, 4800, 4800 EVS
0–60 No Limit No Charge No Charge
Page 1 of 2 PROPOSAL NO. 81217-18
WHAT IS NOT COVERED
DAMAGE DUE TO ACCIDENT, MISUSE, or ALTERATION — Defects and damage caused as the result of any of the following
are not covered:
— Flood, collision, fire, theft, freezing, vandalism, riot, explosion, or objects striking the vehicle;
— Misuse of the vehicle;
— Installation into unapproved applications and installations;
— Alterations or modification of the transmission or the vehicle, and
— Damage resulting from improper storage (refer to long-term storage procedure outlined in the applicable Allison Service Manual)
— Anything other than defects in Allison Transmission material or workmanship
NOTE: This warranty is void on transmissions used in vehicles currently or previously titled as salvaged, scrapped, junked, or totaled.
CHASSIS, BODY, and COMPONENTS — The chassis and body company (assemblers) and other component and equipment manufacturers
are solely responsible for warranties on the chassis, body, component(s), and equipment they provide. Any transmission repair caused by an
alteration(s) made to the Allison transmission or the vehicle which allows the transmission to be installed or operated outside of the limits
defined in the appropriate Allison Installation Guideline is solely the responsibility of the entity making the alteration(s).
DAMAGE CAUSED by LACK of MAINTENANCE or by the USE of TRANSMISSION FLUIDS NOT RECOMMENDED in
the OPERATOR’S MANUAL — Defects and damage caused by any of the following are not covered:
— Failure to follow the recommendations of the maintenance schedule intervals applicable to the transmission;
— Failure to use transmission fluids or maintain transmission fluid levels recommended in the Operator’s Manual.
MAINTENANCE — Normal maintenance (such as replacement of filters, screens, and transmission fluid) is not covered and is the
owner’s responsibility.
REPAIRS by UNAUTHORIZED DEALERS — Defects and damage caused by a service outlet that is not an authorized Allison
Transmission Distributor or Dealer are not covered.
USE of OTHER THAN GENUINE ALLISON TRANSMISSION PARTS — Defects and damage caused by the use of parts that are
not genuine Allison Transmission parts are not covered.
EXTRA EXPENSES — Economic loss and extra expenses are not covered. Examples include but are not limited to: loss of vehicle
use; inconvenience; storage; payment for loss of time or pay; vehicle rental expense; lodging; meals; or other travel costs.
“DENIED PARTY” OWNERSHIP — Warranty repair parts and labor costs are not reimbursed to any participating or non-participating
OEMs, dealers or distributors who perform warranty work for, or on behalf of, end users identified by the United States as being a “denied
party” or who are citizens of sanctioned or embargoed countries as defined by the U.S. Department of Treasury Office of Foreign Assets
Control. Furthermore, warranty reimbursements are not guaranteed if the reimbursement would be contrary to any United States export control
laws or regulations as defined by the U.S. Department of Commerce, the U.S. Department of State, or the U.S. Department of Treasury.
OTHER TERMS APPLICABLE TO CONSUMERS AS DEFINED by the MAGNUSON-MOSS WARRANTY ACT
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Allison Transmission does not authorize any person to create for it any other obligation or liability in connection with these transmissions.
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE APPLICABLE TO
THESE TRANSMISSIONS IS LIMITED IN DURATION TO THE DURATION OF THIS WRITTEN WARRANTY.
PERFORMANCE OF REPAIRS AND NEEDED ADJUSTMENTS IS THE EXCLUSIVE REMEDY UNDER THIS WRITTEN
WARRANTY OR ANY IMPLIED WARRANTY. ALLISON TRANSMISSION SHALL NOT BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES (SUCH AS, BUT NOT LIMITED TO, LOST WAGES OR VEHICLE RENTAL EXPENSES)
RESULTING FROM BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.**
** Some states do not allow limitations on how long an implied warranty will last or the exclusion or limitation of incidental or
consequential damages, so the above limitations or exclusions may not apply to you.
OTHER TERMS APPLICABLE TO OTHER END-USERS
THIS WARRANTY IS THE ONLY WARRANTY APPLICABLE TO THE ALLISON TRANSMISSION MODELS LISTED
ABOVE AND IS EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ALLISON
TRANSMISSION DOES NOT AUTHORIZE ANY PERSON TO CREATE FOR IT ANY OTHER OBLIGATION OR LIABILITY
IN CONNECTION WITH SUCH TRANSMISSIONS. ALLISON TRANSMISSION SHALL NOT BE LIABLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES RESULTING FROM BREACH OF THIS WARRANTY OR ANY IMPLIED WARRANTY.
QUESTIONS
If you have any questions regarding this warranty or the performance of warranty obligations, you may contact any Allison Transmission
Distributor or Dealer or write to:
Allison Transmission, Inc.
P.O. Box 894
Indianapolis, IN 46206-0894
Attention: Warranty Administration PF-9
Form SE0616EN (201009)
Page 2 of 2 PROPOSAL NO. 81217-18
Waterous Five-Year Limited Warranty WATEROUS warrants, to the original Buyer only, that products manufactured by WATEROUS will be free from defects in material and workmanship under normal use and service for a period of five (5) years from the date the product is first placed in service, or five and one-half (5-1/2) years from the date of shipment by WATEROUS, whichever period shall be the first to expire; provided the Buyer notifies WATEROUS, in writing, of the defect in said product within the warranty period, and said product is found by WATEROUS to be nonconforming with the aforesaid warranty. When required in writing by WATEROUS, defective products must be promptly returned by Buyer to WATEROUS at WATEROUS' plant at South St. Paul, Minnesota, or at such other place as may be specified by WATEROUS, with transportation and other charges prepaid. A Returned Material Authorization (RMA) is required for all products and parts and may be requested by phone, fax, email, or mail. The aforesaid warranty excludes any responsibility or liability of WATEROUS for: (a) damages or defects due to accident, abuse, misuse, abnormal operating conditions, negligence, accidental causes, use in non-firefighting applications, or improper maintenance, or attributable to written specifications or instructions furnished by Buyer; (b) defects in products manufactured by others and furnished by WATEROUS hereunder, it being understood and agreed by the parties that the only warranty provided for such products shall be the warranty provided by the manufacturer thereof which, if assignable, WATEROUS will assign to Buyer, if requested by Buyer; (c) any product or part, altered, modified, serviced or repaired other than by WATEROUS, without its prior written consent; (d) the cost of dismantling, removing, transporting, storing, or insuring the defective product or part and the cost of reinstallation; and (e) normal wear items (packing, strainers, filters, light bulbs, anodes, intake screens, mechanical seals, etc.). ALL OTHER WARRANTIES ARE EXCLUDED, WHETHER EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY, OR ANY OTHER CAUSE OF ACTION, SHALL WATEROUS BE LIABLE FOR ANY PUNITIVE, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR FOR PERSONAL INJURY OR PROPERTY DAMAGES. The exclusive remedy of Buyer and the sole liability of WATEROUS, whether based on contract, warranty, tort or any other basis of recovery whatsoever, is expressly limited at the election of WATEROUS to: (a) the replacement at the agreed point of delivery of any product or part, which upon inspection by WATEROUS or its duly authorized representative, is found not to conform to the limited warranty set forth above, or (b) the repair of such product or part, or (c) the refund or crediting to Buyer of the net sales price of the defective product or part. BUYER'S REMEDIES CONTAINED HEREIN ARE EXCLUSIVE OF ANY OTHER REMEDY OTHERWISE AVAILABLE TO BUYER. F‐2113 (07/17/12) Waterous Company 125 Hardman Avenue South South St. Paul, MN 55075 USA www.waterousco.com PROPOSAL NO. 81217-18
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if any)
or to the warranties (if any) made by any manufacturer (other than Pierce) of any part,
component, attachment or accessory that is incorporated into or attached to the vehicle.
2/8/2010 WA0014
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This limited warranty applies to all of the control modules for
the Command Zone system, including the full color graphic
displays. Related wire harnesses, cables and connectors are
not covered under this limited warranty and are instead
covered under the Pierce One Year Basic Apparatus Limited
Warranty.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
Fire and Rescue Apparatus
Coverage:
Five (5) Year Material and Workmanship
Command Zone Electronics
Five (5) YearsWarranty Period
Ends After:
The date of the original purchase invoice (issued when the
product ships from the factory).Warranty Begins:
Command Zone control modules shall be free from failures
caused by defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY
OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce
specifically disclaims any liability for property or personal injury damages, penalties,
damages for lost profits or revenues, loss of vehicles or products or any associated
equipment, cost of substitute vehicles or products, down-time, delay damages, any other
types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.PROPOSAL NO. 81217-18
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if any)
or to the warranties (if any) made by any manufacturer (other than Pierce) of any part,
component, attachment or accessory that is incorporated into or attached to the vehicle.
2/22/2010 WA0168
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This warranty does not cover damage from lack of
maintenance and cleaning (proper cleaning and maintenance
procedures are detailed in the Pierce operation and
maintenance manual).
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
Fire and Rescue Apparatus
Coverage:
One (1) Year Material and Workmanship
Graphics Fading and Deterioration
One (1) YearWarranty Period
Ends After:
The date the apparatus is placed in service, or 60 days from
the original buyer invoice date, whichever comes first.Warranty Begins:
Each graphic lamination shall be free from defects in material,
workmanship, fading, and deterioration.
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY
OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce
specifically disclaims any liability for property or personal injury damages, penalties,
damages for lost profits or revenues, loss of vehicles or products or any associated
equipment, cost of substitute vehicles or products, down-time, delay damages, any other
types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.PROPOSAL NO. 81217-18
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This limited warranty excludes brake pads, brake rotors, seal
boots and shock absorbers.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the
foregoing, Pierce specifically disclaims any liability for property or personal injury
damages, penalties, damages for lost profits or revenues, loss of vehicles or products or
any associated equipment, cost of substitute vehicles or products, down-time, delay
damages, any other types of economic loss, or for any claims by any third party for any
such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
Three (3) Years
-or-
30,000 Miles
Warranty Period
Ends After:
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if
any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any
part, component, attachment or accessory that is incorporated into or attached to the
vehicle.12/16/2013 WA0050
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES
ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
Fire and Rescue Apparatus
Coverage:
Three (3) Year Material and Workmanship
TAK-4 Independent Front Suspension
Limited WarrantyLimited WarrantyLimited WarrantyLimited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
The TAK-4 Front Independent Suspension and Steering
Gears shall be free from defects in material and
workmanship.
1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
The date of the original purchase invoice (issued when the
product ships from the factory).Warranty Begins: PROPOSAL NO. 81217-18
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY
OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce
specifically disclaims any liability for property or personal injury damages, penalties,
damages for lost profits or revenues, loss of vehicles or products or any associated
equipment, cost of substitute vehicles or products, down-time, delay damages, any other
types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
Fire and Rescue Apparatus
Coverage:
Ten (10) Year Pro-Rated Paint and Corrosion
Cab
Ten (10) YearsWarranty Period
Ends After:
The date of the original purchase invoice (issued when the
product ships from the factory).Warranty Begins:
Exterior surfaces of the cab painted by Pierce shall be free
from blistering, peeling, corrosion or any other adhesion
defect caused by defective manufacturing methods or paint
material selection.
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if any)
or to the warranties (if any) made by any manufacturer (other than Pierce) of any part,
component, attachment or accessory that is incorporated into or attached to the vehicle.
2/8/2010 WA0055
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This limited warranty is applicable to the vehicle in the
following percentage costs of warranty repair, if any:
Topcoat Durability & Appearance: Gloss, Color Retention &
Cracking
0-72 months 100%
73-96 months 50%
97-120 months 25%
Integrity of Coating System: Adhesion, Blistering/Bubbling
0-36 months 100%
37-84 months 50%
85-120 months 25%
Corrosion: Dissimilar Metal and Crevice
0-36 months 100%
37-48 months 50%
49-72 months 25%
73-120 months 10%
Corrosion Perforation
0-120 months 100%
This limited warranty applies only to exterior paint. Paint on
the vehicle's interior is warranted only under the Pierce Basic
One Year Limited Warranty.
Items not covered by this warranty include:
(a) Damage from lack of maintenance and cleaning (proper
cleaning and maintenance procedures are detailed in the
Pierce operation and maintenance manual).
(b) UV paint fade.
(c) Any cab not manufactured by Pierce.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
PROPOSAL NO. 81217-18
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if any)
or to the warranties (if any) made by any manufacturer (other than Pierce) of any part,
component, attachment or accessory that is incorporated into or attached to the vehicle.
2/8/2010 WA0057
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This limited warranty is applicable to the vehicle in the
following percentage costs of warranty repair, if any:
Topcoat Durability & Appearance: Gloss, Color Retention &
Cracking
0-72 months 100%
73-96 months 50%
97-120 months 25%
Integrity of Coating System: Adhesion, Blistering/Bubbling
0-36 months 100%
37-84 months 50%
85-120 months 25%
Corrosion: Dissimilar Metal and Crevice
0-36 months 100%
37-48 months 50%
49-72 months 25%
73-120 months 10%
Corrosion Perforation
0-120 months 100%
This limited warranty applies only to exterior paint. Paint on
the vehicle's interior is warranted only under the Pierce Basic
One Year Limited Warranty.
Items not covered by this warranty include:
(a) Damage from lack of maintenance and cleaning (proper
cleaning and maintenance procedures are detailed in the
Pierce operation and maintenance manual).
(b) UV paint fade.
(c) Any cab not manufactured by Pierce.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
Fire and Rescue Apparatus
Coverage:
Ten (10) Year Pro-Rated Paint and Corrosion
Custom Body
Ten (10) YearsWarranty Period
Ends After:
The date of the original purchase invoice (issued when the
product ships from the factory).Warranty Begins:
Exterior surfaces of the body shall be free from blistering,
peeling, corrosion or any other adhesion defect caused by
defective manufacturing methods or paint material selection.
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY
OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce
specifically disclaims any liability for property or personal injury damages, penalties,
damages for lost profits or revenues, loss of vehicles or products or any associated
equipment, cost of substitute vehicles or products, down-time, delay damages, any other
types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.PROPOSAL NO. 81217-18
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if any)
or to the warranties (if any) made by any manufacturer (other than Pierce) of any part,
component, attachment or accessory that is incorporated into or attached to the vehicle.
2/8/2010 WA0013
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This warranty does not apply to damage caused by corrosion.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
Fire and Rescue Apparatus
Coverage:
Lifetime Fifty (50) Year Structural Integrity
Custom Chassis Frame
Fifty (50) Years
(Expected Life of Apparatus)
Warranty Period
Ends After:
The date of the original purchase invoice (issued when the
product ships from the factory).Warranty Begins:
Custom chassis frame rail manufactured by Pierce shall be
free from defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY
OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce
specifically disclaims any liability for property or personal injury damages, penalties,
damages for lost profits or revenues, loss of vehicles or products or any associated
equipment, cost of substitute vehicles or products, down-time, delay damages, any other
types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.PROPOSAL NO. 81217-18
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if any)
or to the warranties (if any) made by any manufacturer (other than Pierce) of any part,
component, attachment or accessory that is incorporated into or attached to the vehicle.
2/8/2010 WA0009
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This warranty applies only to the body tubular support and
mounting structures and other structural components of the
body of the vehicle model, as identified in the Pierce
specifications for the Fire and Rescue Apparatus.
This warranty does not apply to damage caused by corrosion.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
Fire and Rescue Apparatus
Coverage:
Ten (10) Year Structural Integrity
Apparatus Body
Ten (10) Years
- or -
100,000 Miles
Warranty Period
Ends After:
The date of the original purchase invoice (issued when the
product ships from the factory).Warranty Begins:
The apparatus body shall be free from structural failures
caused by defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY
OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce
specifically disclaims any liability for property or personal injury damages, penalties,
damages for lost profits or revenues, loss of vehicles or products or any associated
equipment, cost of substitute vehicles or products, down-time, delay damages, any other
types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.PROPOSAL NO. 81217-18
Fire and Rescue Apparatus
Coverage:
Ten (10) Year Material and Workmanship
Pierce 12V LED Strip Light
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
This limited warranty covers repairs to correct any defect
related to materials or workmanship of the Pierce 12V LED
strip lights installed on the apparatus occuring during the
warranty period.
1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
The date of the original purchase invoice (issued when the
product ships from the factory).Warranty Begins:
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This limited warranty does not apply to related wire
harnesses, cables, and connectors, which are covered by the
Pierce one (1) year basic apparatus limited warranty.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY
OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce
specifically disclaims any liability for property or personal injury damages, penalties,
damages for lost profits or revenues, loss of vehicles or products or any associated
equipment, cost of substitute vehicles or products, down-time, delay damages, any other
types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
Ten (10) YearWarranty Period
Ends After:
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if any)
or to the warranties (if any) made by any manufacturer (other than Pierce) of any part,
component, attachment or accessory that is incorporated into or attached to the vehicle.
7/5/2011 WA0203
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.PROPOSAL NO. 81217-18
Warranty Begins:
Stainless steel piping shall be free from structural failures
caused by defects in material and workmanship, or
perforation caused by corrosion.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
Ten (10) Years
- or -
100,000 Miles
Warranty Period
Ends After:
Fire and Rescue Apparatus
Coverage:
Ten (10) Year Material and Workmanship
Stainless Steel Piping
1. LIMITED WARRANTY
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
The date of the original purchase invoice (issued when the
product ships from the factory).
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
Pierce’s obligation under this warranty is limited to repairing
or replacing without charge, as Pierce may elect, the
stainless steel piping or components which Pierce
determines to have failed due to defective material and
workmanship, or perforation caused by corrosion.
This warranty does not cover the use of fluoroprotein (FP)
type foam. The sodium chloride within FP foam can cause
long-term damage to system components if not thoroughly
flushed immediately after use.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the
foregoing, Pierce specifically disclaims any liability for property or personal injury
damages, penalties, damages for lost profits or revenues, loss of vehicles or products or
any associated equipment, cost of substitute vehicles or products, down-time, delay
damages, any other types of economic loss, or for any claims by any third party for any
such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if
any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any
part, component, attachment or accessory that is incorporated into or attached to the
vehicle.3/22/2012 WA0035
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES
ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.PROPOSAL NO. 81217-18
)LUHDQG5HVFXH$SSDUDWXV
Coverage:
7KUHH<HDU0DWHULDODQG:RUNPDQVKLS
0HULWRU:DEFR$%6%UDNH6\VWHP
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
The Meritor Wabco ABS brake system shall be covered by
Meritor Wabco as indicated in the attached Meritor Wabco
warranty coverage description
/,0,7(':$55$17<
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
The date of the original purchase invoice (issued when the
product ships from the factory).Warranty Begins:
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
Three (3) YearWarranty Period
Ends After:
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
The exclusions listed in the attached Meritor Wabco warranty
description shall apply.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
(;&/86,212)&216(48(17,$/$1',1&,'(17$/'$0$*(6
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the
foregoing, Pierce specifically disclaims any liability for property or personal injury
damages, penalties, damages for lost profits or revenues, loss of vehicles or products or
any associated equipment, cost of substitute vehicles or products, down-time, delay
damages, any other types of economic loss, or for any claims by any third party for any
such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
%8<(5
6(;&/86,9(5(0('<
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if
any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any
part, component, attachment or accessory that is incorporated into or attached to the
vehicle.2/25/2013 WA0232
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES
ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
',6&/$,0(562):$55$17,(6
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.PROPOSAL NO. 81217-18
Warranty
Model Year 2018 VehiclesPROPOSAL NO. 81217-18
SIMPLER IS BETTER
Warranty coverage is essential to protecting your investment. But understanding the
full details of your coverage can be challenging. This straightforward approach allows
you, our valued customer, to better understand how your specific vehicle applications
will be covered in your region. Our component warranty coverage is provided
according to vocation/usage categories listed below.
• Linehaul covers high mileage operation (over 60,000 miles/year) on well
maintained major highways of concrete or asphalt construction.
• General Service covers moderate mileage operations (less than 60,000 miles/year) on
well maintained public roads (less than 10 percent off-road) typically with less than
three (3) stops per mile.
• Heavy Service (Vocational) covers vehicles with more than 10 percent off-road OR
moderate to frequent starts/stops typically with more than three (3) stops per mile.
• Off-Highway Service covers lower mileage operations. Vehicles are not typically
licensed for highway use.
2 PROPOSAL NO. 81217-18
3
Linehaul Service ...............................................................................................4
General Service ................................................................................................4
Heavy Service ..................................................................................................5
Industrial/Off-Highway Service ........................................................................6
Terms and Conditions ......................................................................................7
How to Read Warranty Coverage (Example)
Number of Years Mileage (in thousands)
Unl=Unlimited
P=Parts Only
P&L=Parts & Labor
3 300 P
CONTENTS
PROPOSAL NO. 81217-18
Effective Model Year 2018 Vehicles 5
Heavy Service Vehicles
Meritor WABCO Components1
ABS (Anti-Lock Braking System) Air 3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic 2/200/P&L
Electronic Braking System (EBS) 3/300/P&L
Electronic Stability Control (ESC) 3/300/P&L
Roll Stability Control (RSC) 3/300/P&L
Air Dryers (ALL) 1/100/P&L
Leveling Valves 1/100/P&L
Air Brake Valves 1/100/P&L
Emission Valves (SCR) 2/200/P&L
Clutch Controls 2/200/P&L
Air Compressors (ALL)2 1/100/P&L
OnGuard™ 3/300/P&L
OnGuardACTIVE™ 3/300/P&L
OnLane™ Lane Departure Warning 3/300/P&L
Blind Spot Detection 3/300/P&L
OptiRide™ 2/200/P&L
Trailer Roll Stability Support (RSS) 3/300/P&L
Trailer Control Line Filter3 1/100/P&L
Trailer ABS Valve3 3/300/P&L
1 WABCO and Meritor WABCO branded components.
2 WABCO compressors installed on Cummins, Mercedes, and DDC engines
are not warranted or serviced by Meritor WABCO. Please contact
your respective dealer/distributor of those engines for warranty
and servicing.
3 An extended warranty of 4/400/P will be applied when a Meritor
WABCO Trailer Control Line Filter is used in combination with a Meritor
WABCO Trailer ABS valve.
• Airport Rescue Fire (ARF)
• Airport Shuttle
• Asphalt Truck
• Block Truck
• Bottom Dump Trailer
Combination
• Cementing Vehicle
• City Bus
• Commercial Pick-Up
• Concrete Pumper
• Construction Material Hauler
• Crash Fire Rescue (CFR)
• Mixer
• Demolition
• Drill Rig
• Dump
• Emergency Service
• Equipment Hauling
• Flatbed Trailer Hauler
• Flatbed Truck
• Fracturing Truck
• Front Loader
• Geophysical Exploration
• Hopper Trailer Combinations
• Landscaping Truck
• Liquid Waste Hauler
• Log Hauling
• Lowboy
• Michigan Special Gravel
Trains
• Michigan Special Log Hauler
• Michigan Special Steel Hauler
• Michigan Special Waste
Vehicle
• Municipal Dump
• Newspaper Delivery
• Package Delivery
• Pick-up and Delivery
• Rapid Intervention Vehicle
(RIV)
• Rear Loader
• Recycling Truck
• Residential Pick-Up/Waste
• Rigging Truck
• R o l l - O ff
• Scrap Truck
• Semi-End Dump
• Sewer/Septic Vacuum
• Shuttle Bus
• Side Loader
• Snowplow/Snowblower
• Steel Hauling
• Tanker
• Tank Truck
• Tractors with Pole Trailers
• Tractor/Trailer with Jeeps
• Transfer Dump
• Transfer Vehicle
• Transit Bus
• Trolley
• Utility Truck
• Winch Truck
Heavy Service Typically Is
• On/Off road vocations (10% or more off-road) OR
• Moderate to frequent starts/stops typically more than
three (3) stops per mile
HEAVY SERVICE (VOCATIONAL) WARRANTY INFORMATION
PROPOSAL NO. 81217-18
7
Coverage Exclusions
Product Description
All
The cost of any repairs, replacements or adjustments
to a covered product due to the following: (1) damage to
the product or its component parts caused by incorrect use,
installation, maintenance or repair, including without
limitation (a) improper fit of mating components or
brackets, (b) damaged threads, (c) cut, broken, chafed,
pinched or otherwise damaged wiring (sensors, harnesses
and connectors), (d) damaged sensors from removal when
seized in block, or associated with sensor adjustments/
alignments, and (e) damage resulting from the use or
installation of non-genuine Meritor WABCO components or
materials; (2) damage to the product, its component parts,
or diminished product or component part performance due
to incorrect operation, deviation from approved conditions
or misapplication; (3) any unauthorized disassembly of the
product or its component parts including without limitation
(a) obliterated, defaced or missing WABCO or Meritor
WABCO name plate, serial numbers or label identifying the
device as a Meritor WABCO product or WABCO component,
(b) changes to sealed adjusting screws, and (c) opening or
attempted repair of non-serviceable components;
(4) malfunction of the component due to internal
contamination out of the vehicle system including without
limitation (a) water and other contamination damage that
is due to the use of a non-genuine air dryer cartridge or
(b) valve failures due to contamination in air system, (5)
complaints associated with noise, (6) damage resulting
from corrosion (including oxidation of electrical devices
and connections).
Air Dryers
Mounting brackets (see vehicle OEM). Desiccant
cartridge housing only.
Air System Components
Normal wear items; Gladhand seals, dash valve knobs, valve
actuation handles, treadles, pedals.
ABS, Electronic Stability Control (ESC), Roll Stability
Control (RSC), OptiRide™, OnGuard™ and OnLane™,
collectively “Electronics”
Failure of electronic components due to overvoltage
condition, improper grounding, electrostatic discharge
(ESD), improper shielding, electromagnetic interference
(EMI), or other wiring or installation issues.
Malfunctions and failure codes caused by other electronic
subsystem failures (data bus, engine, transmission,
dashboard, etc.)
Hydraulic Components
For certain components, brake fluid DOT3 or DOT4 is used
as the operating medium. Use of any other fluid will void
all warranties associated with that component. For
hydraulic braking applications the brake fluid is considered
a maintenance item. Maintenance intervals are listed
in TB-1367.
Coverage Limitations
Product Description
All
Any claim beyond 60 days from date of repair will not be
accepted or honored under this warranty program.
Products purchased on an incomplete vehicle (glider) are
limited to one year, 1/Unl/P.
For vehicles that operate full- or part-time outside of the
United States and Canada, a 1-Year/Unlimited Miles parts
only (1/Unl/P) will apply.
TOOLBOX™ Software
Proper diagnostics of Meritor WABCO Electronics may
require the latest version of TOOLBOX™. Additional labor
due to use of an outdated version of TOOLBOX™. TOOLBOX™
software, and/or the time to purchase or install latest version
of TOOLBOX™ are not covered under product warranty.
TERMS AND CONDITIONS
PROPOSAL NO. 81217-18
8
TERMS AND CONDITIONS
(1) What is Covered by this Commercial Warranty?
Meritor WABCO Vehicle Control Systems warrants to the owner
(“Owner”) that the components listed in this publication, which
have been installed by an Original Equipment Manufacturer
(“OEM”) as original equipment will be free from defects in material
and workmanship. This warranty coverage begins from the original
in-service date to the limits provided and runs concurrently with
any warranties provided by OEMs and/or any service contracts
that cover the components listed in this publication, if any. If
the components listed in this publication are covered by an OEM
warranty and/or service contract, then the OEM’s warranty and/
or service contract shall supersede Meritor WABCO’s warranty and
Owner shall comply with all OEM’s warranty and/or service contract
requirements for claims under such OEM’s warranty and/or service
contract until those agreements expire. Once those agreements
expire and provided the Meritor WABCO warranty has not expired
under the terms stated above, the Meritor WABCO warranty would
be in effect until its expiration date.
Warranty coverage ends at the expiration of the applicable time
period from the date of vehicle purchase by the first Owner, or, the
applicable mileage limitation, whichever occurs first. Duration of
coverage varies by component and vocation as detailed previously
in this publication. Some components are warranted for parts
only and the Owner must pay any labor costs associated with the
repair or replacement of the component. Other components are
warranted for both parts and reasonable labor to repair or replace
the subject component. Additional diagnostic time due to use of
an outdated version of TOOLBOX™, time to purchase or install
latest version of TOOLBOX™ are the responsibility of the authorized
Meritor WABCO service location and are not covered under product
warranty. Components installed as replacements under this
warranty are warranted only for the remainder of the original
period of time or mileage under the original warranty.
(2) Designation of Vocational Use Required.
To obtain warranty coverage, each Owner must notify Meritor
WABCO through the OEM new truck and/or trailer dealer of the
intended vocational use of the vehicle into which the Meritor WABCO
components have been incorporated prior to the vehicle in-service
date. This notification may be accomplished by registering the
vehicle through your OEM new truck and/or trailer dealer or with
Meritor WABCO directly. Failure to notify Meritor WABCO of (I) the
intended vocational use of the vehicle or (II) a change in vocational
use from that which was originally designated, will result in the
application of a one year, unlimited mileage, parts only warranty
(1/Unl/P) from the initial in-service date.
A second Owner and each subsequent Owner must also notify
Meritor WABCO as to the intended vocational use of the vehicle.
This notification can be sent directly to Meritor WABCO or through
the OEM new truck and/or trailer dealer. The duration and mileage
coverage of this warranty cannot exceed the coverage extended to
the first Owner after his or her initial designation of vocational use.
Coverage under Meritor WABCO’s warranty requires that the
application of products be properly approved pursuant to OEM
and Meritor WABCO, approvals.
(3) What is the Cost of this Warranty?
There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty?
In addition to the items listed on page 7, this warranty does not
cover normal wear and tear, or service items; nor does it cover a
component that fails, malfunctions or is damaged as a result of
(a) improper handling, storage, installation, adjustment, repair
or modification including the use of unauthorized attachments
or changes or modification in the vehicle’s configuration, usage,
or vocation from that which was originally approved by Meritor
WABCO, (b) accident, fire or other casualty, natural disaster, road
debris, negligence, misuse, abuse, or improper use (including
loading beyond the specified maximum vehicle weight or altering
engine power settings to exceed the brake system capacity), or (c)
improper or insufficient maintenance (including deviation from
maintenance intervals, approved lubricants, or lube levels). This
warranty does not cover any component or part that is not sold by
Meritor WABCO.
(5) Remedy.
The exclusive remedy under this warranty shall be the repair or
replacement of the defective component at Meritor WABCO’s
option. Meritor WABCO reserves the right to require that all
applicable covered components are available and/or returned to
Meritor WABCO for review and evaluation.
(6) DISCLAIMER OF WARRANTY.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES
OR CONDITIONS, EXPRESS, IMPLIED OR STATUTORY INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
PARTICULAR PURPOSE. SOME STATES LIMIT OR DO NOT ALLOW THE
DISCLAIMER OF IMPLIED OR OTHER WARRANTIES, SO THE ABOVE
LIMITATION OR EXCLUSION MAY NOT APPLY TO THE EXTENT SUCH
STATE’S LAW IS APPLICABLE TO THESE TERMS.
(7) LIMITATION OF REMEDIES.
IN NO EVENT SHALL MERITOR WABCO BE LIABLE FOR SPECIAL, INCI-
DENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES OF ANY KIND OR
UNDER ANY LEGAL THEORY, INCLUDING, BUT NOT LIMITED TO, TOW-
ING, DOWNTIME, LOST PRODUCTIVITY, CARGO DAMAGE, TAXES, LOST
PROFITS, COSTS OF PROCUREMENT OF A SUBSTITUTE COMPONENT
OR ANY OTHER LOSSES OR COSTS RESULTING FROM A COVERED
COMPONENT. SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF SPECIAL, INCIDENTAL, INDIRECT OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT
APPLY TO THE EXTENT SUCH STATE’S LAW IS APPLICABLE TO THESE
TERMS.
(8) TIME LIMIT ON COMMENCING LEGAL ACTION.
ANY LEGAL ACTION OR CLAIM ARISING FROM OR RELATED TO THIS
WARRANTY, IN CONTRACT OR OTHERWISE, MUST BE COMMENCED
WITHIN ONE YEAR FROM THE ACCRUAL OF THAT CAUSE OF ACTION,
OR BE BARRED FOREVER.
(9) To Obtain Service.
If the Owner discovers within the applicable coverage period a
defect in material or workmanship, the Owner must promptly give
notice to either Meritor WABCO or the dealer from which the
vehicle was purchased. To obtain service, the vehicle must be
taken to any participating OEM new truck and/or trailer dealer or
authorized Meritor WABCO service location. The dealer will inspect
the vehicle and contact Meritor WABCO for an evaluation of the
claim. When authorized by Meritor WABCO, the dealer will repair
or replace during the term of this warranty any defective Meritor
WABCO component covered by this warranty.
(10) Entire Agreement.
This is the entire agreement between Meritor WABCO and the
Owner about warranty and no Meritor, Meritor WABCO employee,
or dealer is authorized to make any additional warranty on behalf
of Meritor WABCO unless in writing and signed by an authorized
representative of Meritor WABCO.PROPOSAL NO. 81217-18
meritorwabco.com
©2017 Meritor WABCO Vehicle Control Systems
Meritor WABCO Vehicle Control Systems is a
joint venture of Meritor™ and WABCO
For more information on
Meritor WABCO Warranty, call
our OnTrac Customer Service team
at 866-OnTrac1 (866-668-7221)
or visit meritorwabco.com.
Litho in USA. Revised 06/17.
SP-1375 (47865/11900)
Meritor WABCO Vehicle Control Systems
2135 West Maple Road, Troy, Michigan 48084, USA
Phone: 866-ONTRAC1 (866-668-7221) Fax: 248-435-8002PROPOSAL NO. 81217-18
PROPOSAL NO. 81217-18
PROPOSAL NO. 81217-18
PROPOSAL NO. 81217-18
PROPOSAL NO. 81217-18
Warranty Begins:
The transmission cooler shall be free from component or
structural failures caused by defects in material and/or
workmanship. Collateral damage up to $10,000 per
occurrence is available for the first three (3) years.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
Five (5) Years on Oil Cooler and three (3) years on collateral
damage coverage
Warranty Period
Ends After:
Fire and Rescue Apparatus
Coverage:
Five (5) Year Material and Workmanship - Transmission Oil Cooler
Three (3) Year Collateral Damage Coverage
1. LIMITED WARRANTY
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
The date of delivery to the first retail purchaser.
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This warranty does not cover repair due to accidents,
misuse, and excessive vibration, flying debris, storage
damage (freezing), negligence or modification. This warranty
is void if any modification or repairs are performed without
authorization. This also voids any future warranty.
This warranty does not cover cost of maintenance or repairs
due to lack of required maintenance services as
recommended. Performance of the required maintenance
and use of proper fluids are the responsibility of the owner.
Towing is covered to the nearest distributor or authorized
dealer only when necessary to prevent further damage to
your transmission.
Labor costs for the removal and reinstallation of goods may
be covered when necessary to make repairs. Please contact
your OEM for authorization.
Replacement of cooler during the warranty period is limited
to 100% of reasonable labor costs up to a maximum of $700
to remove, replace, or repair the oil cooler.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the
foregoing, Pierce specifically disclaims any liability for property or personal injury
damages, penalties, damages for lost profits or revenues, loss of vehicles or products or
any associated equipment, cost of substitute vehicles or products, down-time, delay
damages, any other types of economic loss, or for any claims by any third party for any
such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if
any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any
part, component, attachment or accessory that is incorporated into or attached to the
vehicle.2/22/2012 WA0216
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES
ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.PROPOSAL NO. 81217-18
United Plastic Fabricating, Inc. (hereinafter called “UPF”) warrants each
POLY-TANK®, Booster/Foam Tank POLYSIDE® Wetside Tank, Integrator
Tank/Body, ELLIPSE™ Elliptical Tank, Ellip-T-Tank Tank and DEFENDER™
Skid Tank to be free from defects in material and workmanship for the service
life of the original vehicle (vehicle must be actively used in an emergency re-
sponse for fire suppression). All UPF Tanks must be installed and operated in
accordance with the UPF Installation and Operating Guidelines. Failure to do
so can void the warranty.
Every UPF Tank is inspected and tested before leaving our facility. Should
your UPF Tank require service, please notify UPF via email, fax, in writing or
by calling UPF at 1-978-975-4520. Please provide the serial number, a de-
scription of the service request, the location along with the phone number and
name of the contact person. Our goal is to have scheduled work completed
within a reasonable time period.
Under a valid warranty claim, UPF will cover the cost to repair the UPF Tank
including the customary and reasonable costs to make the tank accessible
such as the removal and reinstallation of the tank if authorized in advance
(pre-approved) by UPF. The warranty will not cover tanks that have been im-
properly installed, operated, misused, abused, or modified from its intended
or designed use. Serial number must not have been altered, defaced or re-
moved. Tanks that are not stored or installed properly which results in the tank
suffering UV damage will not be covered by this agreement.
Should UPF determine that the service claim is valid under this warranty for a
tank located outside of the United States and Canada, UPF will assume the
costs for labor and material for the warranty repair as described above plus
all travel costs to the U.S. port of embarkation. Costs for airline travel outside
of the U.S. and Canada will not be the responsibility of UPF.
In the event the tank shall become stationed in an area of the world that is
considered to be a war zone or where unsafe conditions exist for the safe
passage of United States Nationals, as reported by the United States Depart-
ment of State, (http://www.state.gov), and a request to perform service or
warranty repairs, UPF reserves the right to refuse to honor such requests. It
is the purchaser’s responsibility to relocate the tank to an area where such
repairs can be performed without undue risk to UPF employees or their des-
ignee. UPF will make every reasonable effort to support our products though
alternative means.
For Ellipse™ elliptical tanks, a separate five year warranty provided by the
subcontractor is applied to the sub-frames, chute linings (rubber isolation
strips) and metal components. The stainless steel wrap provided by UPF
shall be warranted by the subcontractor performing the wrap installation in
accordance with their warranty in place at the time of the installation. UPF
will not be liable for any warranty costs associated with the wrap, sub-frames,
chute linings (rubber isolation strips) and metal components but will assist
with all claims on behalf of its customer.
For PolySide® wetsided tanks and Integrator™ Tank/Body units, all polypro-
pylene components related to the tank shall carry the standard UPF lifetime FOR: POLY-TANK®, POLYSIDE®, INTEGRATOR™, ELLIPSE™, ELLIP-T-TANK™ & DEFENDER™WARRANTYUNITED PLASTIC FABRICATING, INC. LIFETIME SERVICE WARRANTY
Continued on back
Effective 1 August, 2009
PROPOSAL NO. 81217-18
service warranty. Other polypropylene components, including but not limited
to compartments, wheel wells, fenders and other body related components
shall be warranted by UPF for a period of ten years. The warranty for the
PolySide® and Integrator™ units excludes paint or hardware, which shall be
covered by the manufacturer of the paint/hardware.
All UPF tanks 50 gallons or less utilized for non-fire applications and installed
on specialty vehicles such as ATVs, trailers, boats, etc. are covered under a
separate warranty policy available from UPF. Further, UPF Protector™ foam
and water trailers are warranted under a separate warranty policy available
from UPF.
This UPF warranty is transferable within the United States only with prior writ-
ten approval by UPF (except an original apparatus manufacturer may assign
this warranty to the first titled owner/lessee of the apparatus).
UPF will NOT reimburse any unnecessary work and/or work that has
not been pre-approved. Any and all third party charges must be pre-
authorized and approved in writing by UPF prior to commencing the
work. Any unauthorized third party repairs, alterations, actions or modi-
fications will not be covered and can void the warranty. UPF will be the
sole determining authority as to whether a service claim will be valid
and covered under this warranty.
In no event will UPF be liable for an amount in excess of the purchase price
of the booster/foam tank at the time of manufacture or for any loss or dam-
age, whether direct, indirect, incidental, consequential, or otherwise arising
out of failure of its product. Loss of contents (water, foam, etc.) shall not be
the responsibility of UPF. Further, UPF is not responsible for costs associated
with service repairs to chassis, sub-frames, bodies, valves, dumps, hoses,
pressure vacuum vents, and other components (i.e. liquid level transducers,
etc.). Further, UPF will not cover the cost for travel of the vehicle to and from
a repair facility.
This warranty contains the entire warranty. It is the sole warranty and price
agreements or representation, whether oral or written, are either merged
herein or expressly cancelled. UPF neither assumes, nor authorizes any per-
son supposing to act on its behalf to change, nor assume for it, any warranty
or liability concerning its product.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state. Some states do not allow exclusion or
limitation or incidental or consequential damage, so the above limitation or
exclusion may not apply to you. Since some states do not allow limitations on
the length of an implied warranty, the above limitation may not apply to you.
THERE ARE NO WARRANTIES, EXPRESSED OR IMPLIED, WHICH EX-
TEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. THERE IS
NO EXPRESS OR IMPLIED WARRANTY OF MERCHANTABILITY OR A
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. ADDITION-
ALLY, THIS WARRANTY IS IN LIEU OF ALL OTHER OBLIGATION OR
LIABILITIES ON THE PART OF UPF.FOR: POLY-TANK®, POLYSIDE®, INTEGRATOR™, ELLIPSE™, ELLIP-T-TANK™ & DEFENDER™WARRANTYUNITED PLASTIC FABRICATING, INC. POLY-TANK®,& POLYSIDE® are registered trademarks of UPF, Inc. INTEGRATOR™, ELLIPSE™,
ELLIP-T-TANK™ & DEFENDER™ are trademarks of UPF, Inc. © 08/01/09 UPF, Inc. Printed in the USAPROPOSAL NO. 81217-18
2 6 0 0 A M E R I C A N D R I V E • A P P L E T O N , W I 5 4 9 1 2 -2 0 1 7 • 9 2 0 -832-3 000
P I E R C E M A N U F A C T U R I N G I N C .
B U L L E T I N
TO: All Dealer Service Representatives
From: Kevin Hanegraaf
DATE: January 4, 2010
RE: UPF Tank Warranty Policy – Truck in Accident
Service Topic #292
To keep the UPF tank warranty valid on trucks that have been involved in a vehicular
accident, it is UPF’s policy that the customer must remove the tank from the truck and
send it back to one of UPF’s facilities for inspection. In the event that this does not take
place, the warranty will be considered null and void.
The customer must remove and send the tank back to UPF for inspection in order to
maintain the original warranty coverage, at which time it will be:
- Filled with water
- Visually inspected
- Ultraviolet spark tested on articulating test stand in the dark
- Recommendation for repairs if necessary provided by UPF
- Fully evaluated and repaired by UPF
If your customer chooses to leave the tank on the truck and wants a technician to
inspect and/or repair the tank in the field, then the warranty is no longer in effect.
This direction is upheld by UPF because the technician cannot inspect the entire tank
when it is still installed on the truck.
Note: This memo is intended to relay the information Pierce has received
on UPF’s tank warranty for trucks that are in a vehicular accident. In the
event of an actual claim, we direct you to consult with UPF’s service
Manager Maura Watts (800-638-8265 x253)
PROPOSAL NO. 81217-18
A & A Manufacturing Co., Inc. 2300 S. Calhoun Road · New Berlin, WI 53151 · Phone (262) 786-1500 · Fax (262) 786-3280
Pierce Warranty Statement for Gortite Roll Up Doors Rev 2/24/2011
All mechanical components of the door shall be warranted to be free from defects in materials and
workmanship for the lifetime of the vehicle. All parts covered under this warranty shall be to the original
owner.
A&A manufacturing warrants that painted doors shall be free of blistering, peeling, bubbling, or any other
adhesion defect caused by defective manufacturing methods or paint material selection. The time period for the
coverage shall be 6 years from date of door shipment to Pierce. Satin anodized finish doors shall be warranted
for 6 years against corrosion defects from date of door shipment to Pierce. Replacement of decals/Scotchlite is
not covered.
The maximum amount A&A will reimburse for labor is $60.00 per hour and the maximum amount of time
allowed for repair is as follows:
Door 1.0 Hr.
Slat Replacement 1.0 Hr.
Pennant Plate Replacement 1.0 Hr.
Roller Replacement .5 Hr.
Seal Replacement .5 Hr.
Switch/Magnet Replacement 1.0 Hr.
Travel Time 4.0 Hr.
PROPOSAL NO. 81217-18
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited
warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for
such vehicle, and not to other warranties made by Pierce in a separate document (if any)
or to the warranties (if any) made by any manufacturer (other than Pierce) of any part,
component, attachment or accessory that is incorporated into or attached to the vehicle.
1/11/2011 WA0188
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES
ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is
normal to the particular model. Normal service means service which does not subject the
product to stresses or impacts greater than normally result from careful use. If the Buyer
discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days
after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER
OR TO ANY OTHER PERSON OR ENTITY.
This limited warranty does not apply to related wire
harnesses, cables, and connectors, which are covered by the
Pierce one (1) year basic apparatus limited warranty.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides
the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce
which, in the sole judgment of Pierce, adversely affects the performance, stability or
purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts,
components, attachments and accessories, Pierce shall assign to Buyer the applicable
warranties, if any, made by the respective manufacturers thereof;
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever
as to:
Fire and Rescue Apparatus
Coverage:
54 Months Material and Workmanship
Camera System
Fifty - Four (54) monthsWarranty Period
Ends After:
The date of delivery.Warranty Begins:
This limited warranty covers repairs to correct any defect
related to materials or workmanship of the Sharpvision
camera system installed on the apparatus occuring during the
warranty period.
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies
into finishing products or vehicles unless the assembly is performed by Pierce.
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY
OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce
specifically disclaims any liability for property or personal injury damages, penalties,
damages for lost profits or revenues, loss of vehicles or products or any associated
equipment, cost of substitute vehicles or products, down-time, delay damages, any other
types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1,
and shall make the product available for inspection by Pierce or its designated agent. At
the request of Pierce, any allegedly defective product shall be returned to Pierce by
Buyer for examination and/or repair. Buyer shall be responsible for the cost of such
transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense)
any nonconforming or defective parts. Repair or replacement shall be made only by a
facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE
EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.PROPOSAL NO. 81217-18
Cummins Warranty
Worldwide
Fire Apparatus/Crash Trucks
PROPOSAL NO. 81217-18
Coverage
Products Warranted
This Warranty applies to new diesel Engines sold by
Cummins and delivered to the first user on or after
April 1,2007,that are used in fire apparatus truck and
crash truck*applications Worldwide.
Base Engine Warranty
The Base Engine Warranty covers any failures of the
Engine which result,under normal use and service,
from a defect in material or factory workmanship
(Warrantable Failure).This Coverage begins with the
sale of the Engine by Cummins and ends five years or
100,000 miles (160,935 kilometers),whichever occurs
first,after the date of delivery of the Engine to the first
user.
Engine aftertreatment components included in the
Cummins Critical Parts List (CPL)and marked with a
Cummins part number are covered under Base Engine
Warranty.
Additional Coverage is outlined in the Emission
Warranty section.
These Warranties are made to all Owners in the
chain of distribution and Coverage continues to all
subsequent Owners until the end of the periods of
Coverage.
Cummins
Responsibilities
Cummins will pay for all parts and labor needed to
repair the damage to the Engine resulting from a
Warrantable Failure.
Cummins will pay for the lubricating oil,antifreeze,
filter elements,belts,hoses and other maintenance
items that are not reusable due to the Warrantable
Failure.
Cummins will pay for reasonable labor costs for
Engine removal and reinstallation when necessary to
repair a Warrantable Failure.
Cummins will pay reasonable costs for towing a
vehicle disabled by a Warrantable Failure to the
nearest authorized repair location.In lieu of the towing
expense,Cummins will pay reasonable costs for
mechanics to travel to and from the location of the
vehicle,including meals,mileage and lodging when
the repair is performed at the site of the failure.
Owner
Responsibilities
Owner is responsible for the operation and
maintenance of the Engine as specified in Cummins
Operation and Maintenance Manuals.Owner is also
responsible for providing proof that all recommended
maintenance has been performed.
Before the expiration of the applicable Warranty,
Owner must notify a Cummins distributor,authorized
dealer or other repair location approved by Cummins
of any Warrantable Failure and make the Engine
available for repair by such facility.Except for Engines
disabled by a Warrantable Failure,Owner must also
deliver the Engine to the repair facility.
Service locations are listed on the Cummins Worldwide
Service Locator at cummins.com.
Owner is responsible for the cost of lubricating oil,
antifreeze,filter elements and other maintenance items
provided during Warranty repairs unless such items
are not reusable due to the Warrantable Failure.
Owner is responsible for communication expenses,
meals,lodging and similar costs incurred as a result of
a Warrantable Failure.
Owner is responsible for non-Engine repairs and for
‘‘downtime’’expenses,cargo damage,fines,all
applicable taxes,all business costs and other losses
resulting from a Warrantable Failure.
Owner is responsible for a $100 (U.S.Dollars)
deductible per each service visit under this plan in the
3rd,4th and 5th years of Base Engine Warranty.The
deductible will not be charged during the first 2 years
of the Base Engine Warranty.
Limitations
Cummins is not responsible for failures or damage
resulting from what Cummins determines to be abuse
or neglect,including,but not limited to:operation
without adequate coolants or lubricants;overfueling;
overspeeding;lack of maintenance of lubricating,
cooling or intake systems;improper storage,starting,
warm-up,run-in or shutdown practices;unauthorized
modifications of the Engine.
Any unauthorized modifications to the aftertreatment
could negatively effect emissions certification and void
Warranty.
Cummins is also not responsible for failures caused by
incorrect oil,fuel or diesel exhaust fluid or by water,
dirt or other contaminants in the fuel,oil or dieselPROPOSAL NO. 81217-18
exhaust fluid.
This Warranty does not apply to accessories supplied
by Cummins which bear the name of another
company.Such non-warranted accessories include,but
are not limited to:alternators,starters,fans,air
conditioning compressors,clutches,filters,
transmissions,torque converters,vacuum pumps,
power steering pumps,fan drives and air compressors.
Cummins branded alternators and starters are covered
for the first two years from the date of delivery of the
Engine to the first user,or the expiration of the Base
Engine Warranty,whichever occurs first.
Failures resulting in excessive oil consumption are not
covered beyond the duration of the Coverage or
100,000 miles (160,935 kilometers)or 7,000 hours from
the date of delivery of the Engine to the first user,
whichever of the three occurs first.Before a claim for
excessive oil consumption will be considered,Owner
must submit adequate documentation to show that
consumption exceeds Cummins published standards.
Failures of belts and hoses supplied by Cummins are
not covered beyond the first year from the date of
delivery of the Engine to the first user or the duration
of the Warranty,whichever occurs first.
Parts used to repair a Warrantable Failure may be new
Cummins parts,Cummins approved rebuilt parts or
repaired parts.Cummins is not responsible for failures
resulting from the use of parts not approved by
Cummins.
A new Cummins or Cummins approved rebuilt part
used to repair a Warrantable Failure assumes the
identity of the part it replaced and is entitled to the
remaining Coverage hereunder.
Cummins Inc.reserves the right to interrogate
Electronic Control Module (ECM)data for purposes of
failure analysis.
CUMMINS DOES NOT COVER WEAR OR WEAROUT
OF COVERED PARTS.
CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.
THIS WARRANTY AND THE EMISSION WARRANTY
SET FORTH HEREINAFTER ARE THE SOLE
WARRANTIES MADE BY CUMMINS IN REGARD TO
THESE ENGINES.CUMMINS MAKES NO OTHER
WARRANTIES,EXPRESS OR IMPLIED,OR OF
MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
This Warranty gives you specific legal rights,and you
may also have other rights which vary from state to
state.
Emission
Warranty
Products Warranted
This Emission Warranty applies to new Engines
marketed by Cummins that are used in the United
States**in vehicles designed for transporting persons
or property on a street or highway.This Warranty
applies to Engines delivered to the first user on or after
September 1,1992.
Coverage
Cummins warrants to the first user and each
subsequent purchaser that the Engine is designed,
built and equipped so as to conform at the time of sale
by Cummins with all U.S.federal emission regulations
applicable at the time of manufacture and that it is free
from defects in material or factory workmanship which
would cause it not to meet these regulations within the
longer of the following periods:(A)Five years or
100,000 miles (160,935 kilometers)of operation,
whichever occurs first,as measured from the date of
delivery of the Engine to the first user or (B)The Base
Engine Warranty.
If the vehicle in which the Engine is installed is
registered in the state of California,a separate
California Emission Warranty also applies.
Limitations
Failures,other than those resulting from defects in
material or factory workmanship,are not covered by
this Warranty.
Cummins is not responsible for failures or damage
resulting from what Cummins determines to be abuse
or neglect,including,but not limited to:operation
without adequate coolants or lubricants;overfueling;
overspeeding;lack of maintenance of lubricating,
cooling or intake systems;improper storage,starting,
warm-up,run-in or shutdown practices;unauthorized
modifications of the Engine.
Any unauthorized modifications to the aftertreatment
could negatively effect emissions certification and void
Warranty.
Cummins is also not responsible for failures caused by
incorrect oil,fuel or diesel exhaust fluid or by water,
dirt or other contaminants in the fuel,oil or diesel
exhaust fluid.
Cummins is not responsible for non-Engine repairs,
‘‘downtime’’expenses,cargo damage,fines,all
applicable taxes,all business costs or other losses
resulting from a Warrantable Failure.PROPOSAL NO. 81217-18
Cummins Inc.
Box 3005
Columbus, IN 47202-3005
U.S.A.
Bulletin 3381161
Printed in U.S.A. Rev. 08/09
©2001 Cummins Inc.
CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.
*Airport operated crash trucks and fire department
operated trucks employed to respond to fires,
hazardous material releases,rescue and other
emergency-type situations.
**United States includes American Samoa,the
Commonwealth of Northern Mariana Islands,Guam,
Puerto Rico and the U.S.Virgin Islands.
Cummins Inc.
Box 3005
Columbus,IN 47202-3005
U.S.A.
Bulletin 3381161PrintedinU.S.A.Rev.08/092001CumminsInc.PROPOSAL NO. 81217-18
This limited warranty shall apply only if the product is properly maintained in accordance
with Pierce's maintenance instructions and manuals and is used in service which is normal
to the particular model. Normal service means service which does not subject the product
to stresses or impacts greater than normally result from careful use. If the Buyer discovers
a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the
date of discovery, but in any event prior to the expiration of the warranty period. THIS
LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE TRANSFERRED BY
THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER
PERSON OR ENTITY.
The exclusions listed in the attached Meritor warranty
description shall apply.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and
Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT
(INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW OR
EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY PIERCE,
OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS THEREIN, OR
ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO, REGARDLESS OF
WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH
DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims
any liability for property or personal injury damages, penalties, damages for lost profits or
revenues, loss of vehicles or products or any associated equipment, cost of substitute
vehicles or products, down-time, delay damages, any other types of economic loss, or for
any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty
period, and such nonconformity is not due to misuse, neglect, accident or improper
maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and
shall make the product available for inspection by Pierce or its designated agent. At the
request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for
examination and/or repair. Buyer shall be responsible for the cost of such transportation,
and for risk of loss of or damage to the product during transportation. Within a reasonable
time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or
defective parts. Repair or replacement shall be made only by a facility approved in
advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE
REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced
during the warranty period, including, but not limited to, tires, fluids, gaskets and light
bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into
finishing products or vehicles unless the assembly is performed by Pierce.
Two (2) YearWarranty Period
Ends After:
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty
is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle,
and not to other warranties made by Pierce in a separate document (if any) or to the
warranties (if any) made by any manufacturer (other than Pierce) of any part, component,
attachment or accessory that is incorporated into or attached to the vehicle.
8/22/2017 WA0328
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE
WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING
WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY
OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING
FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is
repaired or replaced (a) without prior written approval of the Pierce Customer Service
Department; or (b) at a facility which has not been approved by Pierce as to technical
capability. Any repairs, modifications, alterations or aftermarket parts added after
manufacture without the authorization of Pierce may void this warranty.
Fire and Rescue Apparatus
Coverage:
Two (2) Year Material and Workmanship
Meritor Axles
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as
to:
The Meritor axle shall be covered by Meritor as indicated in
the attached Meritor warranty coverage description
1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by
misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic
environment, improper maintenance, accident, crash, or force majeure such as natural
disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the
following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been
repaired, altered or assembled in any way by any person or entity other than Pierce which,
in the sole judgment of Pierce, adversely affects the performance, stability or purpose for
which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product
that are not manufactured by Pierce, including but not limited to engines, transmissions,
drivelines, axles, water pumps and generators; with respect to all such parts, components,
attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if
any, made by the respective manufacturers thereof;
The date of the original purchase invoice (issued when the
product ships from the factory).Warranty Begins: PROPOSAL NO. 81217-18
MERITOR® COMMERCIAL
VEHICLE SYSTEMS
WARRANTY/MODEL YEAR 2018 VEHICLES
PROPOSAL NO. 81217-18
Advantage Program
Purchasing additional coverage on select components will continue to safeguard your investment against major repair costs after the initial
base coverage expires. You can find out more about the Advantage Program by visiting www.meritor.com or by contacting Meritor at
866-OnTrac1 (866-668-7221).
2
Linehaul .............................................................................................................3-4
General Service ...................................................................................................5-6
Heavy Service ......................................................................................................7-8
Off-Highway Service ................................................................................................9
Terms and Conditions ............................................................................................10
How to Read Warranty Coverage
Number of Years Mileage (in thousands)
Unl=Unlimited
P=Parts Only
P&L=Parts & Labor
Notice:
Models or components that are approved for use by Meritor’s vocational guidelines contained in Meritor Publication TP-9441 for axles,
SP-8320 for trailer axles, TP-12126 for drivelines, which are not specifically listed, are warranted for one year, unlimited miles, parts
only (1/Unl/P).
Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles parts only (1/Unl/P).
Effective Model Year 2018 Vehicles
WARRANTY INFORMATION CONTENTS
PROPOSAL NO. 81217-18
n Auto Hauler
n Bulk Hauler
n Chip Hauler (Truck)*
n Doubles
n Flatbed
n General Freight
n Grain Hauler
n Livestock Hauler
n Moving Van
n Pipe Hauler
n Refrigerated Freight
n Tanker
n Triples
FD-965
FF-941
FF-942
FF-943
FF-944
FF-961
FF-966
FF-967
FG-941
FG-943
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122A-N
MFS-12-122B-N
MFS-12-122C-N
MFS-12E-122A-N
MFS-12-132B-N
MFS-12-132C-N
MFS-12-143A-N
MFS-12E-143A-N
MFS-12-144A-N
MFS-13-122A-N
MFS-13-122B-N
MFS-13-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-14-122A-N
MFS-14-143A-N
n High mileage operation (over 60,000 miles/year)
n Well maintained major highways of concrete or
asphalt construction
n Greater than 30 miles between starting and stopping
Coverage under Meritor’s warranty require that the application of products be
properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for
axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor
regarding specific application approval questions on any product line.
* Chip Hauler vehicles require specific axle models listed below and Linehaul condition to be eligible for Linehaul warranty consideration.
Linehaul Vehicles
Front Non-Drive Steer Axles – 5/750/P&L
Linehaul Typically Is
RPL 5/500/P, 1/Unl/P&L
MXL 3/350/P, 1/Unl/P&L
155N 1/Unl/P
92N 1/Unl/P
Drivelines
RS-19-144/145/A
MS-19-14X
MS-21-144
RS-21-145
RS-21-160
RS-23-160
RS-23-161
RS-23-186
Rear Drive Single Axles – 5/750/P&L
1 These models required for Chip Hauler and Linehaul warranty consideration.
2 Each vehicle must have a Request for Application Recommendation (RAR)
approved by Meritor prior to vehicle build. All RARs must identify the chassis
number or VIN. Refer to Product Information Letter #303 and #396 for
further details.
RT-34-144/P/A
RT-40-145/A
RT-40-160/P1,2
RT-46-160/P1,2
RT-46-164EH/P1,2
RT-50-160/P1,2
MA-40-165
MA-40-175
MT-34-14X/P
MT-40-14X/P
MT-40-14X/P
MT-40-144/P
MT-40-943
MT-40-943-SP
RZ-1662
RZ-188
Rear Drive Tandem/Tridem Axles – 5/750/P&L
LINEHAUL WARRANTY INFORMATION
3PROPOSAL NO. 81217-18
Cam Q Series Trailer Brakes 5/500/P, 1/100/L
LX500 Feature1 5/750/P&L
Q+ Drum Brake™ 5/500/P, 1/Unl/P&L
ASA 5/500/P, 1/Unl/P&L
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
STEELite X30 Drum Brake™2 12-Years or Wearable Life/P
EX+ Air Disc Brake™ 5/500/P, 1/Unl/L
1 Includes: bushing, seal, cam, ASA lubrication and wear coverage of
3/500/P&L.
2 Based on stamped wear diameter max.
MPA38/40 (Tandem Axle Parallelogram)1
Major Structural Components 5/500/P, 1/100/L
Curbing Damage Warranty2 5/500/P, 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs 2/200/P, 1/100/L
Bushings 7/700/P, 5/500/L
PinLoc Air Controls 1/100/P&L
PinLoc Actuator 3/300/P&L
MPA20 (Single Axle Parallelogram)
Major Structural Components 5/500/P, 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs 2/200/P, 1/100/L
Bushings 7/700/P, 5/500/L
MTA (Trailing Arm)
Major Structural Components 5/500/P, 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs & Rebound Straps 2/200/P, 1/100/L
Bushings 5/500/P, 3/300/L
1 Fastener torque coverage is limited to 2/Unl P&L when torqued by Meritor
(For axle and ABS coverage, refer to appropriate product warranties.)
2 “Curbing damage” is defined as deformation (bending, buckling, or breakage),
caused by sudden impact with a curb or similar fixed object. Damage to the
RideSentry slider box (the suspension sliding subframe, consisting of the frame
rails, crossmembers, and central A-frame assembly), caused by accidental trailer
impact with a curb or similar fixed object, is eligible for warranty coverage.
Damage to other components or damage resulting from collision with another
vehicle, rollover or fire is not covered under this provision. Warranty is not
transferrable to another trailer VIN, and coverage does not apply if the trailer
is deemed to be a total loss, scrapped, or otherwise not salvageable.
TQ, TQD, TR, TRD Beam and Brackets 5/750/P&L
1 For brake components and ABS Coverage, refer to appropriate product warranties.
MTIS Components 3/500/P&L
Beam and Brackets 5/500/P, 1/100/L
Wheel End Systems1
Standard System2 1/100/P&L
PreSet by Meritor3 5/500/P&L
AxlePak54 5P/L
AxlePak75 7P/L
1 Includes hub, wheel seals and wheel bearings—all systems require annual
inspections and proper documentation to ensure full coverage.
2 When installed by Meritor.
3 Requires approved hubcap stating PreSet by Meritor on hubcap face.
4 When specified with AxlePak5 wheel end system, coverage on MTIS thru-tee and
stator is 5/500P, 3/500L.
5 When specified with AxlePak7 wheel end system, coverage on MTIS thru-tee
and stator is 7/750P, 3/500L.
(For brake components and ABS coverage, refer to appropriate
product warranties.)
Brake Components Trailer Air Suspension Systems
TAG/Pusher Axles1
Meritor Tire Inflation System by PSI
Trailer Axles
4
LINEHAUL WARRANTY INFORMATION
PROPOSAL NO. 81217-18
n Aerial Ladder Truck
n Aerial Platform
n Ambulance
n Auto Hauler
n Beverage Truck
n Chip Hauler
n Cross Country Coach
n Flatbed
n Front Engine Commercial Chassis
n Front Engine Integral Coach
n General Freight
n Intercity Coach
n Intermodal Chassis
n Livestock Hauler
n Meat Packer
n Moving Van
n Municipal Truck
n Newspaper Delivery
n Pick-Up and Delivery
n Pipe Hauler
n Platform Auto Hauler
n Pumper
n Rear Engine Integral Coach
n Recreational Vehicles
n Refrigerated Freight
n School Bus
n Stake Truck
n Tanker
n Tanker Truck
n Tour Bus
n Wrecker
FD-965
FF-941
FF-942
FF-943
FF-944
FF-946
FF-961
FF-966
FF-967
FG-941
FH-941
FH-9461
FL-941
FL-943
MFS-6-151A-N
MFS-6-153B-N
MFS-6-162B-N
MFS-6-153C-N
MFS-6-162C-N
MFS-7-113C-N
MFS-7-153C-N
MFS-7-163C-N
MFS-8-113B-N
MFS-8-143A-N
MFS-8-153B-N
MFS-8-163B-N
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122A-N
MFS-12E-122A-N
MFS-12-122B-N
MFS-12-122C-N
MFS-12-132B-N
MFS-12-132C-N
MFS-12-143A-N
MFS-12-144A-N
MFS-12E-143A-N
MFS-13-122A-N
MFS-13-122B-N
MFS-13-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-14-122A-N
MFS-14-143A-N
MFS-16-122A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20H-193A-N
MFS-22H-135A-N
MFS-22H-193A-N
n Lower mileage operations (less than 60,000 miles/year)
n Generally, on-road service (less than 10% off-road)
n An average of three (3) miles between starting and stopping
Coverage under Meritor’s warranty require that the application of products be
properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for
axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor
regarding specific application approval questions on any product line.
RT-40-160/P
RT-46-160/P
RT-46-164EH/P
RT-50-160/P
General Service Vehicles
Front Drive/Non-Drive Steer Axles – 2/Unl/P&L
General Service Typically Is
Rear Drive Tandem – 3/Unl/P&L
RPL 4/400/P, 1/Unl/P&L
MXL 3/350/P, 1/Unl/P&L
155N 1/Unl/P
92N 1/Unl/P
Drivelines
MS-17-13X
MS-17-14X
MS-19-13X
MS-19-14X
RS-17-144/145/A
RS-19-144/145/A
MS-21-13X
MS-21-14X
MS-21-144
MS-23-17X
RS-21-145/A
RS-21-160
RC-22-145
RC-22-145/A
RC-23-160
RC-23-161
RC-23-1621
RC-23-1651
RS-23-160
RS-23-161
RS-23-186
RS-24-160
RC-25-160
RS-26-185
MS-26-616
MS-26-616-SP
RS-30-185
MS-30-616
MS-30-616-SP
RS-35-380
71162
71163
79163
Rear Drive Single Axles – 2/Unl/P&L
1 3/Unl/P&L if PreSet by Meritor.
MT-34-14X/P
RT-34-144/P/A
MT-40-14X/P
MT-40-144/P
RT-40-145/A
MT-44-14X/P
RT-44-145/P
RT-46-169
MT-52-616
RT-52-1851
MT-58-616
RT-58-1851
MT-70-380
RZ-166
RZ-188
Rear Drive Tandem/Tridem Axles – 2/Unl/P&L
1 Each vehicle must have a Request for Application Recommendation (RAR) approved by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN.
Refer to Product Information Letter #303 and #396 for further details.
GENERAL SERVICE WARRANTY INFORMATION
1 Can also be used with reduced steer angles in tag position in Coach Applications.
5PROPOSAL NO. 81217-18
Cam Q Series Trailer Brakes 3/Unl/P, 1/Unl/L
LX500 Feature1 3/Unl/P&L
Cam P3 2/200/P
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
Q+ Drum Brake ™3 2/200/P&L
ASA 3/Unl/P
ASA3 2/200/P
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
STEELite X30 Drum Brake™2 12-Years or Wearable Life/P
EX+ Air Disc Brake™ 2/Unl/P&L
1 Includes: bushing, seal, cam, ASA lubrication and wear coverage of 1/Unl/P.
2 Based on stamped wear diameter max.
3 Applies to Tour Bus and Cross Country Coach only.
Beam and Brackets1 5/Unl/P, 1/Unl/L
Wheel End Systems2
Standard System3 1/Unl/P&L
AxlePak54 5P/L
AxlePak75 7P/L
1 9000 Series is 3/Unl/P, 1/Unl/L
2 Includes hub, wheel seals and wheel bearings—all systems require annual
inspections and proper documentation to ensure full coverage.
3 When installed by Meritor.
4 When specified with AxlePak5 wheel end system, coverage on MTIS thru-tee and
stator is 5/500P, 3/500L.
5 When specified with AxlePak7 wheel end system, coverage on MTIS thru-tee
and stator is 7/750P, 3/500L.
(For brake components and ABS coverage, refer to appropriate
product warranties.)
Beam & Brackets 6/Unl/P, 1/Unl/L
Wheel End Systems1
Standard System 1/Unl/P&L
AxlePak7 7P/L
Beam and Brackets 7P/1L
1 Includes hub, wheel seals and wheel bearings—all systems require annual
inspections and proper documentation to ensure full coverage.
MPA38/40 (Tandem Axle Parallelogram)1
Major Structural Components 5/Unl/P, 1/Unl/L
Curbing Damage Warranty2 5/500/P, 1/100/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P, 1/Unl/L
Bushings 7/700/P, 5/500/L
PinLoc Air Controls 1/Unl/P&L
PinLoc Air Actuator 3/Unl/P&L
MPA20 (Single Axle Parallelogram)
Major Structural Components 5/Unl/P, 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P, 1/Unl/L
Bushings 7/700/P, 5/500/L
MTA (Trailing Arm)
Major Structural Components 5/Unl/P, 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs and Rebound Straps 2/Unl/P, 1/Unl/L
Bushings3 5/Unl/P, 3/Unl/L
(For axle and ABS coverage, refer to appropriate product warranties.)
1 Fastener torque coverage is limited to 2/Unl P&L when torqued by Meritor
2 “Curbing damage” is defined as deformation (bending, buckling, or breakage),
caused by sudden impact with a curb or similar fixed object. Damage to the
RideSentry slider box (the suspension sliding subframe, consisting of the frame
rails, crossmembers, and central A-frame assembly), caused by accidental trailer
impact with a curb or similar fixed object, is eligible for warranty coverage.
Damage to other components or damage resulting from collision with another
vehicle, rollover or fire is not covered under this provision. Warranty is not
transferrable to another trailer VIN, and coverage does not apply if the trailer
is deemed to be a total loss, scrapped, or otherwise not salvageable.
3 Raw wood applications 3/Unl/P, 1/Unl/L
MTIS Components 3/500/P&L
TQ, TQD, TR, TRD Beam and Brackets1 3/Unl/P, 1/Unl/L
MC12002, MC14002, MC16003, FH946 2/Unl/P&L
(For brake components and ABS coverage, refer to appropriate
product warranties.)
1 3/UNL/P&L if sold with PreSet by Meritor.
Brake Components
Trailer Axles
Chassis Axles (2000 Series/ChassiPak)
Trailer Air Suspension Systems
Meritor® Tire Inflation System by PSI
TAG/Pusher Axles
6
GENERAL SERVICE WARRANTY INFORMATION
PROPOSAL NO. 81217-18
Heavy Service Vehicles
n Airport Rescue Fire (ARF)
n Airport Shuttle
n Asphalt Truck
n Block Truck
n Bottom Dump Trailer
Combination
n Cementing Vehicle
n City Bus
n Commercial Pick-Up
n Concrete Pumper
n Construction Material Hauler
n Crash Fire Rescue (CFR)
n Mixer
n Demolition
n Drill Rig
n Dump
n Emergency Service
n Equipment Hauling
n Flatbed Trailer Hauler
n Flatbed Truck
n Fracturing Truck
n Front Loader
n Geophysical Exploration
n Hopper Trailer Combinations
n Landscaping Truck
n Liquid Waste Hauler
n Log Hauling
n Lowboy
n Michigan Special Gravel Trains
n Michigan Special Log Hauler
n Michigan Special Steel Hauler
n Michigan Special Waste Vehicle
n Municipal Dump
n Rapid Intervention Vehicle (RIV)
n Rear Loader (Refuse)
n Recycling Truck
n Residential Pick-Up (Refuse)
n Rigging Truck
n Roll-Off
n Scrap Truck
n Semi-End Dump
n Sewer/Septic Vacuum
n Shuttle Bus
n Side Loader
n Snowplow/Snowblower
n Steel Hauling
n Tanker
n Tank Truck
n Tractors with Pole Trailers
n Tractor/Trailer with Jeeps
n Transfer Dump
n Transfer Vehicle
n Transit Bus
n Trolley
n Utility Truck
n Winch Truck
n Moderate mileage operation (less than 60,000 miles per year)
n On/Off road vocations (10% or more off-road)
n Moderate to frequent stops/starts (up to 10 stops per mile)
Coverage under Meritor’s warranty require that the application of products
be properly approved pursuant to OEM and Meritor approvals. Refer to
TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/
or contact Meritor regarding specific application approval questions on any
product line.
Heavy Service Typically Is
FD-965
FF-941
FF-942
FF-943
FF-944
FF-946
FF-961
FF-966
FF-967
FG-941
FG-943
FH-941
FH-946
FL-941
FL-943
MFS-6-151A-N
MFS-6-153B
MFS-6-162B
MFS-6-162C
MFS-7-113C-N
MFS-7-153C-N
MFS-7-163C-N
MFS-8-113B-N
MFS-8-153B-N
MFS-8-163B-N
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122
MFS-12-122B-N
MFS-12-122C-N
MFS-12E-122
MFS-12-132B-N
MFS-12-132C-N
MFS-12-143A-N
MFS-12-144A-N
MFS-12-155
MFS-13-122
MFS-13-122B-N
MFS-13-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-13-155
MFS-14-122
MFS-14-143A-N
MFS-16-122A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20H-193A-N
MFS-22H-135A-N
MFS-22H-193A-N
RF-16-145
RF-21-160
MX-10-120
MX-10-120 EVO
MX-12-120
MX-12-120 EVO
MX-14-120
MX-16-120
MX-18-120
MX-17-140
MX-19-140
MX-21-140
MX-21-160
MX-23-160
MX-810
MS-17-14X
RS-17-144/145/A
MS-19-14X
RS-19-144
MS-21-114
MS-21-14X
RS-21-145
RS-21-145/A
RS-21-160
RC-22-145
RC-23-160
RH-23-160
RS-23-160
RC-23-161
RS-23-161
RS-23-186/380
RC-23-162
RC-23-165
RS-24-160
RS-25-160
MS-26-616
MS-26-616-SP
RS-26-185/380
MS-30-616
MS-30-616-SP
RS-30-185/380
MS-35-380
RS-38-380
RC-25-160
RC-26-633
MT-58-616
MT-58-616-SP
71162
71163
79163
Front Drive/Non-Drive Steer Axles – 2/Unl/P&L
Rear Drive Single Axles – 2/Unl/P&L
RPL 3/Unl/P, 1/Unl/P&L
92N 1/Unl/P&L
MXL 1/Unl/P&L
Drivelines
HEAVY SERVICE WARRANTY INFORMATION
7PROPOSAL NO. 81217-18
MT-34-14X/P
RT-34-144/P/A
MT-40-14X/P
RT-40-145/A
MT-44-14X/P
RT-44-145/P
RT-46-169
MT-52-616
MT-52-616-SP
RT-52-185/3801,2
MT-58-616
MT-58-616-SP
RT-58-185/3801,2
RT-70-380
MT-70-380
RZ-166
RZ-188
Cam P 3/Unl/P
Cam P3 2/100/P
Cam Cast Plus™ 2/100/P&L
Q+ Drum Brake™ 3/Unl/P&L
Q+ Drum Brake™2 2/100/P&L
ASA 3/Unl/P
ASA2 2/100/P
Hubs/Cast Drums and
Other Wheel-end
Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake 2/100/P&L
1 Based on stamped wear diameter max.
2 Applies to City Bus, Trolley, Shuttle Bus and Airport
Shuttle only.
3 Warranty for all non-Meritor ASAs supplied by
Meritor for all Heavy Service vocations is 1/100/P.
RT-40-160/P/A3
RT-46-160/P/A1,3
RT-46-164EH/P/A2,3
RT-50-160/P/A3
1 U.S. only. Canadian warranty = 1/Unl/P for
combination vehicles only.
2 Axle model designated will vary according to options
and variations specified on these axles. Contact
Meritor Axle Applications Engineering for details.
3 Each vehicle must have a Request for Application
Recommendation (RAR) approved by Meritor prior
to vehicle build. All RARs must identify the chassis
number or VIN. Refer to Product Information Letter
#303 and #396 for further details.
MTA (Trailing Arm)
Major Structural Components1 5/Unl/P, 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P, 1/Unl/L
Bushings1 5/Unl/P, 3/Unl/L
1 Raw wood applications 3/Unl/P, 1/Unl/L
(For axle and ABS coverage, refer to appropriate
product warranties.)
MTC-4208
MTC-4210
MTC-4213
T-2111
T-2119
MTIS Components 3/500/P&L
MC26000
71063
79063
Beam and Brackets1 5/Unl/P, 1/Unl/L
Wheel End Systems2
Standard System3 1/Unl/P&L
1 9000 Series is 3/Unl/P, 1/Unl/L.
2 Includes hub, wheel seals and wheel bearings—all
systems require annual inspections and proper
documentation to ensure full coverage.
3 When installed by Meritor.
(For brake components and ABS coverage,
refer to appropriate product warranties.)
1 Axle model designated will vary according to options and variations specified on these axles. Contact Meritor Axle Applications Engineering for details.
2 Each vehicle must have a Request for Application Recommendation (RAR) approved by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN.
Refer to Product Information Letter #303 and #396 for further details.
Rear Drive Tandem/Tridem Axles – 2/Unl/P&L
Brake Components Rear Drive Tandem – 3/Unl/P&L Trailer Air Suspension Systems
Transfer Cases – 1/Unl/P
Meritor Tire Inflation System
by PSI
Center Non-drive Axles –
2/Unl/P&L
Trailer Axles
8
HEAVY SERVICE WARRANTY INFORMATION
PROPOSAL NO. 81217-18
Industrial And Off-Highway Service Vehicles
n Load-On/Load-Off
n Port Tractor
n Rail Yard Spotter
n Roll-On/Roll-Off
n Stevedoring Tractor
n Trailer Spotter
n Yard Jockey
n All-Terrain Crane
n Rough Terrain Crane
n Forestry
n Material Handling
n Specialized Heavy Haul
n Specialized Mining
n Excavator
n Compactor
n Fertilizer Spreader
n Snow Blower
n Mining
n Rail Car Mover
n Loader
n Tow Tractor
n Pushback Tractor
n Low mileage operation
n Low speed vehicle speed restriction
n Vehicles are not typically licensed for highway use
n Six (6) starts/stops per mile (typical)
Coverage under Meritor’s warranty require that the application of products be
properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for
axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application
approval questions on any product line.
MOR MOX MOC RPL MXL
MOR MOX MOC MOT
Cam P 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
ASA 3/Unl/P
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
FF - 941
FF - 943
FF - 961
FF - 966
FG - 941
FG - 943
FL - 941
FL - 943
MFS-12-143A-N
MFS-12-144A-N
MFS-13-143A-N
MFS-13-144A-N
MFS-14-143A-N
MFS-16-122A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20H-193A-N
MFS-22H-135A-N
MFS-22H-193A-N
MON-Z0 FAMILY
MT-44-14X/P
MT-52-616
MT-52-616-SP
MT-58-616
MT-58-616-SP
MT-70-380
RT-44-145/P
RT-46-160/P
RT-46-164EH/P
RT-50-160/P
RZ-166
RS-23-186
RS-23-380
RS-24-160
RS-24-160-SP
MS-30-616
MS-30-616-SP
RS-30-185
RS-30-380
MS-35-380
Industrial And Off-Highway Service Typically Is
Drive Steer Axles – 1/Unl/P Drivelines – 1/Unl/P
Planetary Axles – 1/Unl/P
Brake Components
Front Non-Drive Steer Axles – 1/Unl/P Rear Drive Tandem Axles – 2/Unl/P
Rear Drive Single Axles – 1/Unl/P
OFF-HIGHWAY SERVICE WARRANTY
INFORMATION
9PROPOSAL NO. 81217-18
Coverage Exclusions
Product Description
All
The cost of any repairs, replacements or adjustments to a covered
component (1) associated with noise; (2) resulting from the use
or installation of non-genuine Meritor components or materials;
(3) due to vibration associated with improper operation or
misapplication of drivetrain components; and (4) damage
resulting from corrosion.
For axle assemblies supplied by Meritor with suspension and in-
terface brackets designed and/or attached by non-Meritor parties,
Meritor warranty coverage does not apply to the brackets, bracket
attachment methods, and field issues caused by brackets or
bracket attachments to any covered component unless specified
in a separate OEM agreement.
Front Axles
King Pin Bushings.
Rear Axles
Self-contained traction equalizers and oil filters. The use of
NoSPIN differentials will result in the exclusion of axle shafts
from warranty considerations. NoSPIN is a product of Eaton.
ASA
Boot and bushing. Bent, broken, over-torqued, missing or
otherwise damaged pawl assemblies.
Cam Brake
Brake lining wear and brake shoe “rust-jacking.”
Disc Brake
Pad wear, rotor wear.
Coverage Limitations
Product Description
All
Any claim beyond 60 days from date of repair will not be accepted
or honored under this warranty program. Products purchased on
an incomplete vehicle (glider) are limited to one year, unlimited
miles parts only (1/Unl/P).
Front Axles
Tie rod and tie rod ends limited to 3-year/300,000-mile or
published vocational coverage, whichever is less. Wheel seals,
gaskets and wheel bearings are covered for 1 year/unlimited miles
if the wheel end equipment is supplied and assembled by Meritor.
Rear Axles
Pinion and through shaft seals limited to 3-year/300,000-mile
or published vocational coverage, whichever is less, if yoke is
installed by Meritor. If yoke is not installed by Meritor, then
Meritor does not warrant pinion seals. Wheel seals, gaskets and
wheel bearings are covered for 1 year/unlimited miles if the
wheel end equipment is supplied and assembled by Meritor.
Rear Axles
The Meritor® breather part number A-2297-C-8765 with
A-3196-J-1336 hose must be used for eligibility of any potential
warranty consideration relating to contamination and/or loss
of lube in axles.
Cam Brake
Limited to bracket, brake spider and camshaft structural integrity.
STEELite X30
Wearable life is up to the discard diameter of the drum.
Disc Brake
Warranty coverage for boots, seals, bushings and pins is 2/200/P.
Warranty coverage for pads is 1/100/P.
Warranty coverage on vehicles with 1,850 lb-ft engine torque and
over may be reduced on individual drivetrain components. Contact
your Meritor representative for specific details.
10
TERMS AND CONDITIONS
PROPOSAL NO. 81217-18
For more information:
call Ontrac at 866-668-7221
or visit meritor.com
©2017 Meritor, Inc.
Litho in USA, SP-95155
Revised 01-17 (47865/11900)
Meritor Heavy Vehicle Systems, LLC
2135 West Maple Road
Troy, Michigan 48084 USA
Vehicle models, brands and names depicted herein are the property of their respective owners, and are not in any way associated with Meritor, Inc., or its affiliates.
TERMS AND CONDITIONS
(1) What is Covered by this Commercial Warranty?
Meritor Inc. warrants to the owner (“Owner”) that the components
listed in this publication, which have been installed by an Original
Equipment Manufacturer (“OEM”) as original equipment in vehicles
licensed for on-highway use, will be free from defects in material and
workmanship. This warranty coverage begins only after the expiration
of the OEM’s vehicle warranty for the applicable covered components.
Warranty coverage ends at the expiration of the applicable time
period from the date of vehicle purchase by the first Owner, or, the
applicable mileage limitation, whichever occurs first. Duration of
coverage varies by component and vocation as detailed elsewhere in
this warranty statement.
Some components are warranted for parts only and the Owner must
pay any labor costs associated with the repair or replacement of the
component. Other components are warranted for both parts and
reasonable labor to repair or replace the subject component.
Components (whether new, used or remanufactured) installed as re-
placements under this warranty are warranted only for the remainder
of the original period of time or mileage under the original warranty.
For certain components, coverage requires the use of specific
extended drain interval or synthetic lubricants. For further information
about lubrication and maintenance, see Meritor publication
Maintenance Manual Number l and the applicable Meritor
maintenance manual for the product in question. Other conditions
and limitations applicable to this warranty are detailed below.
(2) Designation of Vocational Use Required.
To obtain warranty coverage, each Owner must notify Meritor through
the OEM new truck and/or trailer dealer of the intended vocational
use of the vehicle into which the Meritor components have been
incorporated prior to the vehicle in-service date. This notification
may be accomplished by registering the vehicle through your OEM new
truck and/or trailer dealer or with Meritor directly. Failure to
notify Meritor of (I) the intended vocational use of the vehicle or (II)
a change in vocational use from that which was originally designated,
will result in the application of a one year, unlimited mileage, parts
only warranty (1/Unl/P) from the initial in-service date.
A second Owner and each subsequent Owner must also notify Meritor
as to the intended vocational use of the vehicle. This notification can
be sent directly to Meritor or through the OEM new truck and/or trailer
dealer. The duration and mileage coverage of this warranty cannot
exceed the coverage extended to the first Owner after his or her initial
designation of vocational use.
Coverage under Meritor’s warranty requires that the application of
products be properly approved pursuant to OEM and Meritor
approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles,
TP-12126 for drivelines, and/or contact Meritor regarding specific
application approval questions on any product line.
(3) What is the Cost of this Warranty?
There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty?
This warranty does not cover normal wear and tear; nor does it cover
a component that fails, malfunctions or is damaged as a result of (I)
improper installation, adjustment, repair or modification (including
the use of unauthorized attachments or changes or modification in
the vehicle’s configuration, usage, or vocation from that which was
originally approved by Meritor), (II) accident, natural disaster, abuse,
or improper use (including loading beyond the specified maximum
vehicle weight or altering engine power settings to exceed the
axle and/or driveline capacity), or (III) improper or insufficient
maintenance (including deviation from approved lubricants, change
intervals, or lube levels). This warranty does not cover any component
or part that is not sold by Meritor. For vehicles that operate full or part
time outside of the United States and Canada, a one year, unlimited
mileage, parts only warranty (1/Unl/P) will apply.
(5) Remedy.
The exclusive remedy under this warranty shall be the repair or
replacement of the defective component at Meritor’s option. Meritor
reserves the right to require that all applicable failed materials are
available and/or returned to Meritor for review and evaluation.
(6) Disclaimer of Warranty.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES
OR CONDITIONS, EXPRESSED, IMPLIED OR STATUTORY INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
PARTICULAR PURPOSE.
(7) Limitation of Remedies.
In no event shall Meritor be liable for special, incidental, indirect,
or consequential damages of any kind or under any legal theory,
including, but not limited to, towing, downtime, lost productivity,
cargo damage, taxes, or any other losses or costs resulting from a
defective covered component.
(8) To Obtain Service.
If the Owner discovers within the applicable coverage period a defect
in material or workmanship, the Owner must promptly give notice to
either Meritor or the dealer from which the vehicle was purchased. To
obtain service, the vehicle must be taken to any participating OEM
new truck and/or trailer dealer or authorized Meritor service location.
The dealer will inspect the vehicle and contact Meritor for an evalu-
ation of the claim. When authorized by Meritor, the dealer will repair
or replace during the term of this warranty any defective Meritor
component covered by this warranty.
(9) Entire Agreement.
This is the entire agreement between Meritor and the Owner about
warranty and no Meritor employee or dealer is authorized to make any
additional warranty on behalf of Meritor. This agreement allocates the
responsibilities for component failure between Meritor and the Owner.PROPOSAL NO. 81217-18
CD0135 Air Conditioning - Saber FR - Enforcer.doc 1 11/17/2014
PIERCE MANUFACTURING INC.®
AN OSHKOSH CORPORATION® COMPANY
Certification Document CD0135
Saber® FR - EnforcerTM
Air Conditioning
Pierce Manufacturing certifies the performance of the Saber®FR - EnforcerTM cab air
conditioning system.
The air conditioning system was tested successfully in an environmental chamber.
Air conditioning performance testing was conducted at an ambient of 100°F and 50 percent
relative humidity. The engine speed was maintained at both 1000 and 1400 RPM to simulate
both the Cummins engine and Detroit Diesel engine. Both the QP21 and QP31 compressors
were tested with the controls set to maximum cooling.
The vehicle was heat soaked in the environmental chamber. All temperature probes were
monitored to confirm temperature stabilization. The transient test began when all the vehicle
doors were closed and the air conditioning turned on.
The average cab temperature dropped to a maximum of 73.6°F within 30 minutes in all
configurations.
VALIDATION TEST: RD2455
Pierce Manufacturing, Inc.
David W. Archer
Vice President of Engineering PROPOSAL NO. 81217-18
Oshkosh Corporation Classification: Unrestricted
CD0137 Door Durability - Saber FR - Enforcer 141118.doc 1 11/18/2014
PIERCE MANUFACTURING INC.®
AN OSHKOSH CORPORATION® COMPANY
Certification Document CD0137
Saber®FR – EnforcerTM
Cab Doors
Pierce Manufacturing certifies the integrity of the Saber®FR – EnforcerTM cab doors.
Specimens representing the substantial structural configuration of the Saber®FR – EnforcerTM
cab front and crew doors have been successfully tested to meet the following objectives:
OBJECTIVES:
Survive a 200,000-cycle door slam test with a slam acceleration up to 20 g’s on one
representative
Validate the assembly concept of the main structure of the door by evaluating the
durability of the bonding technique.
Evaluate components, structure, and mounting of the door during and the end of the
test for fatigue and failure to ensure durability.
Verify that the door seals function properly at the end of the test.
Evaluate the new extrusions and castings of the cab doorframe during and at the end of
the test for fatigue, failure, and deformation of seal flanges.
Evaluate various mounting options for the electronic control module for durability during
portions of the slam test.
CONCLUSIONS:
The door structure and doorframe successfully completed a 200,000-cycle door slam
test with a door slam acceleration of 20 g’s.
VALIDATION TEST: RD2425
Pierce Manufacturing, Inc.
David Archer
November 18, 2014 PROPOSAL NO. 81217-18
CD0133 Window Regulators - Saber FR - Enforcer .doc 1 11/17/2014
PIERCE MANUFACTURING INC.®
AN OSHKOSH CORPORATION® COMPANY
Certification Document CD0133
Saber® FR – EnforcerTM
Window Regulators
Pierce Manufacturing certifies the integrity of the Saber ®FR – EnforcerTM window regulators.
Specimens representing the substantial structural configuration of the Saber®FR – EnforcerTM
window regulators have been successfully tested to meet the following objectives:
OBJECTIVES:
Electric window regulators withstand 30,000 up-down cycles.
CONCLUSIONS:
The electric window regulators withstood 30,000 cycles without failure.
VALIDATION TEST: RD2425
Pierce Manufacturing, Inc.
David Archer
Vice President of Engineering
PROPOSAL NO. 81217-18
CD0131 Heat and Defrost - Saber FR - Enforcer .doc 1 11/17/2014
PIERCE MANUFACTURING INC.®
AN OSHKOSH CORPORATION® COMPANY
Certification Document CD0131
Saber® FR – EnforcerTM
Cab Heater & Defrost
Pierce Manufacturing certifies the performance of the Saber® FR – EnforcerTM cab heat and
defroster systems.
The Saber®FR - EnforcerTM Heater and Defroster System was tested successfully in an
environmental chamber.
Defrosting
Defroster testing was performed in accordance with SAE J381 Windshield Defrosting Systems
Test Procedure and Performance Requirements-Trucks, Buses, and Multipurpose Vehicles.
This SAE Recommended Practice establishes uniform test procedures and performance
requirements for the defrosting system of enclosed cab trucks, buses, and multipurpose
vehicles. Current engineering practice prescribes that for laboratory evaluation of defroster
systems, an ice coating of known thickness be applied to the windshield and left- and right-
hand side windows to provide more uniform and repeatable test results, even though under
actual conditions such a coating would necessarily be scraped off before driving. The test
condition, therefore, represents a more severe condition than the actual condition, where the
defroster system must merely be capable of maintaining a cleared viewing area.
During the test, the vehicle is cold-soaked to 0º F in a cold chamber. A prescribed layer of ice
is applied to the windshield. The defroster is then run and the advancing melt boundary
marked as the test proceeds.
The SAE prescribed area of the windshield was 100% cleared and the side windows were
75% cleared within the specified 30 minute period.
Start of Test 10 Minutes 30 Minutes PROPOSAL NO. 81217-18
CD0131 Heat and Defrost - Saber FR - Enforcer .doc 2 11/17/2014
Defrost Results
Right Viewed From Outside Left
Heater:
Heater testing was performed using the coolant supply procedures from SAE J381. The
average cab temperature increased 88.3º F from -10º F to 78.3º F within the prescribed 30
minutes. The cab was contained in a cold chamber at -10º F during the duration of the test.
VALIDATION TEST: T5198REP
Pierce Manufacturing, Inc.
David Archer
Vice President of Engineering PROPOSAL NO. 81217-18
CD0134 Seats and Belts - Saber FR - Enforcer .doc 1 11/17/2014
PIERCE MANUFACTURING INC.®
AN OSHKOSH CORPORATION® COMPANY
Certification Document CD0134
Saber® FR – EnforcerTM
Seats and Seat Belts
Pierce Manufacturing certifies the conformance of the Saber® FR – EnforcerTM cab seats and
seat belts to Federal Motor Vehicle Safety Standards. Representative Saber® FR – EnforcerTM
Seat and Seat Belt designs have been tested successfully in accordance with FMVSS 207.
Physical testing was performed to qualify passenger seats to meet Federal Motor Vehicle
Safety Standards (FMVSS) 207 and 210. This requires that a minimum of 3,000 lbf be applied
to both the lap and shoulder belts via appropriate body blocks. A third force of twenty times
the mass of the seat must be applied at the center-of-gravity (CG) of the seat. All three forces
are applied at the same time, reached within thirty seconds of the start of the test, and be held
for a minimum of ten seconds.
A force equal to twenty times the mass of the seat was applied to each seat in the direction
opposite to the combination pull. A moment of 275 lb-ft was applied to the seat with reference
to the H-point.
This testing ensures that the seat mounting and seat belt anchors are adequate to retain the
seats and occupants in a crash. The Federal requirements are based on the high deceleration
rates of passenger vehicles, so the design requirements are significantly more conservative
considering the slower crash speeds of heavy trucks.
VALIDATION TESTS: RD2397
Pierce Manufacturing, Inc.
David Archer
Vice President of Engineering PROPOSAL NO. 81217-18
CD0132 Windshield Wipers - Enforcer-Saber FR 141117.doc 1 11/18/2014
PIERCE MANUFACTURING INC.®
AN OSHKOSH CORPORATION® COMPANY
Certification Document CD0132
Saber®FR – EnforcerTM
Windshield Wiper System
Pierce Manufacturing certifies the integrity of the Saber® FR –EnforcerTM Windshield Wiper
System.
Specimens representing the configuration of the Saber® FR –EnforcerTM windshield wipers
have been successfully tested to meet the following objectives:
OBJECTIVES:
Complete 3,000,000 cycles of windshield wiper operation per SAE J198 § 6.2
Inspect wiper motor, pivots, linkages, and mounts frequently to validate cumulative
wiper system integrity.
CONCLUSIONS:
The wiper linkage, pivots, and mounts successfully completed the 3,000,000 cycles.
VALIDATION TEST: RD2462
Pierce Manufacturing, Inc.
David Archer
Vice President of Engineering
PROPOSAL NO. 81217-18
CD0130 Cab Integrity Certification - Saber FR - Enforcer .doc 1 11/17/2014
PIERCE MANUFACTURING INC.®
AN OSHKOSH TRUCK CORPORATION® COMPANY
Certification Document CD0130
Saber® FR - EnforcerTM
Cab Integrity Certification
Pierce Manufacturing certifies the integrity of the Saber® FR – EnforcerTM cab relative to
occupant protection.
A specimen representing the substantial structural configuration of the Saber® FR – EnforcerTM
cab models has been successfully tested in accordance with the following standards.
SAE J2422 Cab Roof Strength Evaluation – Quasi-Static Loading Heavy Trucks.
European Occupant Protection Standard ECE Regulation No. 29.
SAE J2420 COE Frontal Strength Evaluation – Dynamic Loading Heavy Trucks.
Side Impact: The test cab was subjected to dynamic preload
where a 14,253 lb moving barrier was slammed into the side of
the cab at 5.25 mph, striking with an impact of 13,000 ft-lbs of
energy. This test is not required to meet the ECE 29 standard,
but is part of the SAE J2422 test procedure and more closely
represents the forces a cab will see in a roll-over incident.
Frontal Impact: The test cab was struck by the 14,253 lb moving
barrier at a speed sufficient to impart the required 32,549 ft-lbs of
energy.
PROPOSAL NO. 81217-18
CD0130 Cab Integrity Certification - Saber FR - Enforcer .doc 2 11/17/2014
Roof Crush: This same test cab was then subjected to a roof
crush force of 24,453 lbs. This value meets the ECE 29 criteria,
which must be equivalent to the front axle rating up to a maximum
of 10 metric tons.
Pass-Fail criteria of the SAE tests and the ECE 29 test is a measure of whether the “survival
space” inside the cab is compromised, all doors remain shut, and the cab remained attached
to the chassis frame in at least one location. The Pierce cab met all of the Performance
Criteria requirements on all 3 integrity tests.
Witnessed and Certified by:
Pierce Manufacturing, Inc.
David Archer
Vice President of Engineering
PROPOSAL NO. 81217-18
CD0156 Vehicle Stability 170601.doc 1 6/26/2017
PIERCE MANUFACTURING INC.®
AN OSHKOSH CORPORATION® COMPANY
Certification Document CD0156
Statement of Compliance to NFPA 1901-2016
Vehicle Stability
Pierce fire apparatus comply with NFPA 1901 Section 4.13 Vehicle Stability using the tilt table method. As prescribed by
the standard, each apparatus is compared to a substantially similar apparatus that has been loaded as required and tested on a
tilt table per the SAE J2180 test procedure. If the apparatus configuration was not expected to meet the minimum tilt table
criteria, then it will be equipped with the Electronic Stability Control option. A listing of all tested apparatus is maintained
by the Research and Development lab and is available for inspection at the Appleton factory.
VALIDATION TEST: Multiple Tests
Pierce Manufacturing, Inc.
David W. Archer
Vice President of Engineering
June 1, 2017 PROPOSAL NO. 81217-18
CD0098 Power Steering System 110623.doc 1 10/14/2014
PIERCE MANUFACTURING INC.®
AN OSHKOSH CORPORATION® COMPANY
Certification Document CD0098
Power Steering System
Pierce Manufacturing, Inc. certifies that the power steering system as installed in our custom
chassis meets the requirements of the component supplier, the NFPA 1901 and NFPA 1906
guidelines as applicable, and Pierce internal design standards.
VALIDATION TEST: RD1987, RD2055
RD2056, RD2057, RD2058, RD2059
Pierce Manufacturing, Inc.
David W. Archer
Director of Engineering
June 03, 2011 PROPOSAL NO. 81217-18
CD0155 Engine - Enforcer L9 GHG17 170601.doc 1 1/17/2018
PIERCE MANUFACTURING INC.®
AN OSHKOSH CORPORATION® COMPANY
Certification Document CD0155
Engine Installation – Enforcer GHG17 Cummins L9 Engine
Pierce Manufacturing, Inc. certifies that the GHG17 Cummins L9 Engine as installed in an
Enforcer chassis meets the engine installation requirements of the engine manufacturer, the
NFPA 1901 and NFPA 1906 guidelines as applicable, and Pierce engine design standards.
Validation testing was conducted in the Pierce wind tunnel chassis dynamometer and cooling
test laboratory. Test results have been reviewed and accepted by representatives of the
engine supplier.
Pierce Manufacturing, Inc.
David W. Archer
Vice President of Engineering
June 5, 2017 PROPOSAL NO. 81217-18
CD0158 Engine - Saber FRL9 GHG17 170605.doc 1 8/16/2017
PIERCE MANUFACTURING INC.®
AN OSHKOSH CORPORATION® COMPANY
Certification Document CD0158
Engine Installation – Saber FR GHG17 Cummins L9 Engine
Pierce Manufacturing, Inc. certifies that the GHG17 Cummins L9 Engine as installed in a
Saber FR chassis meets the engine installation requirements of the engine manufacturer, the
NFPA 1901 and NFPA 1906 guidelines as applicable, and Pierce engine design standards.
Validation testing was conducted in the Pierce wind tunnel chassis dynamometer and cooling
test laboratory. Test results have been reviewed and accepted by representatives of the
engine supplier.
Pierce Manufacturing, Inc.
David W. Archer
Vice President of Engineering
June 5, 2017 PROPOSAL NO. 81217-18
9% sales tax = $5,955.30Total = $72,125.30LITHIA CHRYSLER JEEP DODGE RAM FIAT 4540 GRUMMAN DR, MEDFORD, OR 975049165 Configuration Preview Date Printed: 2018·12·19 8:57 PM VIN: Quantity: Estimated Ship Date: Sold to: LITHIA CHRYSLER JEEP DODGE RAM FIAT (59564) 4540 GRUMMAN DR. MEDFORD, OR 975049165 VON: Status: Ship to: LITHIA CHRYSLER JEEP DODGE RAM FIAT (59564) 4540 GRUMMAN DR. MEDFORD, OR 975049165 BA. Pending order I Vehicle: 2018 5500 CREW CAB CHASSIS 4X4 (173.4 in WB • CA of 60 in) (DP0L93) Sales Code Description -----------·-______ ,. _____ _. __ Model. ------------DPOL93 --5500 CREW CAB CHASSIS 4X4 (173.4 in WB • CA of 60 in) Package: · Paint/Seat/Trim: Options: Destln,atlon Fees: Order Type: Scheduling Priority: 29G Customer Preferred Package 29G ETK 6.7L 16 Cummins Turbo Diesel Engine DF2 6-Spd Auto Aisin AS69RC HD Trans PR4 Flame Red Clear Coat APA Monotone Paint •sx Work Grade Vinyl 40/20/40 Bench Seat -X8 Black/Diesel Gray DK3 Elec Shift-On-The-Fly Transfer Case XAC ParkVlew Rear Back-up Camera RCK CJT UAS XF6 TBB NLL MRU XXJ TUZ XEF YEP XF7 5N6 170 4EX Retail Premium I Speakers Delete Front Center Seat Uconnect 4C with 8.4" Display Voltage Monitoring Auto Idle Up Sys Full Size Spare Tire 52 & 22 Gallon Dual Fuel Tanks Black Tubular Side Steps B-20 Bio Diesel Capability 225/70R19.5G All Traction Tires Transfer Case Skid Plate Shield Mam;f Statement oi Origin Dual Alternators Rated at 440 Amps · Easy Order Zone 70-Phoenix Arizona Sales Tracking HB: FFP: 1,934 60,144 EP: 57,842 PSP Month/Week: 4-Dealer Order Build Priority: Total Price: 99 MSRP(USD) 46,145 4,250 7,745 1,600 0 0 295 0 295 445" 295 -20 1,095 150 350 695 395 0 250 95 0 395 0 0 0 1,695 = Restriction Note: This is not an Invoice, The prices and equipment shown on this priced order confirmation are tentative and subject to chan correction without prior notice. No claims against the content listed or prices quoted wlll be accepted. Refer lo the vehicle Invoice vehicle content and pricing. Orders are accepted only when the vehicle is shipped by the factory.
12/20/2018 IMG_2196.PNG
https://drive.google.com/drive/u/1/folders/11H8SscO1eFTe-vA7TLgUL3q45YCDwL9V 1/1
1
2
3
4
5
6
7
8
9
10
11
12
13
A CASCADE FIRE ~ EQUIPMEHTCOMPANY
P .0 . BOX 4248 •MEDFORD.OREGON 97501
(800) 654-7049 • (541) 779-0394 • Fu (54 1) 779-8847
ulea@cascactefira com · www cascadelra can
ACCOUNT
SHIP TO
•·
12/11/18
1
1
1
1
1
1
1
1
1
1
1
2
1
I
0000936
SAN RAFAEL FIRE DEPT
1600 LOS GAMOS DRIVE
SAN RAFAEL CA
"'" .
085789 ....
EA 24125
EA 11914
EA 24193
EA 11685P
EA 24083•2 ,5P
EA 25012
EA 25013
EA BUMPER
EA FLATBED
EA 0/SBOX
EA PIS BOX
EA U/B BOX
EA INSTALL
A CASCADE FIRE ~ EQUIPMEHTCOMPANY
P .0 . BOX 4248 • MEDFORD, OREGON 97501
I
(800) 654-7049 · (541) 779-0394 · Fax (541) 779-8847
ule:;@c;u,c:wtoficn oom • www cascadolm cqn
Page 1
QUOTE
.. ' ..
1 I Matt I Net 30 . . . .. . .
CFE 300 GALLON END MOUNT UNIT, FULLY BAFFLED POLY
TANK, 2" ALUMINUM FRAME, DI AMOND PLATE TOP &
REAR PLATFORM, ST AJNLESS STEEL PLUMBING ,
STAINLESS STEEL CONTROL PANEL, ELECTRIC PRIMER,
WINTERIZATION SYSTEM 18 200.00 18 200.00
FOAM-PRO 1601 W/ 5 OR 10 GAUON FOAM CELL 5 150.00 5150.00
26HP KUBOTA DIESEL MOTOR WITH HALE PUMP 13 500.00 13 500.00
ALUMINUM ELECTRIC HANNAY REEL W/3/4"X200'
BOOSTER HOSE AND NOZZL E 445.00 445.00
HYDRAN~ 735.00 735.00
INTELUTANK WA AUGE 450.00 450.00
INTELLIT ANK FO UGE 450.00 450.00
BUCKSTOP BUMPER, POWDER COATED BLACK
MANUAL DISCHARGE ON FRONT BUMPER 1.5" 3 300,00 3 300,00
ALUMINUM FLATBED FROM HIGHWAY PRODUCTS 8 550,00 8 550,00
ALUMINUM DIAMOND~ 3 725.00 3 725.00
ALUMINUM DIAMOND P 3 650.00 3 650.00
ALUMINUM 625.00 1 250.00
INSTALL UNIT AT CFE MEDFORD OREGON 1 500.00 1 500.00 . . .
I 0.00 I 5 481.45 I 66 386.45 I
Page 2
CITY OF SAN RAFAEL POLICIES AND PROCEDURES Policv No. Subject: Fleet Manaaement Policy Resolution No. Issue Date: September 6, 2012 Revision Date: Prepared Bv Richard Landis Approved By: ~C-Vl·~ I FLEET MANAGEMENT POLICY AND PROCEDURES PURPOSE: The City of San Rafael establishes this policy to govern the management of the City's vehicle fleet. · SCOPE: The acquisition, outfitting and replacement of all City vehicles. DEFINITIONS: "City vehicle" shall include all automobiles, trucks, motorcycles, or any other equipment registered with the Department of Motor Vehicles and owned, leased, or rented by the City. "Fleet Manager'' shall be the Director of Public Works or his/her designee. POLICY: General Provisions Fleet Manager The role of the Fleet Manager is to advise the City Manager and City Council on matters relating to the City's vehicle fleet. The Fleet Manager shall communicate with all department directors regarding vehicle needs and submit timely reports to the City Manager. The Fleet Manager is committed to the following principles: 1. The size and nature of the City's fleet is governed primarily by need and function, i.e., the number of vehicles should be no greater than what is necessary to provide public services in an efficient manner. Each vehicle within the fleet should be minimally specified to fulfill its intended function, providing operators with a comfortable and modestly-appointed vehicle with which to deliver services in a cost-effective manner. 2. Vehicles should be selected with a strong preference for fuel efficiency and hybrid and alternative fuel technology. The City will strive to reduce the negative impact of its fleet upon the environment by reducing greenhouse gas emissions. 3. Vehicles with the lowest long-term maintenance and repair costs and occupant safety are preferable. Department Budgeting for Additional Vehicle Acquisition Before a department determines the need to add a vehicle to its inventory, it shall first check with the Fleet Manager and the Finance Department to determine whether an existing vehicle is available elsewhere in the fleet that may meet the department's needs. If none is available, the requesting Page 1 of 3
department shall submit a vehicle addition request to the Fleet Manager with the following information: • The purpose for which the vehicle is needed • The type of vehicle requested and the total estimated purchase price • The estimated total cost of any special auxiliary equipment or equipment packages above what might be considered standard equipment. The cost of adding a new vehicle to the fleet shall be paid by the requesting department. Internal service charges to that department's budget shall be established at the time of vehicle purchase to ensure adequate future funding for the vehicle's eventual replacement. Vehicle Acquisition All departments shall submit vehicle purchase requests to the Fleet Manager. The Fleet Manager will consider requests, consult with the Finance Department to ensure that there are sufficient funds for the new vehicle request, and review vehicle specifications for conformance with the provisions and intent of the Fleet Policies and Procedures. All vehicle purchases shall be administered by the Fleet Manager and shall comply with bidding procedures, when applicable, to ensure competitive pricing. Invoices for new vehicle purchases and equipment installation shall be administered by the Fleet Manager with pre-approved departmental account codes established to meet the invoice totals. Vehicle Replacement Funding Funding for vehicle acquisition and supplemental equipment shall be established through monthly internal service charges to the department operating the vehicle, over the projected useable life of that vehicle. An annual inflation factor is applied to the department's internal service charge to account for anticipated increases in future vehicle costs. Vehicle Replacement Schedule City vehicles are eligible for replacement on the basis of the following established useable life recommendations: Vehicle Descriotion Useable Life Sedans, SUV's, vans, liQht and medium duty trucks (up to 8,600 aross vehicle weiQht) 10 years Heavv duty trucks (over 8,600 aross vehicle weight) 15 years Police patrol/traffic vehicles 5 years Police unmarked vehicles 8 years Police motorcycles 4 years Parkina enforcement buaaies 5 years Fire command vehicles 7 years Fire oumoer engines 15 years Fire ladder trucks 20 years Ambulances 5 years Off-road maintenance and construction equipment shall be replaced when economically or operationally justified. When a vehicle in this group approaches the end of its anticipated life cycle, a cost/benefit analysis shall be performed to justify vehicle replacement. Page 2 of 3
These useable life standards are for vehicle replacement financial estimating purposes only. When a vehicle reaches the end of its established useable life and the department operating the vehicle requests replacement, each vehicle shall be assessed by the Fleet Manager and Vehicle Maintenance Division to determine if replacement is justified, given general vehicle condition, mileage, maintenance and repair history, safety considerations, etc. Extension of the useable life of any vehicle shall be at the discretion of the Fleet Manager and the requesting department. Likewise, a department may request a vehicle replacement prior to the end of its established useable life. The Fleet Manager shall review all such requests in consultation with the Finance Department and Vehicle Maintenance Division. Requests for early replacement shall be accompanied by a thorough justification, including objective criteria supporting the request. The cost of early replacement, if any, shall be borne by the requesting department. If a department determines that an assigned vehicle is no longer needed, the vehicle shall be returned to the Vehicle Maintenance Divisio.n for re-allocation within the fleet or disposition as surplus. Disposition of Surplus Vehicles All vehicles accepted by the Vehicle Maintenance Division for replacement or permanent elimination from the fleet shall be consigned to public auction with the City's designated auction service. Departments shall deliver vehicles being replaced to the Vehicle Maintenance Division prior to accepting the new replacement vehicle. Maintenance and Repair of Vehicles Preventive and Routine Maintenance and Repairs The Vehicle Maintenance Division shall notify departments of upcoming scheduled maintenance for vehicles operated by that department and will schedule the date and anticipated duration of the scheduled maintenance. If possible, the department operating the vehicle shall deliver it to the Vehicle Maintenance Division. If necessary, Vehicle Maintenance will pick up the vehicle at its customary parking location and return it when scheduled maintenance is complete. Unscheduled Repairs In the event a vehicle requires immediate or unscheduled repair during normal work hours, operators should call the Vehicle Maintenance Division (458-5345), or take the vehicle to the Public Works facility at 111 Morphew Street for assessment. If the vehicle cannot be operated or is unsafe to operate, the driver should call the Vehicle Maintenance Division for road service, towing, or advice. After normal working hours, vehicle operators should call the non-emergency Police Department dispatch number (485-3000) for towing or road assistance. Vehicle operators must notify their supervisors, as well as the Fleet Maintenance Division, in the event of a vehicle failure. Reimbursement for Personal Expense for City Vehicle Repair Certain emergencies may occur during non-working hours that can be easily remedied at a service station (for example, a flat tire or radiator hose). Department Directors whose employees routinely work outside of normal working hours shall develop appropriate policies governing the authority of vehicle operators to affect emergency repairs during non-working hours with the intended goal of delivering uninterrupted public service. These departmental policies shall be forwarded to the Fleet Manager for reference. Page 3 of 3